BROAN KG7TC Series Condensing Upflow/Horizontal Gas Furnaces Owner’s Manual

June 15, 2024
Broan

TECHNICAL SPECIFICATIONS
KG7TC Series Smartlite ® Two Stage, Fixed Speed ECM,

Condensing Upflow/Horizontal Gas Furnaces
Induced Draft – 95.1 AFUE
Input 60,000 – 120,000 Btuh

KG7TC Series Condensing Upflow/Horizontal Gas Furnaces

The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/Horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing  appliance appearance.” Design certified by CSA for application in Canada and the United States.

This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.

FEATURES and BENEFITS

  • Multi-speed direct drive blower: Energy-efficient brushless DC (ECM) motor provides 16 speeds designed to give a wide range of cooling capacities.

  • 100% fired and tested: All units and each component are tested on the manufacturing line.

  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.

  • 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).

  • 30 second post purge: Increases life of heat exchanger.

  • Hot surface igniter: Innovative application of an appliance type igniter with a 20 year history of reliability. Utilizes proven Smartlite® technology.

  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.

  • Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.

  • High Static Blowers: All models equipped with high static blowers.

  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.

  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.

  • 60 second fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil.

  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.

  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.

  • Incorporates integrated control board: With connections for electronic air cleaner and humidifier.
    Ergonomically located for ease of service.

  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.

  • Sealed vestibule: Reduces burner and inducer sound levels.

  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

  • PolyPro by DuraVent: These furnaces have been tested with and are approved to be installed with DuraVent’s PolyPro venting system.

LOCATION OF FURNACE COMPONENTS

DIMENSIONS

*TC 95.1% Upflow/Horizontal Furnace

Cabinet Size Dim. “A” Dim. gir Dim. iv,
EY Cabinet 17 1/2 15 7/8
C’ Cabinet 21 19 3/8
D’ Cabinet 24 1/2 22 7/8
NOTES:
Dimensions shown in inches.

MODEL IDENTIFICATION CODE

SPECIFICATIONS

KG7TC MODEL NUMBERS: -060D-E24B1 -080D-E35C1 -100D-E35C1 -120D-E45D1
Input – Btuh (a) 60000 / 39000 80000 / 52000 100000 / 65000 120000 / 78000
Heating Capacity – BtuH 57000 / 37000 76000 / 49000 95000 / 62000 113000 /

74000
AFUE| 95.0| 95.0| 95.0| 94.
Motor H.P – Speed – Type| 3/4 – BLDC| 1 – BLDC| 1 – BLDC| 1 – BLDC
Motor FLA| 9.| 12.| 12.| 12.
Rated Ext. SP – In. W.C.| 0.50| 0.50| 0.50| 0.50
Temperature Rise Range – F| 30-60| 35-65| 35-65| 40-70
Shipping Weights| 120 lb| 130 lb| 140 lb| 155 lb
SKU| 1025920K| 1025921K| 1025922K| 1025923K

Note:
All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

KG7TC-060D-E24B (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE
KG7TC-060D-E24B 60,000 BTU/hr| 0| 0| 0| 0| | | | | | | | | |
1| 0| 0| 0| | | | | | | | | |
0| 1| 0| 0| | | | | | | | | |
1| 1| 0| 0| | | | | | | | | |
0| 0| 1| 0| | | | | | | | | |
1| 0| 1| 0| 940| 56| 890| 59| | | | | |
0| 1| 1| 0| 990| 53| 945| 56| 905| 58| | | |
1| 1| 1| 0| 1,055| 50| 1,015| 52| 970| 54| 930| 57| 890| 59
0| 0| 0| 1| 1,135| 47| 1,095| 48| 1,055| 50| 1,010| 52| 960| 55
1| 0| 0| 1| 1,185| 45| 1,145| 46| 1,105| 48| 1,065| 50| 1,030| 51
0| 1| 0| 1| 1,250| 42| 1,210| 44| 1,170| 45| 1,135| 47| 1,095| 48
1| 1| 0| 1| 1,290| 41| 1,255| 42| 1,220| 43| 1,180| 45| 1,145| 46
0| 0| 1| 1| 1,315| 40| 1,275| 41| 1,240| 43| 1,200| 44| 1,160| 45
1| 0| 1| 1| 1,350| 39| 1,315| 40| 1,280| 41| 1,245| 42| 1,205| 44
0| 1| 1| 1| 1,390| 38| 1,350| 39| 1,315| 40| 1,275| 41| 1,240| 43
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)
KG7TC-060D-E24B 60,000 BTU/hr| 0| 0| 0| 0| | | | | | | |
1| 0| 0| 0| | | | | | | |
0| 1| 0| 0| | | | | | | |
1| 1| 0| 0| 725| | | | | | |
0| 0| 1| 0| 810| | | | | | |
1| 0| 1| 0| 940| 890| 845| 795| 750| 700| |
0| 1| 1| 0| 990| 945| 905| 860| 820| 775| 735| 690
1| 1| 1| 0| 1,055| 1,015| 970| 930| 890| 845| 805| 760
0| 0| 0| 1| 1,135| 1,095| 1,055| 1,010| 960| 930| 890| 850
1| 0| 0| 1| 1,185| 1,145| 1,105| 1,065| 1,030| 990| 950| 910
0| 1| 0| 1| 1,250| 1,210| 1,170| 1,135| 1,095| 1,055| 1,020| 980
1| 1| 0| 1| 1,290| 1,255| 1,220| 1,180| 1,145| 1,110| 1,075| 1,040
0| 0| 1| 1| 1,315| 1,275| 1,240| 1,200| 1,160| 1,120| 1,085| 1,045
1| 0| 1| 1| 1,350| 1,315| 1,280| 1,245| 1,205| 1,170| 1,135| 1,100
0| 1| 1| 1| 1,390| 1,350| 1,315| 1,275| 1,240| 1,200| 1,160| 1,125
1| 1| 1| 1| 1,420| 1,380| 1,345| 1,310| 1,270| 1,235| 1,200| 1,160

*NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

KG7TC-080D-E35C (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE
KG7TC-080D-E35C 80,000 BTU/hr| 0| 0| 0| 0| 1,125| 55| | | | | | | |
1| 0| 0| 0| 1,205| 58| 1,120| 63| | | | | |
0| 1| 0| 0| 1,305| 54| 1,225| 57| 1,150| 61| | | |
1| 1| 0| 0| 1,430| 49| 1,350| 52| 1,270| 55| 1,190| 59| 1,110| 63
0| 0| 1| 0| 1,525| 46| 1,450| 49| 1,375| 51| 1,300| 54| 1,225| 57
1| 0| 1| 0| 1,620| 43| 1,540| 46| 1,465| 48| 1,390| 51| 1,315| 54
0| 1| 1| 0| 1,695| 42| 1,620| 43| 1,545| 46| 1,465| 48| 1,390| 51
1| 1| 1| 0| 1,770| 40| 1,700| 41| 1,630| 43| 1,555| 45| 1,485| 47
0| 0| 0| 1| 1,875| 38| 1,805| 39| 1,730| 41| 1,655| 43| 1,580| 45
1| 0| 0| 1| 1,905| 37| 1,840| 38| 1,775| 40| 1,710| 41| 1,640| 43
0| 1| 0| 1| 1,980| 36| 1,910| 37| 1,845| 38| 1,780| 40| 1,715| 41
1| 1| 0| 1| 2,025| 35| 1,960| 36| 1,895| 37| 1,830| 38| 1,765| 40
0| 0| 1| 1| | | 2,025| 35| 1,960| 36| 1,900| 37| 1,840| 38
1| 0| 1| 1| | | | | 2,010| 35| 1,945| 36| 1,880| 37
0| 1| 1| 1| | | | | | | 2,035| 35| 1,980| 36
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)
KG7TC-080D-E35C 80,000 BTU/hr| 0| 0| 0| 0| 1,125| 1,040| 960| 880| 795| | |
1| 0| 0| 0| 1,205| 1,120| 1,040| 960| 875| 795| |
0| 1| 0| 0| 1,305| 1,225| 1,150| 1,070| 995| 915| 840|
1| 1| 0| 0| 1,430| 1,350| 1,270| 1,190| 1,110| 1,030| 950| 865
0| 0| 1| 0| 1,525| 1,450| 1,375| 1,300| 1,225| 1,150| 1,075| 1,000
1| 0| 1| 0| 1,620| 1,540| 1,465| 1,390| 1,315| 1,240| 1,165| 1,090
0| 1| 1| 0| 1,695| 1,620| 1,545| 1,465| 1,390| 1,315| 1,235| 1,160
1| 1| 1| 0| 1,770| 1,700| 1,630| 1,555| 1,485| 1,410| 1,340| 1,265
0| 0| 0| 1| 1,875| 1,805| 1,730| 1,655| 1,580| 1,510| 1,435| 1,340
1| 0| 0| 1| 1,905| 1,840| 1,775| 1,710| 1,640| 1,575| 1,510| 1,445
0| 1| 0| 1| 1,980| 1,910| 1,845| 1,780| 1,715| 1,650| 1,580| 1,515
1| 1| 0| 1| 2,025| 1,960| 1,895| 1,830| 1,765| 1,700| 1,635| 1,570
0| 0| 1| 1| 2,085| 2,025| 1,960| 1,900| 1,840| 1,775| 1,715| 1,655
1| 0| 1| 1| 2,135| 2,070| 2,010| 1,945| 1,880| 1,815| 1,750| 1,685
0| 1| 1| 1| 2,200| 2,145| 2,090| 2,035| 1,980| 1,925| 1,870| 1,820
1| 1| 1| 1| 2,280| 2,225| 2,170| 2,115| 2,065| 2,010| 1,955| 1,900

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

KG7TC-100D-E35C (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE
KG7TC-100D-E35C 100,000 BTU/hr| 0| 0| 0| 0| | | | | | | | | |
1| 0| 0| 0| | | | | | | | | |
0| 1| 0| 0| | | | | | | | | |
1| 1| 0| 0| 1,430| 62| 1,350| 65| | | | | |
0| 0| 1| 0| 1,525| 58| 1,450| 61| 1,375| 64| | | |
1| 0| 1| 0| 1,620| 54| 1,540| 57| 1,465| 60| 1,390| 63| |
0| 1| 1| 0| 1,695| 52| 1,620| 54| 1,545| 57| 1,465| 60| 1,390| 63
1| 1| 1| 0| 1,770| 50| 1,700| 52| 1,630| 54| 1,555| 57| 1,485| 59
0| 0| 0| 1| 1,875| 47| 1,805| 49| 1,730| 51| 1,655| 53| 1,580| 56
1| 0| 0| 1| 1,905| 46| 1,840| 48| 1,775| 50| 1,710| 51| 1,640| 54
0| 1| 0| 1| 1,980| 44| 1,910| 46| 1,845| 48| 1,780| 49| 1,715| 51
1| 1| 0| 1| 2,025| 43| 1,960| 45| 1,895| 46| 1,830| 48| 1,765| 50
0| 0| 1| 1| 2,085| 42| 2,025| 43| 1,960| 45| 1,900| 46| 1,840| 48
1| 0| 1| 1| 2,135| 41| 2,070| 42| 2,010| 44| 1,945| 45| 1,880| 47
0| 1| 1| 1| 2,200| 40| 2,145| 41| 2,090| 42| 2,035| 43| 1,980| 44
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)

MODEL NAME/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)
KG7TC-100D-E35C 100,000 BTU/hr| 0| 0| 0| 0| 1,125| 1,040| | | | | |
1| 0| 0| 0| 1,205| 1,120| 1,040| | | | |
0| 1| 0| 0| 1,305| 1,225| 1,150| 1,070| 995| | |
1| 1| 0| 0| 1,430| 1,350| 1,270| 1,190| 1,110| 1,030| |
0| 0| 1| 0| 1,525| 1,450| 1,375| 1,300| 1,225| 1,150| 1,075| 1,000
1| 0| 1| 0| 1,620| 1,540| 1,465| 1,390| 1,315| 1,240| 1,165| 1,090
0| 1| 1| 0| 1,695| 1,620| 1,545| 1,465| 1,390| 1,315| 1,235| 1,160
1| 1| 1| 0| 1,770| 1,700| 1,630| 1,555| 1,485| 1,410| 1,340| 1,265
0| 0| 0| 1| 1,875| 1,805| 1,730| 1,655| 1,580| 1,510| 1,435| 1,340
1| 0| 0| 1| 1,905| 1,840| 1,775| 1,710| 1,640| 1,575| 1,510| 1,445
0| 1| 0| 1| 1,980| 1,910| 1,845| 1,780| 1,715| 1,650| 1,580| 1,515
1| 1| 0| 1| 2,025| 1,960| 1,895| 1,830| 1,765| 1,700| 1,635| 1,570
0| 0| 1| 1| 2,085| 2,025| 1,960| 1,900| 1,840| 1,775| 1,715| 1,655
1| 0| 1| 1| 2,135| 2,070| 2,010| 1,945| 1,880| 1,815| 1,750| 1,685
0| 1| 1| 1| 2,200| 2,145| 2,090| 2,035| 1,980| 1,925| 1,870| 1,820
1| 1| 1| 1| 2,280| 2,225| 2,170| 2,115| 2,065| 2,010| 1,955| 1,900

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

KG7TC-120D-E45D (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NUMBER/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE| CFM| RISE
KG7TC-120D-E45D 120,000 BTU/hr| 0| 0| 0| 0| | | | | | | | | |
1| 0| 0| 0| | | | | | | | | |
0| 1| 0| 0| 1,555| 68| 1,510| 70| | | | | |
1| 1| 0| 0| 1,625| 65| 1,585| 67| 1,540| 69| 1,500| 70| |
0| 0| 1| 0| 1,690| 62| 1,650| 64| 1,610| 66| 1,570| 67| 1,530| 69
1| 0| 1| 0| 1,760| 60| 1,715| 62| 1,670| 63| 1,625| 65| 1,575| 67
0| 1| 1| 0| 1,835| 58| 1,790| 59| 1,745| 60| 1,695| 62| 1,650| 64
1| 1| 1| 0| 1,885| 56| 1,840| 57| 1,790| 59| 1,745| 60| 1,700| 62
0| 0| 0| 1| 1,945| 54| 1,900| 56| 1,850| 57| 1,805| 58| 1,760| 60
1| 0| 0| 1| 1,950| 54| 1,905| 55| 1,860| 57| 1,820| 58| 1,775| 59
0| 1| 0| 1| 2,075| 51| 2,030| 52| 1,990| 53| 1,945| 54| 1,900| 56
1| 1| 0| 1| 2,125| 50| 2,085| 51| 2,040| 52| 2,000| 53| 1,955| 54
0| 0| 1| 1| 2,170| 49| 2,130| 50| 2,090| 51| 2,045| 52| 2,005| 53
1| 0| 1| 1| 2,215| 48| 2,180| 48| 2,140| 49| 2,105| 50| 2,070| 51
0| 1| 1| 1| | | | | | | | | 2,225| 47
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)

MODEL NAME/ HEATING INPUT| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)| EXTERNAL STATIC PRESSURE (in. w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)| (CFM)
KG7TC-120D-E45D 120,000 BTU/hr| 0| 0| 0| 0| 1,395| 1,350| 1,305| 1,260| 1,210| 1,165| 1,120|
1| 0| 0| 0| 1,465| 1,420| 1,375| 1,330| 1,290| 1,245| 1,200| 1,155
0| 1| 0| 0| 1,555| 1,510| 1,470| 1,425| 1,380| 1,340| 1,295| 1,250
1| 1| 0| 0| 1,625| 1,585| 1,540| 1,500| 1,460| 1,415| 1,375| 1,335
0| 0| 1| 0| 1,690| 1,650| 1,610| 1,570| 1,530| 1,485| 1,445| 1,405
1| 0| 1| 0| 1,760| 1,715| 1,670| 1,625| 1,575| 1,530| 1,485| 1,440
0| 1| 1| 0| 1,835| 1,790| 1,745| 1,695| 1,650| 1,605| 1,555| 1,510
1| 1| 1| 0| 1,885| 1,840| 1,790| 1,745| 1,700| 1,655| 1,610| 1,565
0| 0| 0| 1| 1,945| 1,900| 1,850| 1,805| 1,760| 1,710| 1,665| 1,620
1| 0| 0| 1| 1,950| 1,905| 1,860| 1,820| 1,775| 1,735| 1,690| 1,650
0| 1| 0| 1| 2,075| 2,030| 1,990| 1,945| 1,900| 1,855| 1,810| 1,770
1| 1| 0| 1| 2,125| 2,085| 2,040| 2,000| 1,955| 1,910| 1,870| 1,825
0| 0| 1| 1| 2,170| 2,130| 2,090| 2,045| 2,005| 1,965| 1,925| 1,880
1| 0| 1| 1| 2,215| 2,180| 2,140| 2,105| 2,070| 2,035| 2,000| 1,965
0| 1| 1| 1| | | | | 2,225| 2,165| 21,000| 2,040
1| 1| 1| 1| | | | | | 2,170| 2,120| 2,065

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

VENTING

All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.

VENT TABLE

FURNACE MODELS (BTU)| FURNACE INSTALLATION| SINGLE PIPE LENGTH (FT.) with 1 long radius elbow**| DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe**
---|---|---|---
OUTLET| OUTLET| INLET/OUTLET| INLET/OUTLET
2” Diameter| 3” Diameter| 2” Diameter| 3” Diameter
60,000| Upflow| 90| 90| 90| 90
Horizontal| 50| 90| 50| 90
80,000| Upflow| 40| 90| 40| 90
Horizontal| 30| 90| 30| 90
100,000| Upflow| 30| 90| 30| 90
Horizontal| 30| 90| 30| 90
120,000| Upflow| N/A| 90| N/A| 90
Horizontal| N/A| 90| N/A| 90

*NOTES:

  1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
  2. Two 45 degree elbows are equivalent to one 90 degree elbow.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

ACCESSORIES

KG7TC KITS

Description| SKU
2″ Concentric Vent Kit, US approved only| 904177
3″ Concentric Vent Kit, US approved only| 904176
2″ Concentric Vent Kit, Canadian and US approved| 904952
3″ Concentric Vent Kit, Canadian and US approved| 904953
2″ Side Wall Vent Kit| 904617
3″ Side Wall Vent Kit| 904347
U.S. LP Conversion Kit (0 to 10,000 ft.)| 905028
Canada LP Conversion Kit (0 to 4,500 ft.)| 905029
Bottom Return Filter 20 per Box, “B” Cabinet| 904916
Bottom Return Filter 20 per Box, “D” Cabinet| 904918
Side Return Filter Kit| 541036
Neutralizer Kit| 902377
Furnace Twinning Kit| 1010035

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (06/2019)
468F-0619

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals