GENIE

Installation Instructions
Lift Connect™ Access Manager
Refer to Models Included
section for model and serial
number information

Introduction

Observe and Obey:
 This procedure shall be completed by a person trained and qualified on the repair ofthis machine.
 Immediately tag and remove from service a damaged or malfunctioning machine.
 Repair any machine damage or malfunction before operating the machine.

Before Starting Installation:
 Read, understand and obey the safety rules and operating instructions in the appropriate operator’s manual.
 Be sure that all necessary tools and parts are available and ready for use.
 Read this procedure completely and adhere to the instructions. Attempting shortcuts may produce hazardous conditions.

Note: These installation instructions only apply to the Genie models and serial number ranges listed within this document.

If you have any further questions regarding these instructions or need assistance, please contact Genie Product Support at one of the following telephone numbers:

United States: + 800 536 1800
Canada: + 425 881 1800

Europe:
UK regions
Nordic regions
Middle East / South Africa
French regions
German regions
BNL regions
IT / SE regions
Spanish regions| + 311 65799800
+ 311 65799801
+ 311 65799802
+ 311 65799803
+ 311 65799804
+ 311 65799805
+ 311 65799806
+ 311 65799807
Australia| + 61 7 3456 4444
Brazil| + 0 800 031 0100
South America – other
locations| + 56 9 6431 2110
All other locations| + 1 425 881 1800

Copyright © 2022 by Terex Corporation
First Edition: First Printing, November 2022
Genie is a registered trademark of Terex South Dakota, Inc. in the U.S.A. and many other countries.
“GS” is a trademark of Terex South Dakota, Inc.
“Lift Connect” is a trademark of Terex South Dakota, Inc.

Models Included

Model From serial number
GR from GR14-30931

from GRR-101
QS| from QS14-1653
GRC| from GRC14-1781

Note: Beacon bracket is required to install an access manager onto the machine. Verify if the machine has beacon bracket installed.
Refer to below table for machine specific beacon bracket to be ordered.

Model From serial number Genie partnumber Qty.
GR from GR14-30931 to
GR16P-41930 80085GT 1
38600GT 4
QS from QS14-1653 to
QS16P-2452 80085GT 1
38600GT 4
GRC from GRC14-1781 to
GRC16P-2482 124421GT 1
38600GT 4

Tools Required:

Cable tie gun or wire cutters
Drill motor
Deburring tool
Small flathead screwdriver
Wire crimper
Wire stripper
13/64 inch / 5 mm drill bit
11/32 inch / 9 mm Wrench

Components of Kit 1306517GT

Description Genie part number Qty.
Installation instructions 1311936GT 1
Access manager users guide 1312446GT 1
Forming, keypad, mount 1309477GT 1
Access management keypad 1296895GT 1
Access management harness, 1305083GT 1
Flat washer, #8, SAE, ZAG 1257390GT 4
Screw, HHC, 1/4 x .75, 8, ZAG 824059GT 2
Nylock nut, 1/4-20, C, ZAG 1274165GT 2
Screw, PHPM, 8-32 x 1, ZAG 1258189GT 2
Nylock nut, 8-32, 8, ZAG 1271081GT 2
Cable tie, 4″ BLK, Heat Resistant 21121GT 8

Procedure
Note: Perform this procedure on a firm, level surface with the machine in the stowed position.

  1. Turn the key switch to the off position and push in the red Emergency Stop button to the off position at the ground controls.

  2. Disconnect the battery pack from the machine.
    WARNING
    Electrocution/burn hazard.
    Contact with electrically charged circuits could result in death or serious injury. Remove all rings, watches and other jewelry.

  3. Locate the beacon bracket on the machine.

  4. Mark the locations on the beacon bracket to drill the required holes.
    Note: Refer to the Drilling Diagram that is appropriate for your machine.

  5. Using a 13/64 in / 5 mm drill bit, drill and deburr the holes required to mount the keypad mounting assembly.

  6. Install and secure the keypad mount onto the beacon bracket using the provided retaining fasteners.
    Genie part numbers 1309477GT, 824059GT, 1274165GT
    Genie GR Lift Connect Access Manager - Parts 11 mast assembly
    2 access manager keypad
    3 keypad mount bracket
    4 retaining fasteners
    5 telematics device
    6 beacon bracket
    7 keypad mount bracket fasteners

  7. Secure the keypad onto the keypad mount using the provided retaining fasteners.
    Genie part numbers 1296895GT, 1258189GT, 1257390GT, 1271081GT

  8. Open the ground controls compartment.

  9. Locate and disconnect Genie Lift Connect telematics device from the 12 pin gateway harness.

  10. Connect the telematics device harness connector to the 12 pin connector of access manager harness.
    Genie part number 1305083GT

  11. Connect the 12 pin connector of the access manager harness to the 12 pin gateway harness.
    Note: Harness connectors are keyed for proper installation.
    NOTICE
    Component damage hazard.
    Improper connections will result in damage to the telematics module and it is not covered under warranty.
    Genie GR Lift Connect Access Manager - harness
connector

  12. Route the 5 pin connector of access manager harness towards the access manager keypad harness and secure the harness.
    Note: Secure the cable using the provided cable ties.
    Genie part number 21121GT

  13. Connect the 5 pin access manager keypad harness connector to the 5 pin connector of access manager harness.

  14. Align white dots on the connector and push the plug together to connect the access manager harness to the keypad.

  15. Tighten the connector to hand tight.

  16. Connect the battery pack to the machine.

  17. Place the Access Manager user guide in the manual storage box located on the machine.
    Genie part number 1312446GT

Software Version
Note: Not all machines will require a software update.

  1. Verify the software revision on your machine.
  2. Turn the key switch to ground control and pull out the red Emergency Stop button to the on position.
  3. Read and record the software version displayed on the LCD screen.

Software Version
Note: Refer to the following chart to determine if the machine software requires updating.

Model Software Version
GR, GRC, QS GR, GRC, QS

Note: Models with a software version listed is the minimum requirement to support Access Manager and does not require an immediate software update.

Genie recommends updating the machine software to receive the latest updates and features available. Refer to the Genie Firmware website.
Note: Models with a lower revision level must update the system software. Refer to Firmware Site Download.

Firmware Site Download

  1. Access the firmware website address below:
    https://www.genielift.com/en/support/firmware

  2. From the drop-down menu, select the model that is appropriate for your machine.

  3. Update the software using the appropriate instructions for your machine.

Access Manager Activation

  1. Navigate to the Options menu on the machine and verify Lift Connect is selected.
  2. To complete activation of your Access Manager keypad please contact the Lift Connect team.
    mailto: AWP.LiftConnectSubscriptions@terex.com

Drilling Diagram

Genie GR Lift Connect Access Manager - Drilling Diagra

Genie GR Lift Connect Access Manager - GRC models

Part No. 1311936GT
Lift Connect™
Access Manager

Documents / Resources

| Genie GR Lift Connect Access Manager [pdf] Instruction Manual
GR Lift Connect Access Manager, GR, Lift Connect Access Manager, Connect Access Manager, Access Manager, Manager
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals