BROAN KG7T Series High Efficiency Upflow Horizontal Downflow Gas Owner’s Manual

June 15, 2024
Broan

KG7T Series High Efficiency Upflow Horizontal Downflow Gas

Technical Specifications

  • Product Name: KG7T(AandKSeries)

  • Type: Two-Stage, Fixed Speed High Efficiency Upflow/Horizontal
    and Downflow Gas Furnaces

  • Induced Draft: 80+ AFUE

  • Input: 60,000-140,000 Btuh

Product Usage Instructions

Installation

The high efficiency gas furnace can be installed in the
following locations:

  • Free standing in a utility room
  • Basement
  • Enclosed in an alcove or closet

The rounded corner jacket provides a pleasing appliance
appearance. The product is design certified by CSA for application
in the United States and Canada.

Features and Benefits

  • Dent-free product assurance

  • Works well with taller high SEER coils, making it easier to
    handle

  • Adjustable blower duct temperature at furnace start-up

  • Type ignitor with a 20-year history of reliability

  • Utilizes components with quick-connect fittings for ease of
    use

  • Increases cooling performance when matched with a dedicated
    venting system or common vented with other appliances

  • Dedicated light for flame signal strength and 2 lights in
    combination to indicate all other fault codes

  • Uses captured screws to prevent losing door

  • Up to 1 SEER point efficiency gain in cooling

Gas Furnace Components

Upflow/Horizontal Gas Furnace

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Flame Roll-Out Switch
  5. Flame Sensor
  6. Furnace Control Board
  7. Gas Manifold
  8. Gas Valve
  9. Igniter
  10. Inducer Assembly
  11. Main Air Limit Switch
  12. Motor Choke (3/4 and 1HP only)
  13. Motor Control Board
  14. Motor Control Box
  15. Pressure Switch(s)
  16. Transformer

Downflow Gas Furnace

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Combustion Tube
  5. Flame Roll-Out Switch
  6. Flame Sensor
  7. Furnace Control Board
  8. Gas Manifold
  9. Gas Valve
  10. Igniter
  11. Inducer Assembly
  12. Main Air Limit Switch
  13. Motor Choke (3/4 and 1HP only)
  14. Motor Control Board
  15. Pressure Switch(s)
  16. Transformer

Dimensions

Upflow/Horizontal Series

  • Dimension A: 12
  • Dimension B: 12
  • Dimension C: 15
  • Dimension D: 16

Downflow Series

  • Dimension A: 12
  • Dimension B: 12
  • Dimension C: 15
  • Dimension D: 16

Blower Performance – KG7TA/TK

G7TA/TK-80% AFUE, Two-Stage Gas Furnace

Model Number| Heating Input (Btuh)| Motor Switch Setting| External Static Pressure (in.w.c.)| CFM Rise 0.1 in.w.c.| CFM Rise 0.2 in.w.c.| CFM Rise 0.3 in.w.c.| CFM Rise 0.4 in.w.c.| CFM Rise 0.5 in.w.c.| CFM Rise 0.6 in.w.c.| CFM Rise 0.7 in.w.c.| CFM Rise 0.8 in.w.c.
---|---|---|---|---|---|---|---|---|---|---|---
Notes:| 1. Motor Switch Settings are for heating speeds using HEAT
switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5,
6, 7, & 8.| 2. Two openings are recommended for airflows above 1600 CFM if
the filter(s) is (are) adjacent to the furnace.| 3. Data is shown without filter.| 4. Temperature rises in the table are approximate. Actual
temperature rises may vary.| 5. Temperature rises that are shaded in grey are for reference
only. These conditions are not recommended.

FAQ

Q: Can the gas furnace be installed in a utility room?

A: Yes, the gas furnace can be installed free standing in a
utility room.

Q: What is the warranty for the product?

A: The warranty information is not provided in the user manual.
Please refer to the product documentation or contact customer
support for warranty details.

Q: Are there any specific installation requirements?

A: The gas furnace should be installed according to the
guidelines provided in the user manual. Please refer to the
installation section for detailed instructions.

Q: Can the gas furnace be used in Canada?

A: Yes, the product is design certified by CSA for application
in the United States and Canada.

TECHNICAL SPECIFICATIONS

KG7T(AandKSeries)
TwoStage,FixedSpeed HighEfficiencyUpflow/Horizontal andDownflowGasFurnaces
InducedDraft-80+AFUE Input60,000-140,000Btuh
The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in the United States and Canada.
WARRANTY
­ 10 Year all-parts warranty. ­ 10 Year Quality Pledge to replace the unit if the heat
exchanger fails within the first 10 years of operation, to the original owner. ­ Consumer product registration required for 10 year All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web site listed on the back of this document for warranty details. ­ When registered, this product is upgraded to a limited lifetime heat exchanger warranty.

FEATURESandBENEFITS
· 100%firedandtested:All units and each component
are tested on the manufacturing line. · Best packaging in the industry: Unique corner post
design assures product will arrive to the homeowner dent
free. · LowBoyHeight: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle
and install. · Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger assures a long life. · 30secondblowerdelayatstart-up:Assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds). · 30 second post purge: Increases life of heat
exchanger. · Hotsurfaceignitor: Innovative application of an appliance
type ignitor with a 20 year history of reliability. Utilizes
proven Smartlite® technology. · Color coded wire harness: Designed to fit the
components, all with quick-connect fittings for ease of
service and replacement. · Highstaticblowers: All models equipped with high static
blowers. · 90 second cooling cycle blower-off delay (TDR):
increases cooling performance when matched with a
NORDYNE coil. · FlexiblecategoryIventingsystem: May be vented with
dedicated venting system or common vented with other
category one appliances. · Variablespeedblowerkit: Upgradable to full variable
speed with kit. · LPconvertible:Simple burner orifice and regulator spring
change for ease of convertibility. · Diagnostic lights for easy troubleshooting without
countingflashes:Dedicated light for flame signal strength
and 2 lights in combination to indicate all other fault codes
with easy to recognize states without counting flashes. · Integratedcontrolboard: Incorporates connections for
electronic air cleaner, humidifier and twinning. · Two piece door design: Enhances furnace appear-
ance and uses captured screws to prevent loosing door
screws. · Energy Efficient Brushless DC (ECM) Motor: Gives
up to 1 SEER point efficiency gain in cooling.

GASFURNACECOMPONENTS

10 11 8 6

15 16

9

5

2

7

4

3

1234 5678

1 12
13 14

Upflow/HorizontalGasFurnace

1. Blower Assembly 2. Blower Door Switch 3. Burner Assembly 4. Flame Roll-Out Switch 5. Flame Sensor 6. Furnace Control Board 7. Gas Manifold 8. Gas Valve 9. Igniter 10. Inducer Assembly 11. Main Air Limit Switch 12. Motor Choke (3/4 and 1HP only) 13. Motor Control Board 14. Motor Control Box 15. Pressure Switch(s) 16. Transformer

4 13 2 1
10 3
2

1 2 34 5678

7 14
15 16 11 9
8

12 5

6

DownflowGasFurnace

1. Blower Assembly 2. Blower Door Switch 3. Burner Assembly 4. Combustion Tube 5. Flame Roll-Out Switch 6. Flame Sensor 7. Furnace Control Board 8. Gas Manifold 9. Gas Valve 10. Igniter 11. Inducer Assembly 12. Main Air Limit Switch 13. Motor Choke (3/4 and 1HP only) 14. Motor Control Board 15. Pressure Switch(s) 16. Transformer

DIMENSIONS

D
FRONT BRACE
BOTTOM PANEL

TOP VIEW C

23

FLANGES

19

23 1/2

BOTTOM VIEW

ACCEPTS 4″

TYPE B

VENT PIPE

B

25 3/8
Ø 7/8 HOLE FOR ELECTRIC
4 KNOCKOUTS (BOTH SIDES)

1 5/8 X 3 1/2 HOLE FOR GAS

*TA Model#’s
060-23A1 080-24B1 100-24B1 100-35C1 120-35C1
140-45D1

Dimension Dimension Dimension Dimension

“A”

“B”

“C”

“D”

14 ¼

10 ¾

12

12

17 ½

11 ¾

15

16

21
24 ½

14
15 ¼

19 22

19 23

Ø 7/8 HOLE FOR THERMOSTAT
Ø 7/8 HOLE FOR ELECTRIC

22 1/4
25 21 3/4

29 1/2 22 1/2
22 3/4

1 1/4 23

23 15

28

A

LEFT SIDE

1

1 5/8 X 3 1/2 X 45° HOLE FOR GAS
RIGHT SIDE

34 1/2

KG7TA80+HighEfficiencyUpflow/HorizontalSeries

18 5/8

D
FRONT BRACE
BOTTOM VIEW
Ø 7/8 HOLE FOR ELECTRIC
1 5/8 X 3 1/2 HOLE FOR GAS

TOP VIEW C

23

FLANGES

19

ACCEPTS 4″

TYPE B

B

VENT PIPE

*TK Model#’s
060-23A1 080-24B1 100-24B1 100-35C1 120-35C1
140-45D1

Dimension Dimension Dimension Dimension

“A”

“B”

“C”

“D”

14 ¼

10 ¾

12

12

17 ½

11 ¾

15

16

21
24 ½

14
15 ¼

19 22

19 23

Ø 7/8 HOLE FOR THERMOSTAT
Ø 7/8 HOLE FOR ELECTRIC

22 1/4

25
1 5/8 X 3 1/2 X 45° HOLE FOR GAS

29 1/2 22 1/2

25 3/8

7

28

A

LEFT SIDE

7 RIGHT SIDE

KG7TK80+HighEfficiencyDownflowSeries 3

34 1/2 22 1/2

BLOWERPERFORMANCE-KG7TA/TK

G7TA/TK-80%AFUE,TwoStageGasFurnace

ModelNumber

Heating Input

MotorSwitch Setting

0.1

0.2

ExternalStaticPressure(in.w.c.)

0.3

0.4

0.5

0.6

0.7

0.8

(Btuh) 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise

0000 1000 0 1 0 0 600 74 555 80 510 1 1 0 0 705 63 670 66 635 70 600 74 0 0 1 0 775 57 740 60 705 63 665 67 1 0 1 0 900 49 870 51 835 53 800 56 765 58 730 61 695 64 660 67 0 1 1 0 950 47 920 48 890 50 855 52 825 54 795 56 765 58 730 61 TA/TK-060(C)-A1 60000 1 1 1 0 1000 44 970 46 940 47 910 49 880 51 850 52 820 54 790 56 0 0 0 1 1075 41 1045 43 1015 44 985 45 960 46 925 48 900 49 870 51 1 0 0 1 1110 40 1080 41 1055 42 1025 43 1000 44 975 46 945 47 920 48 0 1 0 1 1170 38 1140 39 1115 40 1090 41 1060 42 1035 43 1010 44 985 45 1 1 0 1 1210 37 1185 38 1160 38 1130 39 1105 40 1080 41 1055 42 1025 43 0 0 1 1 1520 29 1225 36 1200 37 1175 38 1150 39 1120 40 1095 41 1070 42 1 0 1 1 1305 34 1280 35 1255 35 1230 36 1205 37 1180 38 1155 38 1130 39 0 1 1 1 1350 33 1230 36 1305 34 1285 35 1260 35 1240 36 1215 37 1195 37 1 1 1 1 1440 31 1400 32 1365 33 1230 36 1295 36 1255 35 1220 36 1185 38 0000 1000 0100 1 1 0 0 725 82 0 0 1 0 810 73 1 0 1 0 940 63 890 67 845 70 795 75 750 79 700 85 0 1 1 0 990 60 945 63 905 65 860 69 820 72 775 76 735 81 690 86 TA/TK-080(C)-B1 80000 1 1 1 0 1055 56 1015 58 970 61 930 64 890 67 845 70 805 74 760 78 0 0 0 1 1135 52 1095 54 1055 56 1010 59 960 62 930 64 890 67 850 70 1 0 0 1 1185 50 1145 52 1105 54 1065 56 1030 58 990 60 950 62 910 65 0 1 0 1 1250 47 1210 49 1170 51 1135 52 1095 54 1055 56 1020 58 980 60 1 1 0 1 1290 46 1255 47 1220 49 1180 50 1145 52 1110 53 1075 55 1040 57 0 0 1 1 1315 45 1275 46 1240 48 1200 49 1160 51 1120 53 1085 55 1045 57 1 0 1 1 1350 44 1315 45 1280 46 1245 48 1205 49 1170 51 1135 52 1100 54 0 1 1 1 1390 43 1350 44 1315 45 1275 46 1240 48 1200 49 1160 51 1125 53 1 1 1 1 1420 42 1380 43 1345 44 1310 45 1270 47 1235 48 1200 49 1160 51
Notes: 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

4

BLOWERPERFORMANCE-KG7TA/TKContinued

G7TA/TK-80%AFUE,TwoStageGasFurnace

ModelNumber

Heating Input

MotorSwitch Setting

0.1

0.2

ExternalStaticPressure(in.w.c.)

0.3

0.4

0.5

0.6

0.7

0.8

(Btuh)

1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise

0 0 0 0 905 82 890 83 805 92 780 95 1 0 0 0 980 76 930 80 900 82 835 89 820 90 800 93 715 104 670 111 0 1 0 0 1095 68 1015 73 980 76 915 81 895 83 870 85 810 91 765 97 1 1 0 0 1160 64 1100 67 1065 70 1035 72 995 74 940 79 895 83 865 86 0 0 1 0 1230 60 1195 62 1170 63 1110 67 1075 69 1060 70 995 74 970 76 1 0 1 0 1315 56 1275 58 1240 60 1195 62 1160 64 1140 65 1115 66 1075 69 0 1 1 0 1345 55 1310 57 1280 58 1250 59 1220 61 1190 62 1140 65 1115 66 TA100(C)-B1 100000 1 1 1 0 1445 51 1390 53 1350 55 1315 56 1280 58 1250 59 1230 60 1185 63 0 0 0 1 1490 50 1430 52 1420 52 1380 54 1340 55 1310 57 1280 58 1275 58 1 0 0 1 1550 48 1510 49 1475 50 1450 51 1420 52 1375 54 1340 55 1325 56 0 1 0 1 1600 46 1270 58 1540 48 1500 49 1475 50 1445 51 1425 52 1385 53 1 1 0 1 1640 45 1605 46 1570 47 1550 48 1525 49 1490 50 1460 51 1430 52 0 0 1 1 1690 44 1665 44 1630 45 1600 46 1570 47 1550 48 1515 49 1490 50 1 0 1 1 1755 42 1730 43 1680 44 1660 45 1640 45 1610 46 1575 47 1550 48 0 1 1 1 1805 41 1770 42 1740 43 1715 43 1690 44 1655 45 1645 45 1605 46 1 1 1 1 1860 40 1825 41 1790 41 1765 42 1745 42 1710 43 1695 44 1660 45 0 0 0 0 1125 66 1040 71 960 77 1 0 0 0 1205 61 1120 66 1040 71 960 77 0 1 0 0 1305 57 1225 60 1150 64 1070 69 995 74 915 81 1 1 0 0 1430 52 1350 55 1270 58 1190 62 1110 67 1030 72 950 78 865 86 0 0 1 0 1525 49 1450 51 1375 54 1300 57 1225 60 1150 64 1075 69 1000 74 1 0 1 0 1620 46 1540 48 1465 51 1390 53 1315 56 1240 60 1165 64 1090 68 0 1 1 0 1695 44 1620 46 1545 48 1465 51 1390 53 1315 56 1235 60 1160 64 TA/TK-100(C)-C1 100000 1 1 1 0 1770 42 1700 44 1630 45 1555 48 1485 50 1410 53 1340 55 1265 59 0 0 0 1 1875 40 1805 41 1730 43 1655 45 1580 47 1510 49 1435 52 1340 55 1 0 0 1 1905 39 1840 40 1775 42 1710 43 1640 45 1575 47 1510 49 1445 51 0 1 0 1 1980 37 1910 39 1845 40 1780 42 1715 43 1650 45 1580 47 1515 49 1 1 0 1 2025 37 1960 38 1895 39 1830 40 1765 42 1700 44 1635 45 1570 47 0 0 1 1 2085 36 2025 37 1960 38 1900 39 1840 40 1775 42 1715 43 1655 45 1 0 1 1 2135 35 2070 36 2010 37 1945 38 1880 39 1815 41 1750 42 1685 44 0 1 1 1 2200 34 2145 35 2090 35 2035 36 1980 37 1925 38 1870 40 1820 41 1 1 1 1 2280 32 2225 27 2170 34 2115 35 2065 22 2010 37 1955 38 1900 39

Notes: 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

5

BLOWERPERFORMANCE-KG7TA/TKContinued

G7TA/TK-80%AFUE,TwoStageGasFurnace

ModelNumber

Heating MotorSwitch

ExternalStaticPressure(in.w.c.)

Input

Setting

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

(Btuh) 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise

0 0 0 0 1125 79 1040

1 0 0 0 1205 74 1120 79 1040 85

0 1 0 0 1305 68 1225 73 1150 77 1070 83

1 1 0 0 1430 62 1350 66 1270 70 1190 75 1110 80 1030 86

0 0 1 0 1525 58 1450 61 1375 65 1300 68 1225 73 1150 77 1075 83 1000 89

1 0 1 0 1620 55 1540 58 1465 61 1390 64 1315 68 1240 72 1165 76 1090 82

0 1 1 0 1695 52 1620 55 1545 58 1465 61 1390 64 1315 68 1235 72 1160 77

TA/TK-120(C)-C1 120000 1 1 1 0 1770 50 1700 52 1630 55 1555 57 1485 60 1410 63 1340 66 1265 70 0 0 0 1 1875 47 1805 49 1730 51 1655 54 1580 56 1510 59 1435 62 1340 66

1 0 0 1 1905 47 1840 48 1775 50 1710 52 1640 54 1575 56 1510 59 1445 62

0 1 0 1 1980 45 1910 47 1845 48 1780 50 1715 52 1650 54 1580 56 1515 59

1 1 0 1 2025 44 1960 45 1895 47 1830 49 1765 50 1700 52 1635 54 1570 57

0 0 1 1 2085 43 2025 44 1960 45 1900 47 1840 48 1775 50 1715 52 1655 54

1 0 1 1 2135 42 2070 43 2010 44 1945 46 1880 47 1815 49 1750 51 1685 53

0 1 1 1 2200 40 2145 41 2090 43 2035 44 1980 45 1925 46 1870 48 1820 49

1 1 1 1 2280 39 2225 40 2170 41 2115 42 2065 43 2010 44 1955 45 1900 47

0 0 0 0 1395 74 1350 77 1305 79 1260 82 1210 86 1165 89

1 0 0 0 1465 71 1420 73 1375 75 1330 78 1290 80 1245 83 1200 86

0 1 0 0 1555 67 1510 69 1470 71 1425 73 1380 75 1340 77 1295 80 1250 83

1 1 0 0 1625 64 1585 65 1540 67 1500 69 1460 71 1415 73 1375 75 1335 78

0 0 1 0 1690 61 1650 63 1610 64 1570 66 1530 68 1485 70 1445 72 1405 74

1 0 1 0 1760 59 1715 60 1670 62 1625 64 1575 66 1530 68 1485 70 1440 72

0 1 1 0 1835 57 1790 58 1745 59 1695 61 1650 63 1605 65 1555 67 1510 69

TA/TK-140(C)-D1 140000 1 1 1 0 1885 55 1840 56 1790 58 1745 59 1700 61 1655 63 1610 64 1565 66 0 0 0 1 1945 53 1900 55 1850 56 1805 57 1760 59 1710 61 1665 62 1620 64

1 0 0 1 1950 53 1905 54 1860 56 1820 57 1775 58 1735 60 1690 61 1650 63

0 1 0 1 2075 50 2030 51 1990 52 1945 53 1900 55 1855 56 1810 57 1770 59

1 1 0 1 2125 49 2085 50 2040 51 2000 52 1955 53 1910 54 1870 55 1825 57

0 0 1 1 2170 48 2130 49 2090 50 2045 51 2005 52 1965 53 1925 54 1880 55

1 0 1 1 2215 47 2180 48 2140 48 2105 49 2070 50 2035 51 2000 52 1965 53

0111

2225 47 2165 48 2100 49 2040 51

1111

2170 48 2120 49 2065 50

Notes: 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

6

Gas Furnace
Design Series
S = Single Stage T = Two Stage
A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal K = 80% Downflow L = 92.1% / 95.1% Downflow

MODELIDENTIFICATIONCODE
KG 7 T A 080 C 23 B 1

Revision Level

InputHeatingCapacity 060 = 60,000 080 = 80,000 100 = 100,000 120 = 120,000 140 = 140,000

CabinetWidth A = 14.25 B = 17.50 C = 21.00 D = 24.50
CoolingAirflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons V = VSB
C = Standard D = 90+% AFUE Low NOx

SPECIFICATIONS

KG7TA/TK MODELNUMBERS

060C-23A1

Input – Btuh (a)

60,000 / 39,000

Heating Capacity – Btuh AFUE

48,000 / 31,200 80.0

Blower D x W

10 x 6

Motor H.P. – Speed – Type

1/2 BLDC

Motor FLA

6.2

Rated Ext. SP – In. W.C.

0.5

Temperature Rise Range – ºF

25-55

080C-24B1

100C-24B1

100C-35C1

120C-35C1

140C-45D1

80,000 / 52,000 100,000 / 65,000 100,000 / 65,000 120,000 / 78,000 140,000 / 91,000

64,000 / 41,600 80,000 / 52,600 80,000 / 52,600 96,000 / 62,400 112,000 / 72,800

80.0

80.0

80.0

80.0

80.0

11 x 8

11 x 8

11 x 10

11 x 10

11 x 10

1/2 BLDC

1/2 BLDC

3/4 BLDC

3/4 BLDC

1 BLDC

6.2

8.7

8.7

8.7

11.7

0.5

0.5

0.5

0.5

0.5

30-60

30-60

35-65

35-65

40-70

Shipping Weights

115lbs

110lbs

120lbs

125lbs

135lbs

155lbs

All models are 115 V, 60 HZ. Gas connections are 1/2″ N.P.T. AFUE= Annual Fuel Utilization Efficiency

7

ACCESSORIES
Description Fixed speed -to- variable speed “A” Cabinet downflow sub base kit “B”, “C”, “D” Cabinet downflow sub base kit U.S. LP Conversion kit (0 to 10,000 ft.) Canada LP Conversion kit (0 to 4,500 ft.) Bottom return filter 20 per box, “A” cabinet Bottom return filter 20 per box, “B” cabinet Bottom return filter 20 per box, “C” cabinet Bottom return filter 20 per box, “D” cabinet Side return filter kit

KG7TA/TKKITS

SKU 904880 902974 904911 904914 904915 903088 904916 904917 904918 541036

GENERALTERMSOFLIMITEDWARRANTY NORDYNE will furnish a replacement for any part of this product which fails in normal use and service within the first ten years of installation, in accordance with the terms of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.

8000 Phoenix Parkway | O’Fallon, MO 63368-3827

Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (02/2010)

834C-0210 (Replaces 834C-1009)

www.broanhvac.net