XINDUM SM11R4 Smoke Alarm for Home 2 Pack Interlinked Wireless Smoke Detector User Manual
- June 15, 2024
- XINDUM
Table of Contents
XINDUM SM11R4 Smoke Alarm for Home 2 Pack Interlinked Wireless Smoke
Detector
DECLARATION OF CONFORMITY
Hereby, hereby,
- Product name/Product name: SM11.5M11W, SM11R
- Product type: SMOKE DETECTOR conforms with the following safety requirements of the directives 2014/30/EU, 2011 / 305 / EU, 2011 / 65 / EU, 2015 / 863 / EU, 1907 / 2006 / EU. Conformity is guaranteed by the CE symbol.
- This product has been tested against following standards and specifications, applying versions valid in May 2021.
- The full text of the EU Declaration of Conformity is available at the retailer: complies with the following safety requirements of directives 2014 /30 / EU, 2011 /305 / EU, 2011/ 65 / EU, 2015 /863 / EU, 1907 / 2006 /EU. Conformity is guaranteed by the CE symbol.
- This product was tested based on the versions valid in May 2021 using the following standards and Specifications tested.
The full text of the EU Declaration of Conformity is available from the retailer available:
- EN 50130-4:2011
- EN 14604:2005 / AC 2008
- IEC 62321:2020
- EN 61000-6-3:2007+A1
- EN 300 328 V2.2.2:2019
- EN 301 489-1 V2.2.3:2019
- EN 301489-17 V3.2.4:2020
Intended use:
- Fire safety / Essential characteristics: Passed
- Nominal activation conditions/sensitivity/response delay (response time) and performance under fire conditions
- Operating reliability
- Tolerance of supply voltage
- Durability of operational reliability and response delay: Temperature resistance
- Durability of operational reliability : Vibration resistance
- Durability of operational reliability: Humidity resistance
- Durability of operational reliability : Corrosion resistance
- The durability of generational reliability: Electrical stability
Dear Customer,
- Thank you for choosing XINDUM® interlinked Smoke Alarm SM11R4. Hope you have a happy shopping experience in our store.
- As a manufacturer and also a seller on Amazon, we aim to provide high-quality products and the best service to each customer.
- If you have any question or advisement with our products, please write email to us.
- We will do our best to help you and satisfy you.
- Service Email: service@xindian-safety.com
Package Included
- Photoelectric Smoke Alarm
- Mounting Bracket
- Screws & Plugs
- Double-sided Tape User Manual
Product Detail
Power On/Off the Smoke Alarm
- Power On: Long press the power button at the center of the front cover for about 10 seconds until the alarm beeps once and, the red LED indicator flashes once.
- Power Off: Long press the power button for about 10 seconds until the device beeps twice along with the red LED indicator flashes twice.
Device Test
Manual-Test:
- Press the power button once. The smoke alarm beeps 6 times, red indicator flashes 6 times. That means the detector works properly.
- Please test the smoke alarm manually once a week to make sure the device works well (Buzzer test).
Smoke-Test:
- Spread smoke to the detector through the smog entrance.
- A few seconds later, the device beeps once every second until the smoke disappears or manually operates. That means the alarm works properly.
LED Indicator
- Normal Status: Every 60 seconds, the Green LED indicator flashes once.
- Silence Mode: Every 8 seconds, the Red LED indicator flashes once.
- Low Battery: Every 60 seconds, the alarm beeps once, red indicator flashes once.
- Fault Status: Every 40 seconds, the Red LED indicator blinks once, alarm beeps once.
Interlinked Smoke Alarms
- The smoke alarms are interlinked through radio-frequency signals. No matter which alarm detects a fire, all of the linked detectors will alarm.
Linked the Alarms:
- Step 1: Power on all the smoke alarms, select one of the alarms to press the power button four times rapidly. Then the green LED will flash continuously.
- The device is in transmitting mode and lasts for about 60.
- Step 2: Press the power button of the other smoke alarms twice. The Green LED slowly flashes, The devices are in signal-receiving mode.
- If these smoke alarms link successfully, the green LED will stop flashing.
- If failed, the green LED continue flashing 60s, the the red light will be on for 25.
- The devices you received are already interlinked in the factory, just test whether the network is well.
Network Test
Manual Test:
- Select one of the linked alarms, and press the power button. The detector alarms. Then the other linked detectors will alarm too (beeps 6 times, red indicator flashes 6 times).
- That means the detectors are linked successfully.
Smoke-Test:
- Select one of the linked alarms, and spread smoke to the detector through the smog entrance. A few seconds later, the alarm beeps once every second. The other alarms beep 3 times every second. It means all the detectors are linked successfully.
- If one or more alarms do not react, please reconnect it (Refer to ‘F. Interlinked Smoke Alarms’).
Silence Mode
- This function helps you to mute the alarm when alarming.
- Press the power button of the device once, and the alarm of the smoke detector will become inactive for 10 minutes. The red LED flashes once every 8 seconds. After 10 minutes, the Smoke Detector resets. If there is still smoke, the alarm will go off again.
- Before silent the alarm, please identify the reason for causing the alarm and make sure of safe surroundings.
Silent Smoke Alarm Interlinked
- If the smoke alarm detects a fire, it will be a source alarm (beeps once every second) and emits a signal. The other detectors will alarm (beep once every 0.2 seconds) when receive the signal.
- Find out the source alarm and press the power button once to pause all the alarms.
Disconnect the Interlink Function
- Press the power button twice quickly, green LED flashes slowly for about 60. Then the detector will disconnect with other devices.
Installation
Where To Install
Recommended locations:
- Required by law in most countries
- At least one on every floor where people live
- Highly recommended:
- All bedrooms, hallways, and remote rooms
- Extra protection:
- Living room, attic, and basement
DO NOT place the Smoke Detector here:
- Next to air vents, fans, and central heating
- Dusty, dirty areas, areas with insects, and easily polluted places (Garage)
- Places with difficult access (making it difficult to operate the test function)
- Next to doors or windows
- Close to a fireplace or a wood-burning stove
- Areas with high humidity or cooking fumes (Kitchens, bathrooms)
Note:
- If installed on the ceiling, The smoke alarm should be more than 30cm away from the corner. Installed on the wall, 10cm away from the ceiling at least.
- The smoke alarm should be more than 50cm away from the top ceiling when installed in a house with a triangle roof.
Ways To Install
- Two installation ways: Drill and Non-Drill.
Mounting with screw kits
- Step 1 : Twist off the bracket, Mark the location of the screw hole on the wall or ceiling according to the screw hole on the mounting bracket.
- Step 2 : Drill the hole with a 5 mm drill, Insert the dowel into the hole.
- Step 3 : Screw the bracket on the wall or ceiling.
- Step 4 : Attach the detector to the bracket (Align three rotary buckles to the holes) and twist about 5 degrees counterclockwise to lock.
Mounting with double-sided tape
- Step 1 : Peel off the protective film of the tape on one side, and paste it on the bracket.
- Step 2 : Clean the mounting place.
- Step 3 : Peel off the protective film of the tape on the other side, and paste it to the location of installation.
NOTE:
- If the surface has a rough texture, Please install the device with screw kits on Rough walls, plaster ceilings, etc.
Attention
- Please clean the smoke detector once a month at least with the vacuum.
- You can use a stick or broom to press the switch button on the center of the smoke detector.
- DO NOT paint the detector which can influence the accuracy of the alarm.
FAQ
Q: Why doesn’t the alarm ring when testing?
- A: Please check whether the device is powered on.
- The device is in silence mode. Please test it again after 10 minutes.
- Please check whether it is linked to the network with other devices.
Q: The smoke detector beeps every 40 seconds.
- A: There is something wrong with the device. Please turn off the device and clean it with a vacuum. Then restart it. If it still rings, contact us by email. We will solve the problem for you.
Q: Why do smoke alarms often give false alarms?
- A: False alarms can caused by many reasons, such as cooking, smoking, insects, dust, and so on. Don’t install in kitchen, bathroom, places near to the door window and air condition.
- Please select the proper place to install the device to reduce the false alarm (Refer to K-1).
Product Parameters
- Power: DC 3V
- Battery Type: Built-in 2×CR14505 Lithium Battery (Non-replaceable)
- Battery Capacity: 3200mAh
- Operation Current: Standby mode: <30pA, Alarm mode:<70mA
- Alarm Volume: ≥85dB at 3 meters
- Alarm Sensitivity: 0.09-0.17 dB/m
- Low Battery: 2.6:0.1V
- Frequency: 433.92MHz
- Link Distance: up to 100 meters (outdoor open)
- Max Linked Number: 30pcs per group
- Silent Time: About 10 minutes
- Detector Lifespan: 10 Years
- Battery Lifespan: 10 Years (Standby)
- Work Temperature: 0-40°C
- Service Email: service@xindian-safety.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>