nordlux Lonstrup 32 Wall Light Instruction Manual
- June 15, 2024
- nordlux
Table of Contents
nordlux Lonstrup 32 Wall Light
Product Information
Specifications
- IP Rating: IP4X (for cables, etc.)
- IP Rating: IPX4 (for lamp operation/safety)
- Maximum Wattage: 60W
- Class: II (double insulated)
Product Usage Instructions
Installation
- The lamp is designed for direct/fixed installation to the mains.
- Please follow the provided mounting instructions and do not discard them.
Connection
The lamp can be connected in parallel, allowing multiple lamps to be arranged together.
Safety
- Ensure that the maximum wattage specified is not exceeded.
- For Class II lamps, there is no need to connect the lamp to the grounding cable of the installation.
FAQ
Q: What is the maximum wattage for this lamp?
- A: The maximum wattage for this lamp is 60W.
Q: Can I connect multiple lamps?
- A: Yes, you can connect multiple lamps in parallel.
Q: Is it necessary to connect the lamp to the grounding cable?
- A: For Class II lamps, there is no need to connect the lamp to the grounding cable of the installation.
INSTALLATION INSTRUCTIONS
- IP4X: Protected against solid objects with a diameter of 1.0 mm or more. Protected against contact with dangerous parts with wires, etc.
- IPX4: Raindrops falling from any angle will not affect the function/safety of the lamp.
- The lamp is only suitable for connecting directly to the mains.
- MAX 60W Do not exceed the maximum wattage.
- The mounting instruction must not be discarded.
- IMPORTANT! Always shut off power to the circuit before starting installation work. In some countries, electrical installation work may only be carried out by an authorized electrical contractor.
- Contact your local electricity authority for advice.
- Class II: The lamp is double-insulated and does not need to be connected to the yellow/green earth wire.
- Parallel arranging is possible.
- Disposal of waste equipment by users in private households in the European Union. This symbol indicates that this product must not be disposed of with your other household waste.
- Electrical and electronic equipment contain substances that may cause damage to human health and the environment if not recycled correctly.
- It is your responsibility to hand over to a designated collection point for recycling of waste electrical and electronic equipment.
- When handing over for correct recycling you help to prevent these products from straining nature and the environment unnecessarily and protect human health.
- For more information regarding correct disposal, please contact your local city office, your household waste disposal service, or the store where you purchased this product.
- In the Nordic Countries, outdoor lights must be mounted by an authorized electrician.
INSTRUCTIONS
- Please read these instructions carefully before attempting to install this fitting. It is advisable to keep these instructions in a safe place for future reference.
- If this fitting is installed by a contractor, the contractor should ensure that the customer has a copy of these instructions.
Sensor specifications
- Voltage: 230 volts AC
- Max load: 100 watt maximum
- The angle of detection: 100 degrees
- Lux operation: Night-time operation <15 lux or daytime in test mode
- Time on: 1 min. (approx.) from initial triggering.
- NOTE! If triggered within this period, another 1 is added to time. already run.
- Manual override: This can be activated by switching off-on off-on (twice) using the fused spur switch. This will switch the light on for 5 hours.
- Max. detection range: Up to 8 meters approx. depending on weather conditions and mounting height.
- NOTE! The 8m detection range applies when a person is walking across the detection area, not walking towards the sensor.
- If a person is walking towards the sensor and 1.5m to the left or right of it, the detection range is typically between 4m and 6m
- Mounting height : 1.5 to 2 metres approx.
- Ambient operating temp. range: -20° to +35° Celsius
Operation
Normal Power-up
- On initial power-up, there is a 30-second warm-up period which allows the PIR (sensor) to stabilize.
Walk-test Mode
- During the first 10 seconds of the warm-up period (above), the unit can be put into walk-test mode by switching the mains power OFF ON OFF ON.
- The PIR (sensor) will now detect movement and switch the lamp on for 2 seconds duration for each detection made. This will give the user an indication of the area covered by the PIR sensor.
- If there is no detection for 30 seconds then the unit will automatically enter Normal Auto Mode (see below).
Normal Auto Mode
- The PIR (sensor) will only detect and switch the lamp on if the ambient light indicates that it is between dusk and dawn.
- The lamp will be illuminated for the pre-set time of 90 Seconds (the timing is re-set if additional triggers are detected).
Manual Override Mode
- With the unit in Normal Auto Mode, manual override can be activated by switching the main power OFF ON OFF ON.
- The lamp will now stay illuminated for 5 hours before automatically reverting to Normal Auto Mode.
Troubleshooting
When replacing the lamp or servicing the fitting, turn the power off at the mains and allow the lantern to cool.
- We congratulate you on your new outdoor lamp!
Guarantee
- The Nordlux Outdoor lamps in copper, brass, tombac, and galvanized are guaranteed for up to 15 years.
- This guarantee applies to extensive corrosion in the form of holes in the metal caused by rust.
- The guarantee is subject to the presentation of a receipt.
- There is no guarantee on the components that have been damaged by wear and tear or mistreatment of the lamps
Stainless steel
- Remember to take care of your lamp. Just follow the guidelines below.
- The shiny, uniform, and decorative surface of stainless steel makes it very suitable for outdoor use.
- It is an alloy consisting of iron, chrome, and nickel. During bath pickling, a thin, rustproof oxide layer forms on the surface.
- The surface is continually vulnerable to atmospheric conditions, and other effects of the close environment.
- This means that the lamp must be regularly maintained if its surface is to remain shiny and untarnished by rust.
- Before setting it up, treat your lamp with acid-free oil, and dry it off with a soft cloth. Repeat this three or four times a year.
- Stainless steel lamps are not recommended for use in aggressive environments such as coastal, agricultural, or industrial areas.
Copper, Brass, and Tombac fixtures
- Our copper, brass, and tombac fixtures are made from respectively solid copper, brass, and tombac. The mechanical machining will leave small scratches on the surface, as well as residues of rinse aid.
- This rapidly disappears in the patina process. After the first rain showers, the copper/brass/tombak surface will appear stained, but the aerated air and moisture will soon make the lamp appear with a dark brownish color.
- Over the years, the material copper will get a beautiful patina-green color, and brass/tombac will get a darker and more uniform color.
- The uniformity of the patina surface, as well as the rate at which the process occurs, is dependent on the environment that affects the fixture.
Hot-galvanized lamps
- The zinc treatment of the steel lamps is executed manually in plants. The temperature of the melted zinc is about 460 degrees. When the lamps are dipped in melted zinc a reaction between the metalls occurs, which develops alloys in the surface.
- The lamp and the components of the lamp are manually dipped in the hot zinc. This treatment leaves variations in the coating in the form of partly an uneven surface and partly minor formations of drops.
- Thin »zinc curtains« might also occur on the surface and they show as a thin film that hangs down from the edge of the lamp. This film can easily be removed or brushed off with a soft brush.
Condensation
- Condensation is a natural phenomenon arising under specific atmospheric conditions. Damp heat and cold air meet, which causes condensation of water on the surface.
- When water heats up it leads to rising water vapour, which will be able to affect electric components.
- Condensation is not included by Nordlux warranty unless it is possible to prove that a technical /production error in the lighting causes entry of water.
In case of condensation please check:
- If the lighting is mounted according to instructions. Washers should seal tightly. Make sure to tension screws and lenses.
- In garden lighting rising damp from the ground may cause condensation in the metal post. This problem can be defeated by filling sealing material into the metal post.
Aluminum fixtures
- Our aluminum light fixtures are made from die-cast and/or extruded aluminum, where the light fixture’s design determines whether both types of materials or just one of them, are used for different parts of the same light fixture.
- Aluminum light fixtures in raw aluminum are subsequently coated with a special clear coat, which seals the surface to safeguard against corrosion.
- Painted aluminum light fixtures are powder-coated and have a uniform and smooth surface. To avoid the light fixture tarnishing, it is recommended to clean and wipe the light fixture after mounting and repeat this process 3-4 times each year.
- This is done with a regular cleaning agent. Black light fixtures which are bleached by strong sunlight can also benefit from treatment with silicone spray as needed, to maintain the black color.
- Mounting light fixtures in coastal, agricultural, or industrial areas are not recommended, as these aggressive surroundings may cause the light fixture to corrode, which may entail spalling, bubbles in the surface, and a whitish incrustation on the light fixture’s surface.
- Drainage holes must be kept free of impurities if any.
- BEFORE ASSEMBLING THE BOLLARD AGAIN DO REMEMBER TO WIPE OFF ALL PARTS!
- www.nordlux.com
- Nordlux A/S Ostre Havnegade 34 9000 Aalborg
Documents / Resources
|
nordlux Lonstrup 32 Wall
Light
[pdf] Instruction Manual
Lonstrup 32 Wall Light, Lonstrup, 32 Wall Light, Wall Light, Light
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>