BROAN G7SD Gas Furnace Owner’s Manual
- June 15, 2024
- Broan
Table of Contents
BROAN G7SD Gas Furnace
G7SD
High Efficiency, Single Stage
Condensing, Upflow/Horizontal
Gas Furnace Models
95.0 AFUE
38,000 – 120,000 Btuh Input
The high efficiency upflow gas furnace may be installed free standing in a
utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal
units come ready for upflow or horizontal application. The extended flush
jacket provides a pleasing “appliance appearance.” Design certified by CSA for
application in Canada and the United States.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- 30 second blower delay at start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
- High Static Blowers: All models equipped with high static blowers.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
- 60 second fixed cooling cycle blower-off delay (TDR) increases cooling performance when matched with a Nortek Global HVAC coil.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Dip switches on PCB provide easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Incorporates integrated control board with connections for electronic air cleaner and humidifier.
- Two piece door design enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
- Sealed Vestibule reduces burner and inducer sound levels.
- Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
- PolyPro by DuraVent: These furnaces have been tested with and are approved to be installed with DuraVent’s PolyPro venting system.
GAS FURNACE COMPONENTS
UPFLOW / HORIZONTAL FURNACE
SD Series -Upflow / Horizontal Furnace
DIMENSIONS
*SD Upflow / Horizontal Furnaces
Model #’s| Dim. -A-| Dim -B-| Dim -C-
038D-24B| ****
17 1/2
| ****
15 7/8
| ****
16 1/8
054D-24B
072D-35C| ****
21
| ****
19 3/8
| ****
19 5/8
090D-35C
108D-45D| 24 1/2| 22 7/8| 23 1/8
NOTE: Dimensions shown in inches.
*SD Series -Upflow / Horizontal Furnace
BLOWER PERFORMANCE
G7SD
*SD – UPFLOW / HORIZONTAL FURNACES|
---|---
Model Number &
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)|
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
| HIGH *****| 1519| 21| 1483| 22| 1433| 22| 1397| 23| 1335| 24| 1272| 25|
1214| 26| 1130| 27|
SD038D-24B
Bottom Return (38,000)
| MED-H **
MED-L
| 1238
1094
| 28| 1216
1082
| 28| 1188
1052
| 28| 1164
1034
| 29| 1136
1021
| 30
34
| 1092
977
| 31
34
| 1043
928
| 32
36
| 973
865
| 34
37
|
31| 32| 32| 33
| LOW| 841| 40| 817| 42| 801| 43| 786| 45| 750| 46| 720| 48| 683| 49| 639|
53|
| HIGH *****| 1664| 18| 1631| 21| 1596| 21| 1546| 22| 1489| 23| 1433| 24|
1366| 25| 1285| 26|
SD038D-24B
Side Return (38,000)
| MED-H
MED-L **
| 1272
1130
| 26
29
| 1255
1114
| 27| 1249
1100
| 27| 1217
1079
| 28| 1189
1048
| 29| 1145
1025
| 30
33
| 1096
987
| 31
35
| 1036
944
| 33
36
|
31| 31| 31| 33
| LOW| 869| 39| 839| 42| 809| 42| 790| 44| 764| 45| 739| 47| 711| 48| 664|
52|
| HIGH *| 1519| 33| 1483| 34| 1433| 35| 1397| 36| 1335| 37| 1272| 39|
1214| 41| 1130| 44|
SD054D-24B| MED-H| 1238| 40| 1216| 41| 1188| 42| 1164| 43| 1136| 44| 1092| 46|
1043| 48| 973| 51|
Bottom Return (54,000)| MED-L **| 1094| 46| 1082| 46| 1052| 48| 1034| 48|
1021| 49| 977| 51| 928| 54| 865| 58|
| LOW| 841| 59| 817| 61| 801| 62| 786| 64| 750| 67| 720| 69| 683| 73| 639|
78|
| HIGH *| 1664| 30| 1631| 31| 1596| 31| 1546| 32| 1489| 34| 1433| 35|
1366| 37| 1285| 39|
SD054D-24B
Side Return (54,000)
| MED-H
MED-L **
| 1272
1130
| 39
44
| 1255
1114
| 40
45
| 1249
1100
| 40
45
| 1217
1079
| 41
46
| 1189
1048
| 42
48
| 1145
1025
| 44
49
| 1096
987
| 46
51
| 1036
944
| 48
53
|
| LOW| 869| 58| 839| 60| 809| 62| 790| 63| 764| 65| 739| 68| 711| 70| 664|
75|
| HIGH *****| 1933| 34| 1857| 36| 1780| 37| 1695| 39| 1599| 42| 1498| 45|
1396| 48| 1280| 52|
SD072D-35C
Bottom Return (54,000)
| MED-H **
MED-L
| 1872
1320
| 36
51
| 1804
1299
| 37
51
| 1731
1264
| 39
53
| 1639
1233
| 41
54
| 1551
1183
| 43
56
| 1458
1126
| 46
59
| 1353
1059
| 49
63
| 1237
963
| 54|
69|
| LOW| 1185| 56| 1170| 57| 1132| 59| 1102| 60| 1067| 62| 1015| 66| 947| 70|
856| 78|
| HIGH *****| 1916| 35| 1848| 36| 1773| 38| 1692| 39| 1613| 41| 1515| 44|
1426| 47| 1316| 51|
SD072D-35C
Side Return (54,000)
| MED-H **
MED-L
| 1815
1259
| 37
53
| 1771
1241
| 38
54
| 1711
1224
| 39
54
| 1641
1192
| 41
56
| 1553
1163
| 43
57
| 1468
1115
| 45
60
| 1373
1056
| 49
63
| 1270
982
| 52|
68|
| LOW| 1139| 59| 1120| 60| 1096| 61| 1075| 62| 1047| 64| 1014| 66| 959| 70|
884| 75|
SCD72D-35C
Side + Bottom or 2 Sides
(72,000)
| HIGH * MED-H ** MED-L| 1954
1869
1287
| 34| 1890
1805
1262
| 35
37
53
| 1824
1741
1231
| 37
38
54
| 1741
1685
1197
| 38
40
56
| 1656
1607
1166
| 40
41
57
| 1564
1516
1117
| 43
44
60
| 1470
1419
1061
| 45
47
63
| 1352
1308
966
| 49
51
|
36
52
69|
66| 70
| LOW| 1147| 58| 1115| 60| 1097| 61| 1075| 62| 1047| 64| 1014| 959| 884| 75|
| HIGH *****| 2288| 36| 2236| 37| 2161| 39| 2092| 40| 2017| 41| 1934| 43|
1841| 45| 1748| 48|
SD090D-35C
Bottom Return (90,000)
| MED-H **
MED-L
| 2144
1874
| 39
44
| 2093
1845
| 40
45
| 2049
1806
| 41
46
| 1985
1766
| 42
47
| 1912
1717
| 44
49
| 1842
1661
| 45
50
| 1764
1582
| 47
53
| 1668
1503
| 50
55
|
| LOW| 1541| 54| 1516| 55| 1509| 55| 1486| 56| 1456| 57| 1402| 59| 1361| 61|
1294| 64|
| HIGH *****| 2273| 37| 2222| 38| 2164| 39| 2098| 40| 2025| 41| 1947| 43|
1864| 45| 1780| 47|
SD090D-35C
Side Return (90,000)
| MED-H **
MED-L
| 2084
1784
| 40
47
| 2039
1777
| 41
47
| 2007
1749
| 42
48
| 1955
1725
| 43
48
| 1895
1679
| 44
50
| 1832
1629
| 45
51
| 1750
1576
| 48
53
| 1665
1501
| 50
56
|
| LOW| 1482| 56| 1470| 57| 1444| 58| 1432| 58| 1405| 59| 1375| 61| 1339| 62|
1286| 65|
SCD90D-35C
Side + Bottom or 2 Sides
(90,000)
| HIGH * MED-H ** MED-L| 2328
2124
1825
| 36
39
46
| 2273
2108
1809
| 37
40
46
| 2224
2052
1781
| 37
41
47
| 2151
2018
1752
| 39
41
48
| 2082
1954
1706
| 40
43
49
| 2005
1884
1676
| 42
44
50
| 1920
1813
1615
| 43
46
52
| 1825
1725
1535
| 46
48
54
|
| LOW| 1509| 55| 1488| 56| 1468| 57| 1440| 58| 1422| 59| 1379| 60| 1351| 62|
1292| 64|
Model Number &
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)
---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise
| HIGH *****| 2276| 44| 2228| 45| 2173| 46| 2108| 47| 2035| 49| 1961| 51|
1876| 53| 1778| 56
SD108D-45D
Bottom Return (108,000)
| MED-H **
MED-L
| 2113
1819
| 47
55
| 2078
1789
| 48
56
| 2019
1757
| 50
57
| 1970
1706
| 51
59
| 1904
1666
| 53
60
| 1840
1610
| 54
62
| 1768
1551
| 57
64
| 1677
1486
| 60
67
| LOW| 1496| 67| 1484| 67| 1459| 69| 1430| 70| 1402| 71| 1363| 73| 1330| 75|
1262| 79
| HIGH *****| 2306| 43| 2247| 45| 2192| 46| 2121| 47| 2044| 49| 1979| 51|
1892| 53| 1787| 56
SD108D-45D
Side Return (108,000)
| MED-H ** MED-L| 2135
1845
| 47
54
| 2103
1834
| 50
57
| 2050
1805
| 51
58
| 1995
1776
| 53
59
| 1935
1719
| 54
61
| 1858
1663
| 57
63
| 1778
1605
| 59
66
| 1690
1533
| 62
69
| LOW| 1543| 65| 1521| 69| 1502| 70| 1477| 71| 1452| 73| 1412| 75| 1368| 77| 1314| 80
VENTING
All models are approved for vertical non direct (1 pipe) and direct (2 pipe)
venting applications. See Vent Table below for specified sizes and allowable
lengths.
VENT TABLE
| SINGLE PIPE LENGTH (FT.)
with 1 long radius elbow*
| DIRECT VENT,
DUEL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe*
---|---|---
OUTLET| OUTLET| INLET/OUTLET| INLET/OUTLET
MODELS| 2”| 3”| 2”| 3”
SD038| 50| 70| 50| 70
SD054| 70| 90| 70| 90
SD072| 50| 90| 50| 90
SD090| 60| 90| 60| 90
SD108| N/A| 90| N/A| 90
NOTE:
- Subtract 2.5 ft. for each additional 2″ elbow and 3.5 ft. for each additional 3″ elbow.
- Two 45 degree elbows are equivalent to one 90 degree elbow.
- One short radius elbow is equivalent to two long radius elbows.
- Do not include termination elbows in calculation of vent length.
- This table is applicable for elevations from sea level to 2000 ft. For higher elevations decrease vent pipe lengths by 8% per 1000 ft. of altitude.
- Only the listed pipe materials are approved for use with FG7 Condensing Furnaces.
MODEL IDENTIFICATION CODE
SPECIFICATIONS
G7SD MODEL NUMBERS:| -038D-T24B1| -054D-T24B1| -072D-
T35C1| -090D-T35C1| -108D-T45D1
---|---|---|---|---|---
Input – Btuh (a)| 38,000| 54,000| 72,000| 85,000| 108,000
Heating Capacity – Btuh| 36,000| 51,000| 68,000| 81,000| 103,000
AFUE (b)| 95.0 / 94.0| 95.0 / 90.0| 95.0 / 90.0| 95.0 / 94.0| 95.0 / 90.0
Blower D x W| 10 x 8| 11 x 8| 10 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 1 – 5
– ECM| 1 – 5 – ECM
Motor FLA| 8.8| 8.8| 8.8| 11.5| 11.5
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 25-55| 30-60| 35-65| 35-65| 35-65
Shipping Weights| 100lbs| 120lbs| 130lbs| 135lbs| 155lbs
Note:
All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency
- Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
- AFUE for Upflow/Horizontal application.
ACCESSORIES
G7SD KITS
Description| SKU
2″ Concentric vent kit, Canadian and US approved| 904952
3″ Concentric vent kit, Canadian and US approved| 904953
2″ Side wall vent kit| 904617
3″ Side wall vent kit| 904347
U.S. LP Conversion kit (0 to 10,000 ft.)| 905028
Canada LP Conversion kit (0 to 4,500 ft.)| 905029
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036
Neutralizer kit| 902377
Furnace Twinning Kit| 1010035
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this
product which fails in normal use and service within the terms and conditions
of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (04/2022)
593F-0422 (Replaces 593F-1021)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>