BROAN FG7T Two Stage Fixed Speed High Efficiency Upflow/Horizontal And Downflow Gas Furance Owner’s Manual
- June 15, 2024
- Broan
Table of Contents
**BROAN FG7T Two Stage Fixed Speed High Efficiency Upflow/Horizontal And Downflow Gas Furance Owner’s Manual
**
FEATURES and BENEFITS
- I SEER: Energy efficient brushless DC (ECM) motor
- gives up to 1 SEER point efficiency gain in cooling 100% fired and tested: All units and each component arev tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free Low Boy Height: Easy to apply in low ceiling applications. works well with taller high SEER coils, sasier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life. 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off setings (60, 90, 120 and 180 seconds). 30 second post purge: Increases life of heat. exchanger
- Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartite technology. Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- High static blowers: All models equipped with high static blowers. 90 second cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE col.
- Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
- Variable speed blower kit: Upgradable to full variable speed with kit.
- LP convertible: Simple bumerantice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes : Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting Ilashes
- Integrated control board: Incorporates connections for electronic air deaner, humidifier and winning Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
- Blower Compartment : Insulated for ultra quiet operation.
- Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels
GAS FURNACE COMPONENTS
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Flame Roll-Out Switch
- Flame Sensor
- Furnace Control Board
- Gas Manifold
- Gas Valve
- Igniter
- Inducer Assembly
- Main Air Limit Switch
- Motor Choke (3/4 and 1HP only)
- Motor Control Board
- Motor Control Box
- Pressure Switch(s)
- Transformer
Upflow/Horizontal Gas Furnace
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Combustion Tube
- Flame Roll-Out Switch
- Flame Sensor
- Furnace Control Board
- Gas Manifold
- Gas Valve
- Igniter
- Inducer Assembly
- Main Air Limit Switch
- Motor Choke (3/4 and 1HP only)
- Motor Control Board
- Pressure Switch(s)
- Transformer
Downflow Gas Furnace
DIMENSIONS
*TA Model #’s| Dimension “A”| Dimension “B”| Dimension
“C”| Dimension “D”
---|---|---|---|---
060-23A1| 14 ¼| 10 ¾| 12 ⅝| 12 ⅞
080-24B1| 17 ½| 11 ¾| 15 ⅞| 16 ⅛
100-24B1
100-35C1| 21| 14| 19 ⅜| 19 ⅝
120-35C1
140-45$1| 24 ½| 15 ¼| 22 ⅞| 23 ⅛
FG7TA 80+ High Efficiency Upflow/Horizontal Series
*TK Model #’s| Dimension “A”| Dimension “B”| Dimension
“C”| Dimension “D”
---|---|---|---|---
060-23A1| 14 ¼| 10 ¾| 12 ⅝| 12 ⅞
080-24B1| 17 ½| 11 ¾| 15 ⅞| 16 ⅛
100-24B1
100-35C1| 21| 14| 19 ⅜| 19 ⅝
120-35C1
140-45$1| 24 ½| 15 ¼| 22 ⅞| 23 ⅛
FG7TK 80+ High Efficiency Downflow Series|
BLOWER PERFORMANCE – FG7TA/TK
FG7TA/TK – 80% AFUE, Two Stage Gas Furnace
Model Number| Heating Input (Btuh)| Motor Switch Setting|
External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise| CFM| Rise| CFM| Rise
4A/4+-060(C)-A1| 60000| 0| 0| 0| 0| | | | | | | | | | | | | | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| 600| –| 555| –| 510| | | | | | | | | | |
1| 1| 0| 0| 705| –| 670| –| 635| –| 600| –| | | | | | | |
0| 0| 1| 0| 775| 57| 740| 60| 705| –| 665| –| | | | | | | |
1| 0| 1| 0| 900| 49| 870| 51| 835| 53| 800| 56| 765| 58| 730| 61| 695| 64|
660| 67
0| 1| 1| 0| 950| 47| 920| 48| 890| 50| 855| 52| 825| 54| 795| 56| 765| 58|
730| 61
1| 1| 1| 0| 1000| 44| 970| 46| 940| 47| 910| 49| 880| 51| 850| 52| 820| 54|
790| 56
0| 0| 0| 1| 1075| 41| 1045| 43| 1015| 44| 985| 45| 960| 46| 925| 48| 900| 49|
870| 51
1| 0| 0| 1| 1110| 40| 1080| 41| 1055| 42| 1025| 43| 1000| 44| 975| 46| 945|
47| 920| 48
0| 1| 0| 1| 1170| 38| 1140| 39| 1115| 40| 1090| 41| 1060| 42| 1035| 43| 1010|
44| 985| 45
1| 1| 0| 1| 1210| 37| 1185| 38| 1160| 38| 1130| 39| 1105| 40| 1080| 41| 1055|
42| 1025| 43
0| 0| 1| 1| 1520| 29| 1225| 36| 1200| 37| 1175| 38| 1150| 39| 1120| 40| 1095|
41| 1070| 42
1| 0| 1| 1| 1305| 34| 1280| 35| 1255| 35| 1230| 36| 1205| 37| 1180| 38| 1155|
38| 1130| 39
0| 1| 1| 1| 1350| 33| 1230| 36| 1305| 34| 1285| 35| 1260| 35| 1240| 36| 1215|
37| 1195| 37
1| 1| 1| 1| 1440| 31| 1400| 32| 1365| 33| 1230| 36| 1295| 36| 1255| 35| 1220|
36| 1185| 38
4A/4+-080(C)-B1| 80000| 0| 0| 0| 0| | | | | | | | | | | | | | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| | | | | | | | | | | | | | | |
1| 1| 0| 0| 725| –| | | | | | | | | | | | | |
0| 0| 1| 0| 810| –| | | | | | | | | | | | | |
1| 0| 1| 0| 940| 63| 890| –| 845| –| 795| –| 750| –| 700| –| | | |
0| 1| 1| 0| 990| 60| 945| 63| 905| 65| 860| –| 820| –| 775| –| 735| –| 690| –
1| 1| 1| 0| 1055| 56| 1015| 58| 970| 61| 930| 64| 890| –| 845| –| 805| –| 760|
–
0| 0| 0| 1| 1135| 52| 1095| 54| 1055| 56| 1010| 59| 960| 62| 930| 64| 890| –|
850| –
1| 0| 0| 1| 1185| 50| 1145| 52| 1105| 54| 1065| 56| 1030| 58| 990| 60| 950|
62| 910| 65
0| 1| 0| 1| 1250| 47| 1210| 49| 1170| 51| 1135| 52| 1095| 54| 1055| 56| 1020|
58| 980| 60
1| 1| 0| 1| 1290| 46| 1255| 47| 1220| 49| 1180| 50| 1145| 52| 1110| 53| 1075|
55| 1040| 57
0| 0| 1| 1| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160| 51| 1120| 53| 1085|
55| 1045| 57
1| 0| 1| 1| 1350| 44| 1315| 45| 1280| 46| 1245| 48| 1205| 49| 1170| 51| 1135|
52| 1100| 54
0| 1| 1| 1| 1390| 43| 1350| 44| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160|
51| 1125| 53
1| 1| 1| 1| 1420| 42| 1380| 43| 1345| 44| 1310| 45| 1270| 47| 1235| 48| 1200|
49| 1160| 51
Note
- Motor Switch Ich Settings are for heating speeds using HEAT switches 1.. 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7. & 8
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are not recommended.
BLOWER PERFORMANCE – FG7TA/TK Continued
G7TA/TK – 80% AFUE, Two Stage Gas Furnace
**Model Number| Heating Input (Btuh)| Motor Switch Setting|
External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise| CFM| Rise| CFM| Rise
** 4A100(C)-B1|
**** 100000| 0| 0| 0| 0| 905| –| 890| –|
805| –| 780| –| | | | | | | |
1| 0| 0| 0| 980| –| 930| –| 900| –| 835| –| 820| –| 800| –| 715| –| 670| –
0| 1| 0| 0| 1095| –| 1015| –| 980| –| 915| –| 895| –| 870| –| 810| –| 765| –
1| 1| 0| 0| 1160| 64| 1100| –| 1065| –| 1035| –| 995| –| 940| –| 895| –| 865|
–
0| 0| 1| 0| 1230| 60| 1195| 62| 1170| –| 1110| –| 1075| –| 1060| –| 995| –|
970| –
1| 0| 1| 0| 1315| 56| 1275| 58| 1240| 60| 1195| 62| 1160| 64| 1140| 65| 1115|
–| 1075| –
0| 1| 1| 0| 1345| 55| 1310| 57| 1280| 58| 1250| 59| 1220| 61| 1190| 62| 1140|
65| 1115| –
1| 1| 1| 0| 1445| 51| 1390| 53| 1350| 55| 1315| 56| 1280| 58| 1250| 59| 1230|
60| 1185| 63
0| 0| 0| 1| 1490| 50| 1430| 52| 1420| 52| 1380| 54| 1340| 55| 1310| 57| 1280|
58| 1275| 58
1| 0| 0| 1| 1550| 48| 1510| 49| 1475| 50| 1450| 51| 1420| 52| 1375| 54| 1340|
55| 1325| 56
0| 1| 0| 1| 1600| 46| 1270| 58| 1540| 48| 1500| 49| 1475| 50| 1445| 51| 1425|
52| 1385| 53
1| 1| 0| 1| 1640| 45| 1605| 46| 1570| 47| 1550| 48| 1525| 49| 1490| 50| 1460|
51| 1430| 52
0| 0| 1| 1| 1690| 44| 1665| 44| 1630| 45| 1600| 46| 1570| 47| 1550| 48| 1515|
49| 1490| 50
1| 0| 1| 1| 1755| 42| 1730| 43| 1680| 44| 1660| 45| 1640| 45| 1610| 46| 1575|
47| 1550| 48
0| 1| 1| 1| 1805| 41| 1770| 42| 1740| 43| 1715| 43| 1690| 44| 1655| 45| 1645|
45| 1605| 46
1| 1| 1| 1| 1860| 40| 1825| 41| 1790| 41| 1765| 42| 1745| 42| 1710| 43| 1695|
44| 1660| 45
**** 4A/4+-100(C)-C1|
**** 100000| 0| 0| 0| 0| 1125| 66| 1040|
–| 960| –| | | | | | | | | |
1| 0| 0| 0| 1205| 61| 1120| –| 1040| –| 960| –| | | | | | | |
0| 1| 0| 0| 1305| 57| 1225| 60| 1150| 64| 1070| –| 995| –| 915| –| | | |
1| 1| 0| 0| 1430| 52| 1350| 55| 1270| 58| 1190| 62| 1110| –| 1030| –| 950| –|
865| –
0| 0| 1| 0| 1525| 49| 1450| 51| 1375| 54| 1300| 57| 1225| 60| 1150| 64| 1075|
–| 1000| –
1| 0| 1| 0| 1620| 46| 1540| 48| 1465| 51| 1390| 53| 1315| 56| 1240| 60| 1165|
64| 1090| –
0| 1| 1| 0| 1695| 44| 1620| 46| 1545| 48| 1465| 51| 1390| 53| 1315| 56| 1235|
60| 1160| 64
1| 1| 1| 0| 1770| 42| 1700| 44| 1630| 45| 1555| 48| 1485| 50| 1410| 53| 1340|
55| 1265| 59
0| 0| 0| 1| 1875| 40| 1805| 41| 1730| 43| 1655| 45| 1580| 47| 1510| 49| 1435|
52| 1340| 55
1| 0| 0| 1| 1905| 39| 1840| 40| 1775| 42| 1710| 43| 1640| 45| 1575| 47| 1510|
49| 1445| 51
0| 1| 0| 1| 1980| 37| 1910| 39| 1845| 40| 1780| 42| 1715| 43| 1650| 45| 1580|
47| 1515| 49
1| 1| 0| 1| 2025| 37| 1960| 38| 1895| 39| 1830| 40| 1765| 42| 1700| 44| 1635|
45| 1570| 47
0| 0| 1| 1| 2085| 36| 2025| 37| 1960| 38| 1900| 39| 1840| 40| 1775| 42| 1715|
43| 1655| 45
1| 0| 1| 1| 2135| 35| 2070| 36| 2010| 37| 1945| 38| 1880| 39| 1815| 41| 1750|
42| 1685| 44
0| 1| 1| 1| 2200| 34| 2145| 35| 2090| 35| 2035| 36| 1980| 37| 1925| 38| 1870|
40| 1820| 41
1| 1| 1| 1| 2280| 32| 2225| 27| 2170| 34| 2115| 35| 2065| 22| 2010| 37| 1955|
38| 1900| 39
Notes:
- Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, 8 8.
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are not recommended.
BLOWER PERFORMANCE – FG7TA/TK Continued
FG7TA/TK – 80% AFUE, Two Stage Gas Furnace
**Model Number| Heating Input (Btuh)| Motor Switch Setting|
External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise| CFM| Rise| CFM| Rise
** 4A/4+-120(C )-C1|
**** 120000| 0| 0| 0| 0| 1125| –| 1040| |
| | | | | | | | | | |
1| 0| 0| 0| 1205| –| 1120| –| 1040| –| | | | | | | | | |
0| 1| 0| 0| 1305| –| 1225| –| 1150| –| 1070| –| | | | | | | |
1| 1| 0| 0| 1430| 62| 1350| –| 1270| –| 1190| –| 1110| –| 1030| –| | | |
0| 0| 1| 0| 1525| 58| 1450| 61| 1375| 65| 1300| –| 1225| –| 1150| –| 1075| –|
1000| –
1| 0| 1| 0| 1620| 55| 1540| 58| 1465| 61| 1390| 64| 1315| –| 1240| –| 1165| –|
1090| –
0| 1| 1| 0| 1695| 52| 1620| 55| 1545| 58| 1465| 61| 1390| 64| 1315| –| 1235|
–| 1160| –
1| 1| 1| 0| 1770| 50| 1700| 52| 1630| 55| 1555| 57| 1485| 60| 1410| 63| 1340|
66| 1265| –
0| 0| 0| 1| 1875| 47| 1805| 49| 1730| 51| 1655| 54| 1580| 56| 1510| 59| 1435|
62| 1340| 66
1| 0| 0| 1| 1905| 47| 1840| 48| 1775| 50| 1710| 52| 1640| 54| 1575| 56| 1510|
59| 1445| 62
0| 1| 0| 1| 1980| 45| 1910| 47| 1845| 48| 1780| 50| 1715| 52| 1650| 54| 1580|
56| 1515| 59
1| 1| 0| 1| 2025| 44| 1960| 45| 1895| 47| 1830| 49| 1765| 50| 1700| 52| 1635|
54| 1570| 57
0| 0| 1| 1| 2085| 43| 2025| 44| 1960| 45| 1900| 47| 1840| 48| 1775| 50| 1715|
52| 1655| 54
1| 0| 1| 1| 2135| 42| 2070| 43| 2010| 44| 1945| 46| 1880| 47| 1815| 49| 1750|
51| 1685| 53
0| 1| 1| 1| 2200| 40| 2145| 41| 2090| 43| 2035| 44| 1980| 45| 1925| 46| 1870|
48| 1820| 49
1| 1| 1| 1| 2280| 39| 2225| 40| 2170| 41| 2115| 42| 2065| 43| 2010| 44| 1955|
45| 1900| 47
**** 4A/4+-140(C)-$1|
**** 140000| 0| 0| 0| 0| 1395| –| 1350| –|
1305| –| 1260| –| 1210| –| 1165| –| | | |
1| 0| 0| 0| 1465| –| 1420| –| 1375| –| 1330| –| 1290| –| 1245| –| 1200| –| |
0| 1| 0| 0| 1555| 67| 1510| 69| 1470| –| 1425| –| 1380| –| 1340| –| 1295| –|
1250| –
1| 1| 0| 0| 1625| 64| 1585| 65| 1540| 67| 1500| 69| 1460| –| 1415| –| 1375| –|
1335| –
0| 0| 1| 0| 1690| 61| 1650| 63| 1610| 64| 1570| 66| 1530| 68| 1485| 70| 1445|
–| 1405| –
1| 0| 1| 0| 1760| 59| 1715| 60| 1670| 62| 1625| 64| 1575| 66| 1530| 68| 1485|
70| 1440| –
0| 1| 1| 0| 1835| 57| 1790| 58| 1745| 59| 1695| 61| 1650| 63| 1605| 65| 1555|
67| 1510| 69
1| 1| 1| 0| 1885| 55| 1840| 56| 1790| 58| 1745| 59| 1700| 61| 1655| 63| 1610|
64| 1565| 66
0| 0| 0| 1| 1945| 53| 1900| 55| 1850| 56| 1805| 57| 1760| 59| 1710| 61| 1665|
62| 1620| 64
1| 0| 0| 1| 1950| 53| 1905| 54| 1860| 56| 1820| 57| 1775| 58| 1735| 60| 1690|
61| 1650| 63
0| 1| 0| 1| 2075| 50| 2030| 51| 1990| 52| 1945| 53| 1900| 55| 1855| 56| 1810|
57| 1770| 59
1| 1| 0| 1| 2125| 49| 2085| 50| 2040| 51| 2000| 52| 1955| 53| 1910| 54| 1870|
55| 1825| 57
0| 0| 1| 1| 2170| 48| 2130| 49| 2090| 50| 2045| 51| 2005| 52| 1965| 53| 1925|
54| 1880| 55
1| 0| 1| 1| 2215| 47| 2180| 48| 2140| 48| 2105| 49| 2070| 50| 2035| 51| 2000|
52| 1965| 53
0| 1| 1| 1| | | | | | | | | 2225| 47| 2165| 48| 2100| 49| 2040| 51
1| 1| 1| 1| | | | | | | | | | | 2170| 48| 2120| 49| 2065| 50
Note
- Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5. 6. 7.48:
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises that are shaded in grey are not recommended.
- Temperature rises in the table are approximate. Actual temperature rises may vary
MODEL IDENTIFICATION CODE
SPECIFICATIONS
FG7TA/TK MODEL NUMBERS| **060C-23A1| ****080C-24B1|
****100C-24B1| ****100C-35C1| ****120C-35C1| ****140C-45D1
---|---|---|---|---|---|---
)NPUT – BTUH (A)| 60,000 / 39,000| 80,000 / 52,000| 100,000 / 65,000| 100,000
/ 65,000| 120,000 / 78,000| 140,000 / 91,000
(EATING CAPACITY – BTUH| 48,000 / 31,200| 64,000 / 41,600| 80,000 / 52,000|
80,000 / 52,000| 96,000 / 62,400| 112,000 / 72,800
AFUE**| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
BLOWER $ X 7| 10 X 6| 11 X 8| 11 X 8| 11 X 10| 11 X 10| 11 X 10
MOTOR (.0. – 3PEED – 4YPE| 1/2 – BL$C| 1/2 – BL$C| 3/4 – BL$C| 3/4 – BL$C| 3/4
– BL$C| 1 – BL$C
MOTOR &LA| 6.2| 6.2| 8.7| 8.7| 8.7| 11.7
2ATED EXT. 30 – )N. 7.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
4EMPERATURE 2ISE 2ANGE – Ž&| 25-55| 30-60| 30-60| 35-65| 35-65| 40-70
3HIPPING 7EIGHTS| 115LBS| 110LBS| 120LBS| 125LBS| 135LBS| 155LBS
ACCESSORIES
FG7TA/TK KITS
Description| SKU
&IXED SPEED -TO- VARIABLE SPEED| 904880
“A” CABINET DOWNflOW SUB BASE KIT| 902974
“B”, “C”, “$” CABINET DOWNflOW SUB BASE KIT| 904911
5.3. L0 CONVERSION KIT (0 TO 10,000 FT.)| 904914
CANADA L0 CONVERSION KIT (0 TO 4,500 FT.)| 904915
BOTTOM RETURN fiLTER 20 PER BOX, “A” CABINET| 903088
BOTTOM RETURN fiLTER 20 PER BOX, “B” CABINET| 904916
BOTTOM RETURN fiLTER 20 PER BOX, “C” CABINET| 904917
BOTTOM RETURN fiLTER 20 PER BOX, “$” CABINET| 904918
3IDE RETURN fiLTER KIT| 541036
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (10/2015)
www.broanhwac.net Brand trademark used under sounaa Nortek Global HVAC, LLC. All Rights Reserved. 819C-0614 (Replaces 819C-0210)