VEVOR YOILP-HG0015A Drum Pump User Manual

June 15, 2024
VEVOR

VEVOR-logo

VEVOR YOILP-HG0015A Drum Pump

VEVOR-YOILP-HG0015A-Drum-Pump-product-image

Technical Support and E-Warranty Certificate www.vevor.com/support

DRUM PUMP
USER MANUAL
Model:YOILP-HG0015A,YOILP-D490

  • We continue to be committed to provide you tools with competitive price.
  • “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.

NEED HELP? CONTACT US!

  • Have product questions? Need technical support? Please feel free to contact us: [email protected]
  • This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

Warning

  1. Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating.
  2. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.

GENERAL SAFETY RULES

  1. Select the appropriate product type according to the liquid type.
  2. Always keep hazardous, flammable or combustible liquids, other fuels and cleaners out of reach of children. Keep stored hazardous, flammable or combustible liquids far from open flames or heat.
  3. A maintained fire extinguisher should be kept nearby when working with hazardous, flammable or combustible liquids.
  4. Adequate ventilation is essential! Clean up all spills immediately when pumping or handling flammable liquids.
  5. ABSOLUTELY NO SMOKING!
  6. DO NOT use torches or apply fire or flames to this pump, pump components or any containers used with this pump.
  7. Be sure that the discharge line is secure before pumping. An insecure discharge line may slide, possibly causing personal injury and/or property damage.
  8. Over-tightening non-metallic fittings will strip threads. Once fitting is “hand tight” turn one more full rotation, this is usually enough to prevent leaking. Thread sealant can be used on all threaded joints, including the delivery spout.
  9. Before each use, check hoses for weak or worn spots. Check the security of all connections.
  10. Regularly inspect the pump and components, performing routine maintenance when required.
  11. Dispel all liquids from the pump and components before performing routine maintenance.

SAVE THESE INSTRUCTIONS

MODEL AND PARAMETERS

Model YOILP- HG0015A YOILP- D490
Max. Flow Rate 280ml per time 300ml per time
Style Hand Press Type Hand Press Type
Available Drums 5~55gal NPT2,NPT1.5 5~55gal NPT2,NPT1.5
Material PP, ABS Steel
Application Used for Acids and Alkali, Urea, Water, DEF(Not for all kinds of
oil) Used for Diesel, Kerosene, Machine oil (Not for gasoline, paint and

water)

STRUCTURE DIAGRAM

  1. Discharge Spout
  2. Handle
  3. Pump Body
  4. Suction Tube Extension
  5. Suction Tube w/Strainer
  6. Base Suction Tube

COMPONENTS

VEVOR-YOILP-HG0015A-Drum-Pump-01 \(2\)

ASSEMBLY

Installation Preparation:

  1. Please prepare a carpet or mat to protect your floor you need to spread out all the accessories.
  2. Please prepare gloves to avoid being scratched by sharp parts that may occur during installation.
  3. Please open all the boxes to check that the accessories are complete and in good condition.
  4. If you need to use power tools to install this product, please set the speed to low speed in advance.
  • Step1:
    • Read and understand instructions before beginning. Flush with water prior to use. Use PTFE tape on all plastic threaded joints.
    • Connect the Handle (2) to the Pump Body (1) and lift the rod with Machine Screws (5), Lock Nuts (6) and Washers (7).VEVOR-YOILP-HG0015A-Drum-Pump-01 \(1\)
  • Step2 : Slide Retainer Nut (4) onto Discharge Spout (3).VEVOR-YOILP-HG0015A-Drum-Pump-01 \(2\)
  • Step3: Attach Discharge Spout (3) onto Pump Body (1) using Retainer Nut (4). Make sure to use PTFE tape.VEVOR-YOILP-HG0015A-Drum-Pump-01 \(3\)
  • Step4: Attach Suction Tube Extension (9) to bottom of Pump body (1). Make sure to use PTFE tape.VEVOR-YOILP-HG0015A-Drum-Pump-01 \(4\)
  • Step5 :Insert Suction Tube with Strainer (8) through Base Suction Tube (10),and then attach Suction Tube with Strainer (8) into Suction Tube Extension(9) . Make sure to use PTFE tape.(It’s already assembled)VEVOR-YOILP-HG0015A-Drum-Pump-01 \(5\)
  • Note: The whole suction tube can be retractable through the base suction tube.
  • Step6 :If necessary, the hose can be connected to the discharge spout and locked with a clamp,as shown below

Operation

  • Determine the proper length of the suction tube for your application and attach to the pump.
  • Insert the suction tube through the bung hole located on the container lid ,attach the bung nut located on the bottom of the pump to the container lid.
  • Pump the handle several times to prime the pump.
  • Continue pumping until the desired volume of solution is delivered.VEVOR-YOILP-HG0015A-Drum-Pump-01 \(7\)
  • Above is the YOILP-HG0015A installation, and the installation of the YOILP-D490 is the same as that of YOILP-HG0015A.

MAINTENANCE

  1. After each use of the product, it is recommended to clean it and keep it dry.
  2. When using this product to extract a variety of liquids, it is recommended to clean this product before extracting another liquid.
  3. If the pump has not been used for an extended length of time, or has had low usage the pump should be flushed and cleaned.

Gasket replacement operation:

  1. Remove the handle screw(1)
  2.  Remove the nut(2)
  3. Replace the gasket(3)
  4. Then install the above nuts, screws.

TROUBLESHOOTING

THE PUMP IS NOT WORKING

  1. Check the suction tubes to be sure they are airtight. The pump will not pump if the suction tube allows air to enter. Thread sealing PTFE tape is recommended during assembly.
  2. Rinse pump with water or the appropriate solution in regards to what was just pumped. Some chemicals may harden or cause the internal parts to swell, this prohibits the operation of the pump. You may need to open the pump body and clean the internal parts. While inside, visually review the vane for chemical permeation or swelling. If this has occurred replace the pump.

Sanven Technology Ltd.
Address: Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730
Made in China

Technical Support and E-Warranty Certificate www.vevor.com/support

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VEVOR User Manuals

Related Manuals