BROAN FG7MQ Gas Furnace Owner’s Manual
- June 15, 2024
- Broan
Table of Contents
BROAN FG7MQ Gas Furnace
IMPORTANT INFORMATION
Fully Modulating, Variable Speed, Condensing Upflow/Horizontal Gas Furnaces
Induced Draft – 97.0 AFUE Input 60,000 – 120,000 Btuh
The high efficiency upflow gas furnace may be installed free
standinginautility room,basement,orenclosedinanalcove or closet.
Upflow/horizontal units come ready for upflow or horizontal application.The
extended flush jacket provides a pleasing “appliance appearance.” Design
certified by CSA for application in Canada and the United States.
FEATURES and BENEFITS
- SEER: Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
- Modulating heating operation Includes:
- Modulating gas valve from 100% to 50% input in 5% increments.
- Time proportioning modulation down to 15%.
- Variable speed inducer and blower.
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Uniquecornerpostdesign assures product will arrive to the homeowner dent free.
- 30 second blower delay: At start-up assures a warm duct temperatureatfurnacestart-up.Adjustablebloweroffsettings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitridetype igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designedtofitthecomponents, all with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
- High Static Blowers: All models equipped with high static blowers.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavygaugealuminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
- 90 second fixed cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
- LP convertible: Simple burner orifice change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashess: Dedicatedlightfor flamesignal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
- Incorporates integrated control board : with connections for electronic air cleaner and humidifier.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
- Sealed Vestibule: Reducesburnerandinducer soundlevels.
- iQ Drive Thermostat: Provides modulation down to 15% and is required for furnace operation.
- Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
DIMENSIONS
*MQ Model #’s | Dimension “A” | Dimension “B” | Dimension “C” |
---|---|---|---|
060D-VB | 17 1/2 | 15 7/8 | 16 1/8 |
080D-VC | 21 | 19 3/8 | 19 5/8 |
100D-VC
120D-VD| 24 1/2| 22 7/8| 23 1/8
MODEL IDENTIFICATION CODE
LOCATION OF FURNACE COMPONENTS
*UPFLOW / HORIZONTAL FURNACE (MQ SERIES)**
SPECIFICATIONS
FG7MQ MODEL NUMBERS:| -060D-VB| -080D-VC| -100D-VC|
-120D-VD
---|---|---|---|---
Input – Btuh (a)| 60,000 / 30,000| 80,000 / 40,000| 100,000 / 50,000| 120,000
/ 60,000
Heating Capacity – Btuh| 58,200 / 29,100| 77,600 / 38,800| 97,000 / 48,500|
116,400 / 58,200
AFUE| 97.0| 97.2| 97.4| 97.0
Blower D x W| 11 x 8| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 – Variable| 3/4 – Variable| 3/4 – Variable| 1 –
Variable
Motor FLA| 6.2| 8.7| 8.7| 11.70
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70
Shipping Weights| 130lbs| 140lbs| 150lbs| 165lbs
iQ Controller Kit
Description | Sku |
---|---|
iQ Controller kit | 920621* |
AIRFLOW DATA
Gas Input Rate (Btuh)| Target CFM for Selected Circulating Air
Temperature Rises, F
---|---
45| 50| 55| 60| Constant
Full Input| Minimum Input| Full Input| Minimum Input|
Full Input| Minimum Input| Full Input| Minimum Input
60,000| 1,110| 635| 1,000| 560| 940| 515| 850| 470| 950
80,000| 1,480| 850| 1,345| 740| 1,255| 685| 1,140| 625| 1,300
100,000| 1,850| 1,050| 1,680| 925| 1,565| 855| 1,460| 780| 1,760
120,000| 2,225| 1,270| 2,020| 1,115| 1,890| 1,025| 1,730| 940| 2,100
NOTE: This table lists the High and Low target CFMs for each maximum
input rate and temperature rise. If the target CFM is more that 1,600 CFM, it
is recommended that two return air openings into the furnace be used.
NOTE: The blower operating range is .1″ to .8″ ESP in wc.
MAXIMUM PIPE LENGTH CHART
FURNACE MODELS (BTU)| FURNACE INSTALLATION| SINGLE VENT PIPE
LENGTH (FT.) with 1 long radius elbow| DUAL VENT PIPE LENGTH (ft.)
with 1 long radius elbow on each pipe
---|---|---|---
OUTLET 2” Diameter| OUTLET 3” Diameter| INLET/OUTLET
2” Diameter| INLET/OUTLET 3” Diameter
60,000| Upflow| 50| 80| 50| 80
Horizontal| 40| 80| 40| 80
80,000| Upflow| 60| 90| 60| 90
Horizontal| 50| 90| 50| 90
100,000| Upflow| 50| 90| 50| 90
Horizontal| 40| 90| 40| 90
120,000| Upflow| N/A| 90| N/A| 90
Horizontal| N/A| 70| N/A| 70
*NOTES:
- Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Two 45° elbows are equivalent to one 90° elbow.
- Subtract 5ft for each 2” tee and 8ft for each 3” tee.
- This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.
- The minimum length for 2” or 3” diameter vent pipe is 5 ft.
ACCESSORIES
FG7MQ KITS
Description| SKU
2″ Concentric vent kit| 904177
3″ Concentric vent kit| 904176
2″ Side wall vent kit| 904617
3″ Side wall vent kit| 904347
U.S. LP Conversion kit (0 to 10,000 ft.) for US and Canada| 904950
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036
Neutralizer kit| 902377
Outdoor sensor for conventional heat pump| 920938
Features
Nortek Global HVAC, LLC will furnish a replacement for any part of this
product which fails in normal use and service within the terms and conditions
of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2016)
212D-0816 (Replaces 212D-0914)
www.broanhvac.net Broan® trademark used under
license.
© Nortek Global HVAC, LLC. All Rights Reserved.