MARVEL MLRE224 24-In Professional Built-In Refrigerator Owner’s Manual
- June 4, 2024
- Marvel
Table of Contents
**MARVEL MLRE224 24-In Professional Built-In Refrigerator Owner’s Manual
**
Welcome to the Marvel Experience
Thank you for choosing our quality American-built product to add to your home. We are thrilled to welcome you to our growing community of Marvel owners, who trust in our products and our support.
The information in this guide is intended to help you install and maintain your new Marvel under counter model to protect and prolong its lifetime. We encourage you to contact our Technical Support team at 616-754-5601 with any questions.
Got a Marvelous Design
We would love to see how your Marvel product looks in its new home. Send us
photos at
marketing@marvelrefrigeration.com,
and we might feature your Marvel home design on our website and social media!
Tip: Click on any section below to jump directly there
Installation
Integrated Panel Dimensions
Integrated Panel Installation
INTEGRATED PANEL DIMENSIONS
NOTE
- Panel thickness may be 5/8″ or 3/4″
- Center the unit in the 24″ opening
- If the hinge side of the product is pressed against the adjacent cabinet, use a 5/8″ thick panel
- The window cutout is for glass door models only
- Do not use a solid door panel on a glass door model
Door Type | Maximum Panel Weight |
---|---|
Solid | 15 Ibs |
Frame Glass | 10 Ibs |
INTEGRATED DOOR PANEL INSTALLATION
Cut and prepare panels according to the information provided in the Integrated Panel Dimensions section.
CAUTION
It is important to use the factory provided grille that came with the product to assure proper air flow is maintained through the condenser. The use of a custom grille is not recommended and will void the warranty.
Step 1: Removing the Door and Hinges
Hold the door secure in the closed position and remove Hinge Pin from the
Upper Hinge using a 1/8” Hex Key tool. Slowly remove the door by sliding
outward away from the cabinet and lift to remove off the Lower Hinge. If
reversing the door, remove hinges from cabinet per Door Reversal Instructions.
Remove the hinge bushing from the adapter plate. A new bushing is included in the literature pack with your unit.
Step 2: Remove the Door Gasket
With the door laying on a flat surface and starting at a corner of the door,
remove the magnetic door gasket from the interior side of the door. Set the
gasket aside on a flat surface.
There are 10 holes in the gasket retainer extrusions (3 on each side and 2 at the top and bottom) which are used to fasten the panel to the front of the door. The screws are provided in the literature pack.
Step 3: Assemble the Panel to the Door
The preferred method of attaching the panel to the door is to clamp the panel
to the door so it cannot move while drilling the screw pilot holes. Use bar
clamps or “C” clamps with pads on the clamping surfaces that will not mar the
panel or the door. The custom panel should be flush with the top of the door
and centered along the width of the door. Drill holes through the gasket
extrusion using the 10 holes as pilot holes. Use the drill size from the chart
in the table below being careful not to drill through the front surface of the
panel. Fasten the panel to the door with the 10 screws provided in the
literature pack. Remove the clamps and replace the gasket in the gasket
extrusion channels of the door. Some force may be required to seat the gasket
into the channels. Be sure the gasket corners are seated properly.
Material Type | #10 Wood Screw |
---|---|
Hardwood | ⁄8″ (3.2 mm) Diameter. Pilot Hole |
Softwood 7 | ⁄64 (2.8 mm) Diameter. Pilot Hole |
INTEGRATED DOOR PANEL INSTALLATION
Step 4: Install the Door
If reversing the door swing, reinstall hinges per Door Reversal Instructions.
Carefully slide lower hinge bushing over bottom hinge pin. Install the new
upper hinge bushing into adapter plate.
Align hinge bushing with top hinge and reinstall upper hinge pin using 1/8” Hex Key so that the pin is flush.