Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner Owner’s Manual

June 15, 2024
Gibson

Gibson LOGO TECHNICAL SPECIFICATIONS
P8SE Series
14 SEER, Single Phase
Packaged Air Conditioner
3, 4, 5 Ton Units

P8SE Series 14 Seer Single Phase Packaged Air Conditioner

The P8 Series single packaged air conditioners are high efficiency self contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed.

Gibson P8SE Series 14 Seer Single Phase Packaged Air
Conditioner

FEATURES and BENEFITS

  • State-of-the-Art Compressor: Copeland scroll is a standard component.
  • Micro-Channel Coils: Both indoor and outdoor coils are robustly designed for harsh conditions while reducing unit weight and refrigerant charge.
  • 5-Speed ECM Blower Motor: Provides greater airflow flexibility even in challenging duct applications.
  • Proven, Industry Standard Components: Easier service and availability.
  • TXV Externally Equalized: Provides precise refrigerant control under varying load conditions.
  • High and Low Pressure Switches: Added compressor protection.
  • Liquid Line Filter Drier: Insures clean and dry refrigeration system.
  • Externally Accessible Service Ports: Quick access to refrigerant system without disrupting operation.
  • Compact Footprint/Low Profile: Easy to handle and transport.
  • Convertible Air Delivery: Horizontal or downflow to accommodate slab or rooftop application.
  • Heavy-Gauge, Full Perimeter Base Rails: Facilitates forklift handling, crane hoisting and curb mounting.
  • Galvanized Steel Cabinet: Polyurethane finish provides 950 hours salt spray protection.
  • Wire Guard Coated with Earth Friendly Epoxy and Mesh Hail Guard: Will never rust and protects the coil from being damaged by balls, lawnmowers, hail etc.
  • Drain Pan: Quickly drains away evaporator condensate.
  • Quiet Operation and Low Vibration: Fan blade combined with custom venturi condenser fan.
  • Access to Controls and Major Components: Easy in and out service.
  • Service Access Panels: Allows easy access to all major components and the compressor. Designed to make servicing easier for the Contractor.
  • Corner Protectors: Prevent injury from sharp edges of unit’s top pan.
  • Easy to Install: Electric heat strips provide up to 20 KW of heat output.
  • Accessories: Roof curbs, title 24 compliant economizers, fresh air dampers and more.

MODEL IDENTIFICATION CODE

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner -
IDENTIFICATION CODE

DIMENSIONS (inches and pounds)

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner -
DIMENSIONSDIMENSIONS

Model Number P8SE-| Net Weight| Ship Weight| Center of Gravity| Height (in inches) C
---|---|---|---|---
A| B| with base rails| without base rails
X36K| 354| 375| 29.0| 20.5| 35.0| 30.76
X48K| 377| 398| 29.0| 20.5| 35.0| 30.76
X60K| 416| 437| 27.75| 23.5| 43.0| 39.0

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner -
DIMENSIONS

SPECIFICATIONS

Model Number P8SE
X36K X48K

Performance
Capacity -Cooling BTUH Efficiency – SEER
EER (Btuh/watt)| 35,000
14
11.2| 46,500
14
11.5| 57,000
14
11.0
Electrical Rating – 60 Hz
Phase
Operating Voltage Range| 1
187 – 253| 1
187 – 253| 1
187 – 253
Compressor Data
Volts
Rated Load Amps Lock Rotor Amps| 208 / 230
18.6
79| 208 / 230
24.3
117| 208 / 230
29.3
134
Indoor Blower
Motor – Amps| 3.8| 5.4| 5.4
Outdoor Fan
Motor – Amps| 1.46| 1.46| 1.46
Refrigerant Charge – Oz.| 58| 61| 67

BLOWER PERFORMANCE

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner - BLOWER
PERFORMANCE

  • Denotes factory set cooling speed
    ** Denotes factory set electric heating speed
    Calculations made based on 10KW/H, airflow performace with dry coil
    Shaded ares represent speeds not recommended for heating mode w/10kw heater or higher

HEATER KIT MODEL IDENTIFICATION CODE

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner -
IDENTIFICATION CODE 2

HEATER KIT APPLICATION MATRIX

TONNAGE & PHASE| UNIT| NOMINAL KW| HEATER KIT MODEL| HEATER KIT PART NUMBER| BREAKERS REQUIRED
---|---|---|---|---|---
3 Ton, Single Phase| P8SE| 5| H3HK005H-01C| 917166C| None
8| H3HK008H-01C| 917167C| None
10| H3HK010H-01C| 917168C| None
15| H3HK015H-01C| 917169C| 2
15| H3HK015H-21C| 917172C| None
4 Ton, Single Phase| P8SE| 5| H3HK005H-01C| 917166C| None
8| H3HK008H-01C| 917167C| None
10| H3HK010H-01C| 917168C| None
15| H3HK015H-01C| 917169C| 2
15| H3HK015H-21C| 917172C| None
20| H3HK020H-01C| 917170C| 2
20| H3HK020H-21C| 917173C| None
5 Ton, Single Phase| P8SE| 5| H3HK005H-01C| 917166C| None
8| H3HK008H-01C| 917167C| None
10| H3HK010H-01C| 917168C| 2
15| H3HK015H-01C| 917169C| 2
15| H3HK015H-21C| 917172C| None
20| H3HK020H-01C| 917170C| 3
20| H3HK020H-21C| 917173C| 1

ELECTRICAL DATA

P8SE SERIES – 208/230V – SINGLE PHASE MODELS

MODEL NUMBER P8SE| HEATER INSTALLED NOMINAL KW| SINGLE CIRCUIT| MULTIPLE SUPPLY CIRCUIT OPTION
MCA| MOP| CIRCUIT A (C OMPRESSOR , B LOWER , & F AN )| CIRCUIT B (H EATER O NLY )| CIRCUIT C (H EATER O NLY )
MCA| MOP| MCA| MOP| MCA| MOP
P8SE-X36K| 0| 28.5| 45| –| –| –| –| –| –
5| 29.8| 45| –| –| –| –| –| –
8| 44.3| 45| 28.5| 45| 39.6| 40| –| –
10| 54.8| 60| 28.5| 45| 50| 60| –| –
15| 79.8| 80| 28.5| 45| 79.8| 80| –| –
P8SE-X48K| 0| 34.1| 50| –| –| –| –| –| –
5| 34.1| 50| –| –| –| –| |
8| 46.3| 50| 34.1| 50| 39.6| 40| |
10| 56.8| 60| 34.1| 50| 50| 60| |
15| 81.8| 90| 34.1| 50| 75| 80| |
15(3 CIR)| | | 34.1| 50| 25| 30| 50| 60
20| 106.8| 110| 56.8| 60| 50| 60| |
20(3 CIR)| | | 34.1| 50| 50| 60| 50| 60
P8SE-X60K| 0| 43.5| 70| –| –| –| –| –| –
5| 43.5| 70| –| –| –| –| –| –
8| 46.3| 70| 43.5| 70| 39.6| 40| –| –
10| 56.8| 70| 43.5| 70| 50| 60| –| –
15| 81.8| 90| 43.5| 70| 75| 80| –| –
15(3 CIR)| | | 43.5| 70| 25| 30| 50| 60
20| 106.8| 110| 43.5| 70| 100| 110| |
20(3 CIR)| | | 43.5| 70| 50| 60| 50| 60

ACCESSORIES

**** Part Number
Roof Curb (8”) 547830
Roof Curb (14”) 547831
Roof Curb (18”) 547850
Roof Curb (24”) 547851
Supply/Return Transition, 16” 547834
Supply/Return Transition, 18” 547835
Concentric Diffuser, flush, 18” 547837
Concentric Diffuser, step down 16” 547838
Concentric Diffuser, step down 18” 547839
Manual Fresh Air Damper 547832
Motorized Fresh Air Damper 547840
Economizer, Downflow, Modulating w/filter (does not require filter kit)

558870
Economizer, Downflow, Modulating w/filter (does not require filter kit) CA, title 24, 3 – 4 Ton| 562533
Economizer, Downflow, Modulating w/filter (does not require filter kit) CA, title 24, 5 Ton| 563209
Economizer, Horizontal, Modulating, CA, title 24| 562534
Power Exhaust Horizontal Economizer (special order)| 547843
Hood Type Hail Guard 34” X 76” P8SE-X36K, P8SE-X48K| 547846
Hood Type Hail Guard 38” X 76” P8SE-X60K| 547847
Duct Smoke Detector Photo Elec| 558863
Multi Signal Control| 558866
Sampling Tube DST5, 2-4′| 558864
Sampling Tube DST5, 4-8′| 558865
Filter Rack Kit (not required with downflow economizer) P8SE-X36K, P8SE-X48K| 10079911R
Filter Rack Kit (not required with downflow economizer) P8SE-X60K| 10079915R
Universal Hard Start Kit| 912933
Low Ambient Kit| 918837
Skirt Trim Kit| 919729
Heater Kit – 4-Pole single circuit adaptor| 913350
Heater Kit – 6-Pole single circuit adaptor| 913556
Heater Kit – Circuit breaker single phase (2-pole)| 913554
Outdoor Tstat Kit| 913852
Duct Adaptor, 12″ Round (2 each)| 913811A
Duct Adaptor, 14″ Round (2 each)| 913812A
CO2 Sensor Kit, Wall Mount| 920317
CO2 Sensor Kit, Duct Mount| 920318
Differential Enthalpy Kit| 922431

COOLING EXPANDED RATINGS

Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner - EXPANDED
RATINGSGibson P8SE
Series 14 Seer Single Phase Packaged Air Conditioner -
Symbol

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (09/2017)
GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.

311E-0917 (Replaces 311E-0316)
www.gibsonhvac.com

Documents / Resources

| Gibson P8SE Series 14 Seer Single Phase Packaged Air Conditioner [pdf] Owner's Manual
P8SE Series 14 Seer Single Phase Packaged Air Conditioner, P8SE Series, 14 Seer Single Phase Packaged Air Conditioner, Single Phase Packaged Air Conditioner, Packaged Air Conditioner, Air Conditioner
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Gibson User Manuals

Related Manuals