KLARSTEIN 10035168 Wonder Wall Air Art Infinity Infrared Heater Instruction Manual

June 4, 2024
Klarstein

KLARSTEIN 10035168 - 1

WONDERWALL AIR

ART INFINITY

Infrared Heater

10035168   10035169   10035170   10035171
10035172   10035173

KLARSTEIN 10035168 - 2 KLARSTEIN logo
g1

www.klarstein.com

Note: The device is not suitable for use as a primary heat source.

Dear Customer,

KLARSTEIN 10035168 - QR Code

Congratulations on purchasing this equipment. Please read this manual carefully and take care of the following hints to avoid damages. Any failure caused by ignoring the mentioned items and cautions mentioned in the instruction manual are not covered by our warranty and any liability. Scan the QR code to get access to the latest user manual and other information about the product.


TECHNICAL DATA

Item number

| Power| Power supply| Dimensions
---|---|---|---
10035168
10035171| 300 W (±10%)| 220-240 V
~ 50 Hz|

505x595x16 mm

10035169
10035172

| 580 W (±10%)| 595x900x16 mm
10035170
10035173| 720 W (±10%)|

595x1195x16 mm


PRODUCT DATA SHEET

Model identifier(s): 10035168, 10035171
Item

Symbol

|

Value

| Unit| | Item|

Unit

Heat output| | Type of heat input, for electric storage local space heaters only
Nominal heat output|

Pnom

|

0.3

| kW| | manual heat charge control, with integrated thermostat|

no

Minimum heat output
(indicative)|

Pmin

|

0.3

| kW| | manual heat charge control with room and/or outdoor temperature feedback|

no

Maximum continuous heat output|

Pmax,c

|

0.3

| kW| | electronic heat charge control with room and/or outdoor temperature feedback|

no

Auxiliary electricity consumption| | fan assisted heat output|

no

At nominal heat output
(fan motor)|

elmax

|

0.300

| kW| | Type of heat output/room temperature control
At minimum heat output
(fan motor)|

elmin

|

0.000

| kW| | single stage heat output and no room temperature control|

no

In standby mode|

elSB

|

0.000

| W| | Two or more manual stages, no room temperature control|

no

| | with mechanic thermostat room temperature control|

no

| with electronic room temperature control|

no

| electronic room temperature control plus day timer|

no

| electronic room temperature control plus week timer|

yes

| Other control options (multiple selections possible)
| room temperature control, with presence detection|

no

| room temperature control, with open window detection|

yes

| with distance control option|

no

| with adaptive start control|

no

| with working time limitation|

no

| with black bulb sensor|

no

Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

Model identifier(s): 10035169, 10035172
Item

Symbol

|

Value

| Unit| | Item|

Unit

Heat output| | Type of heat input, for electric storage local space heaters only
Nominal heat output|

Pnom

|

0,58

| kW| | manual heat charge control, with integrated thermostat|

no

Minimum heat output
(indicative)|

Pmin

|

0,0

| kW| | manual heat charge control with room and/or outdoor temperature feedback|

no

Maximum continuous heat output|

Pmax,c

|

0,58

| kW| | electronic heat charge control with room and/or outdoor temperature feedback|

no

Auxiliary electricity consumption| | fan assisted heat output|

no

At nominal heat output
(fan motor)|

elmax

|

0.580

| kW| | Type of heat output/room temperature control
At minimum heat output
(fan motor)|

elmin

|

0.000

| kW| | single stage heat output and no room temperature control|

no

In standby mode|

elSB

|

0.000

| W| | Two or more manual stages, no room temperature control|

no

| | with mechanic thermostat room temperature control|

no

| with electronic room temperature control|

no

| electronic room temperature control plus day timer|

no

| electronic room temperature control plus week timer|

yes

| Other control options (multiple selections possible)
| room temperature control, with presence detection|

no

| room temperature control, with open window detection|

yes

| with distance control option|

no

| with adaptive start control|

no

| with working time limitation|

no

| with black bulb sensor|

no

Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

Model identifier(s): 10035170, 10035173
Item

Symbol

|

Value

| Unit| | Item|

Unit

Heat output| | Type of heat input, for electric storage local space heaters only
Nominal heat output|

Pnom

|

0.72

| kW| | manual heat charge control, with integrated thermostat|

no

Minimum heat output
(indicative)|

Pmin

|

0.0

| kW| | manual heat charge control with room and/or outdoor temperature feedback|

no

Maximum continuous heat output|

Pmax,c

|

0.72

| kW| | electronic heat charge control with room and/or outdoor temperature feedback|

no

Auxiliary electricity consumption| | fan assisted heat output|

no

At nominal heat output
(fan motor)|

elmax

|

0.720

| kW| | Type of heat output/room temperature control
At minimum heat output
(fan motor)|

elmin

|

0.000

| kW| | single stage heat output and no room temperature control|

no

In standby mode|

elSB

|

0.000

| W| | Two or more manual stages, no room temperature control|

no

| | with mechanic thermostat room temperature control|

no

| with electronic room temperature control|

no

| electronic room temperature control plus day timer|

no

| electronic room temperature control plus week timer|

yes

| Other control options (multiple selections possible)
| room temperature control, with presence detection|

no

| room temperature control, with open window detection|

yes

| with distance control option|

no

| with adaptive start control|

no

| with working time limitation|

no

| with black bulb sensor|

no

Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany


SAFETY INSTRUCTIONS

  • Do not use the appliance until it is securely fixed as described in this manual.
  • Check that the voltage indicates on the data plate corresponds with that of the local network before connecting the appliance to the mains power supply.
  • If the supply cord is damaged, it must be replaced by a qualified engineer in order to avoid a hazard.
  • The fireplace heater must not be positioned directly under the power socket.
  • Keep furniture, curtains and other flammable material at least 1 meter away from the appliance.
  • Do not leave the appliance unattended during use.
  • Do not leave the appliance unattended whilst connected to the mains supply.
  • Keep out of reach of children and do not allow them to operate this appliance.
  • This appliance is intended for household use only and should not be used for industrial purposes.
  • Do not operate this appliance after a malfunction or after being damaged in any way.
  • Repairs to electrical appliances should only be performed by a qualified electrician.
  • Improper repairs may place user at serious risk.
  • Do not run the mains cable under carpets, rugs, etc.
  • Do not allow the mains cable to hang over sharp edges or come in contact with hot surfaces.
  • In order to avoid overheating, do not cover the heater.
  • Do not use this heater with a programmer, timer, separate remote control system or any other device that switches the heater on automatically, since a fire risk exists if the heater is covered or positioned incorrectly.
  • Never immerse the product in water or any other liquid for any reasons.
  • Do not use this heater in the immediate surroundings of a bath, a shower or a swimming pool.
  • Do not use the appliance outdoors.
  • Do not use if you have wet hands.
  • Never use the appliance on or near hot surfaces.
  • Do not operate with a damaged cord.
  • Before cleaning the appliance, make sure it is unplugged from the power and that it is completely cooled.
  • Do not clean the appliance with abrasive chemicals.
  • Never use accessories that are not recommended or supplied by the manufacturer. It could cause danger to the user or damage to the appliance.
  • This appliance is not intended for use by persons (including children) with reduced Physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.

CAUTION
Risk of burns! Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.


WALL INSTALLATION

Important installation instructions

  • Continuous operation shortens the service life of the heaters. If possible, the appliance should be paused every 12 hours.
  • Do not use the unit when the ambient temperature is above 20 °C, as high temperatures will affect performance.
  • The outlet should be at least 20 cm above the ground.
  • Keep the unit away from flammable and explosive materials.
  • Leave a safety distance of 30 cm around the unit to the front, top and rear. Leave a safety distance of 10 cm to the right and left around the unit.
  • During the first one or two days, new heaters may emit odours that are harmless to humans.

10035168 - WALL INSTALLATION 1


REMOTE CONTROL DISPLAY INDICATORS

10035168 - REMOTE CONTROL

  1. Slot number
  2. Daylight saving time
  3. Program start time
  4. Program end time
  5. Centigrade degree
  6. Target temperature
  7. Fahrenheit degree
  8. Battery low warning
  9. Heat mode
  10. Socket status
  11. Current temperature
  12. RF Connection status
  13. AM/PM
  14. Program type
  15. Day

OPERATION AND FUNCTIONS

Button [M]

  • Press the [M] button switch between System time/Thermostat
  • Press and hold the [M] button under certain program slot to initiate a programming into the slot.

|
---|---

System

|

Thermostat

Button [OK]

  • Press [OK].
  • Choose the 1,2,3,4 slot. Press [OK] to turn on/off the slot.
  • Under programming or setting status, press the OK button to confirm and proceed to next step.

Button [+] and [-]

  • Choose the program slots.
  • Press button increase or decrease, the digit in programming and setting mode, press and hold [-] or [+] to fast increase/decrease.

Pair to control box

  1. Press and hold [+] and [-] simultaneously to start pairing. The CONNECT icon will blink on the display to indicate that the remote is attempting to connect to the unit.
  2. Turn on the heater at the side switch. The unit will now be in pairing mode for 60 seconds.
  3. Wait until the CONNECT symbol stops flashing and lights up permanently in the display. The remote control is now connected to the heater.

Note: The remote control only works within a radius of 10 meters from the unit. Establishing the connection usually takes 5 seconds.


QUICK START

Manual Override

Press the [OK] button repeatedly to select one of the following functions:

  • Manual temperature setting
  • OFF
  • ON

Note: Manual operation override all slot programs, and set all running slots into OFF status. Vice verse, turning on slots program will erase all manual setting.

Manual operation will features in the switch ON/OFF icons stay on while slot program will feature in the ON/OFF icons flashing.

| |
---|---|---
Manual switch-off of the system (the symbol lights up continuously)| Switching on the system manually (the symbol lights up continuously)| Manual setting of the temperature (the symbol lights up continuously)

Program on-the-run

Activate either of the slots program will erase the manual setting, and execute the slot program instead.

  1. The flashing MODE symbol indicates that the preset program for slot 3 is currently active.
  2. The flashing ON/OFF symbol indicates that the heater is currently controlled by a program.

Display on System page when program is on-the-run

Weekly program                                     Slot program

10035168 - Program on-the-run 2

  1. In thermostat mode, press [+] or [-].
  2. Select the programme position to be programmed and confirm with [OK].
  3. Press [+] or [-] and confirm the target temperature with [OK].
  4. Set the day of the week for the start time (ST) with +/-.
  5. Set the exact start time (hour and minutes) with +/-.
  6. Set the day of the week for the end time (ET) to +/-.

Set the exact end time (hour and minutes) with +/- and confirm with [OK]. Programming is now complete.

Set the start time (ST) and end time (ET) for several days.

The timer can either be programmed for all days the same or for individual days separately. There are 3 weekday modes. The display shows the following:

10035168 - Set Time 1

| 10035168 - Set Time 2| 10035168 - Set Time
3
---|---|---
Every day| Working day|

Weekend

In the circumstance you choose 3 types of day modes above in the ST programming, the ET will follow the selected ST day. the switch will be powered on/off base the time you programmed for your every routine.

Set the start time (ST) and end time (ET) for certain days

10035168 - Set Time 4

| 10035168 - Set Time 5
---|---

ST: Specific day to start

|

ET: Any day in the week to end

If you choose a specific day in a week as ST, then you can choose any day as ET. the switch will be turned ON/OFF base on the specific ST day and time to ET. day and time in a range of one week, and the program will repeat every week.

Display slot info

Users can view their programmed time or temperature by selecting the slot in program mode, user are allow to close or open the slot easily.

  1. Go the programme mode.
  2. Select the target slot you want to view, the programmed start time and end time will scroll in 1 second and repeat, all other information is displayed as well.
  3. Press the OK button to turn off this slot, press again to recover the slot.

Open-window mode

Note: Open-window mode when running overrides all modes.

  • If the temperature in the room drops by more than 6 °C within 20 minutes, the device interprets this as an open window and the heating switches off automatically.
  • As long as the mode is active, OPEN flashes in the display.
  • Press any button on the remote control to return to the manual setting mode.

Battery change

  • Remove the cover of the battery compartment.

  • Replace the old batteries with 2 new AA batteries and close the battery compartment again.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.

This product contains batteries. If there is a legal regulation for the disposal of batteries in your country, the batteries must not be disposed of with household waste. Find out about local regulations for disposing of batteries. By disposing of them in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences.


DECLARATION OF CONFORMITY

Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.

10035168 - UKCAImporter for Great Britain:
Berlin Brands Group UK Ltd
PO Box 1145
Oxford, OX1 9UW
United Kingdom

Hereby, Chal-Tec GmbH declares that the radio equipment type Wonderwall Air Art is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: use.berlin/10035168

For Great Britain: Hereby, Chal-Tec GmbH declares that the radio equipment type Wonderwall Air Art is in compliance with the relevant statutory requirements. The full text of the declaration of conformity is available at the following internet address:
use.berlin/10035168

KLARSTEIN logo g2

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Klarstein User Manuals

Related Manuals