Gibson G7S (A and K Series) Single Stage Upflow/Horizontal and Downflow Gas Furnaces Owner’s Manual

June 15, 2024
Gibson

TECHNICAL SPECIFICATIONS
G7S (A and K Series)

G7S (A and K Series) Single Stage Upflow/Horizontal and Downflow Gas

Furnaces

Single Stage Upflow/Horizontal and Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.Gibson G7S \(A and K Series\) Single Stage
Upflow Horizontal and Downflow Gas FurnacesThis furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge: Increases life of heat exchanger.
  • Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models equipped with high static blowers.
  • 60 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
  • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
  • Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. Dip switches on PCB provide easy motor speed selection.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service.
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartment: Insulated for ultra quiet operation.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

Gibson G7S \(A and K Series\) Single Stage Upflow Horizontal and Downflow
Gas Furnaces - Figure 1

1. Blower Assembly
2. Blower Door Switch
3. Burner Assembly
4. Control Board
5. Flame Sensor
6. Gas Manifold
7. Gas Valve| 8. Igniter
9. Inducer
10. Insulated Combustion Tube (Downflow Models)
11. Low Voltage Transformer
12. Main Air Limit Switch
13. Pressure Switch
14. Roll-Out Switch(s)
---|---

DIMENSIONS

*SA Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| 21| 14| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

Gibson G7S \(A and K Series\) Single Stage Upflow Horizontal and Downflow
Gas Furnaces - Figure 2

*SK Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
054-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
108-35C| 21| 14| 19 3/8| 19 5/8
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

Gibson G7S \(A and K Series\) Single Stage Upflow Horizontal and Downflow
Gas Furnaces - Figure 3

MODEL IDENTIFICATION CODE

Gibson G7S \(A and K Series\) Single Stage Upflow Horizontal and Downflow
Gas Furnaces - Figure 4

SPECIFICATIONS

G7SA MODEL NUMBERS| -045-T23A1| -054-T23A1| -072-T24B1| -072-T35C1| -090-T24B1| -090-T35C1| -108-T35C1| -126-T45D1
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 52,000| 70,000| 75,000| 90,000| 85000| 108000| 122000
Heating Capacity – Btuh| 36,000| 42,000| 56,000| 60,000| 72,000| 68000| 86000| 98000
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80| 80| 80
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 3/4-5-ECM| 1-5-ECM| 1-5-ECM
Motor FLA| 6.4| 6.4| 8.8| 8.8| 8.8| 8.8| 11.5| 11.5
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70
Shipping Weights| 95 lbs| 95 lbs| 110 lbs| 115 lbs| 115 lbs| 134 lbs| 136 lbs| 147 lbs
G7SK MODEL NUMBERS| -054C-T23A1| -072-T24B1| -090-T24B1
---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000
Heating Capacity – Btuh| 43,000| 58,000| 72,000
AFUE| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM
Motor FLA| 6.4| 8.8| 8.8
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65
Shipping Weights| 102 lbs| 110 lb| 115 lb

ACCESSORIES

G7S(A,K) KITS

Description| SKU
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.) and High Altitude LP| 905028
Canada LP Conversion kit (0 to 4,500 ft.) and High Altitude LP| 905029
Side return filter kit| 541036
Furnace Twinning Kit| 1010035

Gibson G7S \(A and K Series\) Single Stage Upflow Horizontal and Downflow
Gas Furnaces - Logo 1 GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
Specifications and illustrations subject to change without notice and without incurring obligations.
Printed in U.S.A (04/2022)
575F-0422 (Replaces 575F-0220)
GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.

www.gibsonhvac.com

Documents / Resources

| Gibson G7S (A and K Series) Single Stage Upflow/Horizontal and Downflow Gas Furnaces [pdf] Owner's Manual
G7S A K, KG7S A K, G7S A and K Series Single Stage Upflow Horizontal and Downflow Gas Furnaces, G7S A and K Series, Single Stage Upflow Horizontal and Downflow Gas Furnaces, Upflow Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Gibson User Manuals

Related Manuals