INTRODUCTION
Thank you/or choosing this cooker hood.

  • This instruction manual is designed to provide you with all required instructions related to the installation, use and maintenance of the appliance.
  • In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and usage.

SAFETY PRECAUTION

  • Never let the children operate the machine.

  • The cooker hood is for home use only, not suitable for barbecue,
    roast shop and other commercial purposes.

  • Clean the cooker hood according to the instruction manual and keep the unit from danger of burning. There is a fire risk if cleaning is not carried out in accordance with the instructions.

  • Please keep the kitchen room a good convection before connecting this appliance; Please check that the power supply cord is undamaged. A damaged supply cord must be replaced by qualified service personnel only.

  • Regulations concerning the discharge of air have to be fulfilled.

  • This appliance can be used by children aged from 8 years and above also the persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. &
    CAUTION: Accessible parts may become hot when used with a cooking appliance. Electrical Shock Hazard
    Only plug this unit into a properly earthed outlet. If you have doubts, seek advice from a suitably qualified engineer.

Hareware Included

EDENDIRECT-FSJT-RA-080302 30-Inch-Silver-Wall-
fig-1

Tools Reg_uired

  • Pencil
  • Hammer
  • Level
  • Measuring tape
  • Screwdriver
  • Electric powered drill or screwdriver 

INSTALLATION INSTRUCTIONS

Prepare for installation:

  • If you have an outlet to the outside, your cooker hood can be connected as above picture by means of an pipe (with an interior diameter of 150mm). If you don’t have an outlet to the outside, you can go with recirculation mode by using carbon filter. EDENDIRECT-FSJT-RA-080302 30-Inch-Silver-Wall-fig-4
  • Before installation, turn the unit off and unplug it from the outlet.
  •  The cooker hood should be placed at a distance of650~750 mm above the cooktop for the best effect . EDENDIRECT-FSJT-RA-080302 30-Inch-Silver-Wall-fig-5

T-SHAPED AIR OUTLET INSTALLATION METHOD

Place the T shaped air outlet bracket underneath the inner chimney bracket and fix the T shaped outlet on the T-shape outlet bracket with 2pcs screws. (See pie 1)

  1. Fix the pipe.
  2. Tight up the screw from two side of chimney to fix the T-shape outlet after installing the chimney. (See pie 2)

Choose a suitable adjustment according to the size of chimney and fix the adjustment with ST4*8 screws. (See pie 3)

AIR OUTLET INSTALLATION METHOD

Installation method/or 150mm

diameter pipe: insert the one-way -valve as the pie and fix the pipe.

Attention: The bump of the one­way-value must be upward.
Installation method/or 120mm diameter pipe: insert the damper as the picture and fix the converter before placing the duct.
The pipe near the air outlet need to be fully extended.