BROAN FG7MQ060 Fully Modulating Variable Speed Condensing Owner’s Manual
- June 15, 2024
- Broan
Table of Contents
- BROAN FG7MQ060 Fully Modulating Variable Speed Condensing
- Product Information
- Product Usage Instructions
- Fully Modulating
- WARRANTY
- FEATURES and BENEFITS
- DIMENSIONS
- MODEL IDENTIFICATION CODE
- LOCATION OF FURNACE COMPONENTS
- SPECIFICATIONS
- AIRFLOW DATA
- ACCESSORIES
- GENERAL TERMS OF LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BROAN FG7MQ060 Fully Modulating Variable Speed Condensing
Product Information
- Technical Specifications
- Model: FG7MQ
- Type: Fully Modulating, Variable Speed, Condensing Upflow/Horizontal Gas Furnaces
- Induced Draft: 97.0 AFUE
- Input: 60,000 – 120,000 Btuh
- Features and Benefits
- Modulating heating operation
- 100% fired and tested
- Best packaging in the industry
- 30-second blower delay
- 30-second post purge
- Hot surface igniter
- Color-coded wire harness
- Flexible category IV venting system
- High Static Blowers
- Low Boy Height
- Tubular primary heat exchanger
- 90-second fixed cooling cycle blower-off delay (TDR)
- LP convertible
- Diagnostic lights for easy troubleshooting without counting flashes
- Incorporates integrated control board
- Two-piece door design
- Blower Compartment
- Sealed Vestibule
- iQ Drive Thermostat
- Dimensions
- A: 22 1/4 inches
- B: 28 inches
- C: 23 1/2 inches
Location of Furnace Components
Item | Component Name | Specifications |
---|---|---|
1 | FG7MQ Model Numbers | -060D-VB |
-080D-VC
-100D-VC
-120D-VD
2| Airflow Data| Gas Input Rate (Btuh): 45,000
Target CFM for Selected Circulating Air Temperature Rises
(F):
50: Full – Minimum
55: Full – Minimum
60: Full – Minimum
3| Accessories| Description: FG7MQ Kits
SKU: 212D-0509
Product Usage Instructions
- Installation
- Choose a suitable location for the furnace.
- Ensure proper ventilation and clearance around the unit.
- Connect the flexible category IV venting system.
- Follow the wiring diagram to connect the color-coded wire harness.
- Install the furnace in an up-flow or horizontal configuration based on your needs.
- Secure the two-piece door design.
- Operation
- Set the desired temperature on the iQ Drive Thermostat.
- The modulating heating operation will automatically adjust the furnace output to maintain the desired temperature.
- Maintenance
- Regularly clean or replace the air filters to ensure proper airflow.
- Inspect the blower compartment for any debris or obstructions and clean if necessary.
- Check for any signs of wear or damage on the components and replace them as needed.
- Refer to the user manual for detailed maintenance instructions.
- FAQ
- Q: Can I convert the furnace to use LP gas?
- A: Yes, the FG7MQ model is LP convertible. Refer to the user manual for instructions on how to convert the furnace.
- Q: How do I troubleshoot issues with the furnace?
- A: The furnace has diagnostic lights that make troubleshooting easy. Refer to the user manual for a guide on interpreting the diagnostic lights.
- Q: What is the warranty coverage for this product?
- A: The general terms of the limited warranty can be found on our website at www.broanhvac.net.
Fully Modulating
Fully Modulating, Variable Speed, Condensing Upflow/Horizontal Gas Furnaces Induced Draft – 97.0 AFUE Input 60,000 – 120,000 Btuh
The high-efficiency upflow gas furnace may be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
WARRANTY
- 10-year all-parts warranty.
- 10 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 10 years of operation, to the original owner.
- Consumer product registration required for 10 year
- All Parts Warranty and Quality Pledge within a limited period after the installation. See the current warranty document or visit our consumer website listed on the back of this document for warranty details.
- When registered, this product is upgraded to a limited lifetime heat exchanger warranty.
FEATURES and BENEFITS
- iSEER: Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
- Modulating heating operation Includes: Modulating gas valve from 100% to 50% input in 5% increments. Time proportioning modulation down to 15%. Variable speed inducer and blower.
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures the product will arrive to the homeowner dent-free.
- 30-second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
- 30-second post purge: Increases the life of heat exchanger.
- Color-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system : May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum installation flexibility.
- High Static Blowers: All models are equipped with high static blowers.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger ensure a long life.
- 90-second fixed cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
- LP convertible: Simple burner orifice change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
- Incorporates integrated control board: with connections for electronic air cleaner and humidifier.
- Two-piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and insulated for ultra-quiet operation.
- Sealed Vestibule: Reduces burner and inducer sound levels.
- iQ Drive Thermostat: Provides modulation down to 15% and is required for furnace operation.
DIMENSIONS
*MQ Model #’s| Dimension “A”| Dimension “B”|
Dimension “C”
---|---|---|---
060$-6″| 17 ½| 15 ⅞| 16 ⅛
080$-6#| 21| 19 ⅜| 19 ⅝
100$-6#
120$-6$| 24 ½| 22 ⅞| 23 ⅛
FG7MQ 97+ Modulating Upflow/Horizontal Series
MODEL IDENTIFICATION CODE
LOCATION OF FURNACE COMPONENTS
ITEM | COMPONENT NAME |
---|---|
1. | “LOWER !SSEMBLY |
2. | “LOWER $OOR 3WITCH |
3. | “URNER !SSEMBLY |
4. | &INISH &LANGE |
5. | &LAME 2OLL-/UT 3WITCH |
6. | &LAME 3ENSOR |
7. | &URNACE #ONTROL “OARD |
8. | ‘AS -ANIFOLD |
9. | ‘AS 6ALVE |
10. | )GNITER |
11. | )NDUCER !SSEMBLY |
12. | )NDUCER ,IMIT 3WITCH |
13. | -OTOR #HOKE (# AND $ CABINETS ONLY) |
14. | -OTOR #ONTROL “OARD |
15. | -OTOR #ONTROL “OX |
16. | 0RESSURE 3WITCHES |
17. | 4RANSFORMER |
SPECIFICATIONS
FG7MQ MODEL NUMBERS:| -060D-VB| -080D-VC| -100D-VC|
-120D-VD
---|---|---|---|---
)NPUT – “TUH (A)| 60,000 / 30,000| 80,000 / 40,000| 100,000 / 50,000| 120,000
/ 60,000
(EATING #APACITY – “TUH| 58,200 / 29,100| 77,600 / 38,800| 97,000 / 48,500|
116,400 / 58,200
AFUE| 97.0| 97.2| 97.4| 97.0
“LOWER $ X 7| 11 X 8| 11 X 10| 11 X 10| 11 X 10
-OTOR (.0. – 3PEED – 4YPE| 1/2 – 6ARIABLE| 3/4 – 6ARIABLE| 3/4 – 6ARIABLE| 1 – 6ARIABLE
-OTOR &,!| 6.2| 8.7| 8.7| 11.70
2ATED %XT. 30 – )N. 7.#.| 0.5| 0.5| 0.5| 0.5
4EMPERATURE 2ISE 2ANGE – Ž&| 30-60| 35-65| 35-65| 40-70
3HIPPING 7EIGHTS| 130LBS| 140LBS| 150LBS| 165LBS
NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
AIRFLOW DATA
Gas Input Rate (Btuh)
| Target CFM for Selected Circulating Air Temperature Rises, F
---|---
45| 50| 55| 60| ****
Constant
Full Input| Minimum Input| Full Input| Minimum
Input| Full Input| Minimum Input| Full Input|
Minimum Input
60,000| 1,110| 635| 1,000| 560| 940| 515| 850| 470| 950
80,000| 1,480| 850| 1,345| 740| 1,255| 685| 1,140| 625| 1,300
100,000| 1,850| 1,050| 1,680| 925| 1,565| 855| 1,460| 780| 1,760
120,000| 2,225| 1,270| 2,020| 1,115| 1,890| 1,025| 1,730| 940| 2,100
NOTE: This table lists the High and Low target CMs for each maximum input rate and temperature rise. If the target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
ACCESSORIES
FG7MQ KITS
Description| SKU
2″ #ONCENTRIC VENT KIT| 904177
3″ #ONCENTRIC VENT KIT| 904176
2″ 3IDE WALL VENT KIT| 904617
3″ 3IDE WALL VENT KIT| 904347
5.3. ,0 #ONVERSION KIT (0 TO 10,000 FT.) FOR 53 AND #ANADA| 904950
“OTTOM RETURN lLTER 20 PER BOX, “”” CABINET| 904916
“OTTOM RETURN lLTER 20 PER BOX, “#” CABINET| 904917
“OTTOM RETURN lLTER 20 PER BOX, “$” CABINET| 904918
3IDE RETURN lLTER KIT| 541036
.EUTRALIZER KIT| 902377
GENERAL TERMS OF LIMITED WARRANTY
- NORDYNE will furnish a replacement for any part of this product that fails in normal use and service within the first ten years of installation, per the terms of the warranty
- For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.
- 8000 Phoenix Parkway I O’Fallon MO 63368-3827
- Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in U.S.A (05/2009)
- 212D-0509 (Replaces 212D-0309)
- www.broanhvac.net.
- Broan® trademark used under license. © Nortek Global HVAC. LLC. All Rights Reserved
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>