INSTRUCTION MANUAL DEHUMIDIFIER
OL-R190SP
SAFETY INFORMATION
- Install the dehumidifier on flat surface to minimize vibration and or noise.
- Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged.
- Insert the three-prong plug on the power cord into a matching electrically grounded outlet (115V/ 60 Hz, 15 A at least). Do not use an adapter. Never cut off the third prong. Do not use an extension cord.
- Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
- Never immerse the dehumidifier into water or other liquids.
- Do not put the dehumidifier close to heat-generating devices, including flammable or dangerous materials.
- Unplug the power supply before cleaning or storing the dehumidifier. Always grasp the plug (not the cord) to unplug.
- Do not put fingers or other items into air inlet or air outlet.
- Never insert any other objects into the dehumidifier body.
- Do not sit, stand or put heavy objects on the dehumidifier.
- This dehumidifier should only be used by adults who have read the manual and understand the operating procedure of the dehumidifier.
- The dehumidifier is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by an adult.
Never repair or remove plug and or power cord. Any repairs should be completed by qualified electrician or distributor.
SPECIFICATIONS
DEHUMIDIFIER
Model No.: OL-R 1 90SP
Voltage & Hertz| AC115V / 60Hz
Power Consumption& Current| 735W/7.0A @80°F, 60% RH
835W/8.0A @86°F, 80% RH
Refrigerant Charge| R410AJ17.9oz (510g)
Dehumidify Capacity| 93Pints/Day @80°F, 60% RH 160Pints/Day @86°F, 80% RH
Maximum Design Pressure| High Side: 522psig (3.6MPa)
Low Side: 240psig (1.65MPa)
BCSC| 15A
Compressor Input| RLA: 7.3A LRA:36.4A
Fan Motor Power| 0.214HP
CONFORMS TO UL STD.
60335-1&60335-2-40
CERTIFIED TO CSA STD.
C22.2 NO.60335-1&60335-2-40
FEATURES
Hot Gas Valve system for fast defrost
Easy to assemble and disassemble the housing for repair
With fast connector of hose , convenient for assembly and disassemble
Foldable handle ,easy to operate
Quick pump access in front for easy servicing
Tough semi-pneumatic wheel
DRAWINGS
NOTE:
- Do NOT obstruct the air inlet and/or outlet while the dehumidifier is running.
- Apart from the 17 ft long drain hose for pump drainage, the package also includes a 3.3 ft hose which is used for emergency drainage in the event of pump failure.
OPERATION INSTRUACTIONS
- Install the Handle
- Remove the handle from the buckle and flip the handle up 180° to align the hole position of the handle and the handle holder;
- Insert the corded bolts into the holes of the handle holder and the handle by pressing and holding the metal button on the top of the bolt.
- Release your finger when you have inserted the bolt to the latch. To Fold the Handle for Storage
- Pull out the bolt from the latch by pressing and holding the metal button on the top of the bolt;
- After removing both bolts from the latches, fold the handle down by 180°
and fix it to the buckle.
NOTE:
Press and hold the top knob of the bolt when you are trying to insert or pull out the bolts.
Otherwise, you may not be able to insert or pull out the bolts.
-
Position Your Dehumidifier
IMPORTANT
Transporting or storing the dehumidifier in a horizontal position is not recommended.
When the dehumidifier is placed in a horizontal position, the oil from the compressor can flow into the refrigerant coils and reduce the ability of the dehumidifier to function and possibly damage the dehumidifier. If the dehumidifier has been placed in a horizontal position, set it upright and let it stand for at least 24 hours before plugging it in.
For best results, operate your dehumidifiers in an enclosed area. Close all doors and windows that open for efficiency. Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the dehumidifier. -
Set Up the Drainage
This dehumidifier has an internal pump that will automatically drain the condensate out via the 17 ft long drain hose. The hose, stored on the back of the dehumidifier, is equipped with a quick-connect fitting for easy attachment to the drain outlet. Before turning on the dehumidifier, make sure the hose has been connected to the drain outlet.
- Uncoil the entire hose;
- Attach the end of the hose with the connect fitting to the drain outlet directly, until you hear a “click” sound;
- Place the unattached end in a sink, drain, bucket or outdoors — anywhere
that water can drain out safely. ( Ensure there are no kinks or other
obstructions that will stop the water to flow. )
NOTE:
• Ensure that water which runs to outdoors does NOT create a slip hazard.
• If you use a bucket or other container for water collection, check it regularly to prevent overflows.
• The drain hose for the water pump can drain up to 15ft vertically. More than 15ft may cause water back up to the pump resulting in leakage.
• When turning off the dehumidifier, please take the hose out from the water collection container to avoid the water back-flow causes water leakage.
• To remove the drain hose from the outlet, press and hold the buckle on the connect fitting and pull the hose out.
• The dehumidifier won’t drain without connecting the drain hose.
-
Plug in Electrical Cord
The dehumidifier needs to be plugged into a GFCl-protected 115 volt outlet rated for at least 15 amps. Uncoil the power cord from the winder and plug it firmly into a suitable outlet.
After plugged in, the dehumidifier will automatically enter into standby mode where the readout on the display screen is in dim light. -
Understand the Control Panel Power Button: When the machine is in the standby mode, the display screen will be displayed in low light LED.
To start the dehumidifier, press the power button. Concurrently, the display screen will light up and the unit will run in Auto mode ,the default humidity setting data is 10%RH,and the machine will start if the humidity condition meets the requirement of compressor operation.
Press the power button again to turn off the machine, and the fan will shut down in 1 minute later.
Timing Button: Press the timing button ,the display screen will show the current timing data, and then press Add button to increase the timing data or press Minus to decrease the timing data. Press one time to increase or decrease one hour . The timing indicator will light up after setting.
When the machine 1s in the standby mode, press the timing button to set the start-up time; when the machine is running, press it to set the shutdown time. The timing setting range is from 0 to 24 hours. If you set the timing data as “00” ,1t will cancel timing function ,the timing indicator will turn off.
Add Button: Press the Add button to increase humidity data or increase timing data .
When setting the humidity data , press the button for one time to increase 5%RH , you can set the humidity range from 10%-90% RH, and 5% RH for one step , it will cycle as below :
10%-15%-20%-25%-30%-35%-40%-45 %-50%-55%-60%-65%-70%- 7T5%-80%-85%-90%-10% °°
When setting the timing data , press the button for one time to increase 1 hour , you can set the timing range from 1-24 hours ,and 1 hour for one step. it will cycle as below:
01-02-03-04-05-::-23-24-00-01-02°::
Minus Button: Press the Minus button to decrease humidity data or decrease timing data .
When setting the humidity data , press the button for one time to decrease 5%RH , you can set the humidity range from 90%-10% RH, and 5% RH for one step , it will cycle as below :
90%-8 5 %-80%-75%-70%-65 %-60%-5 5%-50%-45 %-40%-35%-30%- 25 %-20%-15’%-10%-90% °°”
When setting the timing data , press the button for one time to decrease 1 hour , it will cycle as below:
24-23-22-2]-20°*:-02-01-00-24-23°::
Purge Button (Manual Drainage): Press and hold the PURGE button for 3-5 seconds to empty water from the pump reservoir. Use “PURGE” before moving the dehumidifier to avoid water spillage. The FULL indicator will light up after you pressed the PURGE button, which means the pump is working. 30 seconds later, the pump will stop working automatically and the FULL light will go off.
NOTE: During operation, the pump purges automatically via the drain hose when the reservoir is full.
Defrosting Indicator: The dehumidifier begins to defrost when Se the defrost indicator illuminates; the dehumidifier has stopped defrosting when the light is no longer illuminated. When defrosting is complete, the dehumidifier begins to dehumidify again automatically.
Water Full Indicator: The FULL indicator lights up 1 when the pump Is automatically draining the condensate from the reservoir when the reservoir is full, or 2 when the user manually drains the pump by pressing the PURGE button.
Display Screen: The default temperature display is Fahrenheit temperature. When the machine is in standby mode, press the power button for 5 seconds to switch to Celsius temperature. When the machine is running, it shows the temperature and humidity of the inlet air and outlet air. It displays the running time when it is in running mode; and displays the setting timing and setting humidity data when users set .
Memory Function: If there is a power outage or the unit shuts off ,it will auto restart to its original settings except timing ,once power Is restored .
Note :
when humidity of air inlet2setting humidity data +3%RH ,and the compressor 1s out of 3 minutes delay start protection , the fan will start immediately and the compressor will start in 3 seconds later when humidity of air inletS setting humidity data -3%RH , the compressor will stop working immediately ,and the fan will stop working in 1 minute later -
Smart Functions
Auto Drainage
Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
Wait 3 Minutes before Resuming Operation
To avoid any damage to the dehumidifier, the dehumidifier will not start operation following a complete cycle until after 3 minutes. Operation will automatically start after 3 minutes.
Auto Defrost
When the frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
Auto-Restart
lf the dehumidifier shuts off unexpectedly due to power being cut, the dehumidifier will restart with the previous function setting automatically when the power resumes.
AUTO DRAINAGE AND MAINTENANCE
Please disconnect the power supply before cleaning or conducting maintenance.
Cleaning: Clean the unit body with a soft damp cloth. Do not submerse or place
water on the unit or control panel. Water may damage the electronic components
of the unit. Do not use chemical solvent such as benzene, alcohol, gasoline or
other heavy-duty cleaner. The surface may become damaged or deformed.
Cleaning the Air Filter:
Step 1: Pull out the air filter gently.
Step 2: Use a vacuum cleaner to remove the dirt on the surface of the air
filter. If the air filter 1s exceptionally dirty, immerse it gently into warm
water (about 40°C) with a neutral detergent, rinse and dry it thoroughly.
Step 3: Insert the filter back into the unit.
Dehumidifier Storage:
- Push the purge button to empty the water before transportation or storage.
- Transport and store the machine upright.
- Stack machines in warehouse to save space.
TROUBLE SHOOTING GUIDE
Trouble | Possible Cause | Solution |
---|---|---|
Error Code: E1 | Copper head sensor failure | Replace it |
Error Code: E2 | Air inlet temperature and humidity sensor failure | Replace it |
Error Code: E3 | Air outlet temperature and humidity sensor failure | Replace it |
Error Code: E4 | Water pump failure or Water tank of water pump is full |
Replace it or check the water pump
Error Code: ES| 4-way valve failure| Replace it
Cautions:
If unit malfunctions turn off the unit_and unplug it immediately.
Please contact your distributor for service issues.
**** Do not dispose of electrical appliances in local landfills, or et
municipal waste locations. Many parts are recyclable.
Contact your local government for information regarding the collection systems