PRODUCT

USER MANUAL
Please read this user manual carefully before use,and keep it for future reference.

INTRODUCTION

CONGRATULATIONS ON YOUR CHOICE
Thank you and we are delighted you have chosen our ceiling tan for your home. Please read all the instructions carefully before assembly and use.

SAFETY NOTICES

WARNING / CAUTION

WARNING/CAUTION notice denotes a hazard. It
calls attention to installation procedure, operating procedure, maintenance procedure, or the like, that if not correctly pertormed or adhered to, could result in damage to this appliance, personal injury or death. Do not proceed beyond a

WARNING/CAUTION notice until the indicated conditions are fully understood and met

SAFETY SYMBOLS

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(1\)

SAFETY PRECAUTIONS

Please observe the following general safety precautions carefully before and during all phases of handling, installation, removal, operation and maintenance of this product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. We assumes no liability for customer’s failure to comply with these requirements.

SAFETY WARNING

  1. Read all instructions and safety information. Review assembly diagrams provided before installing your new ceiling fan.
  2. This fan must be installed by a licensed and qualified electrician.
  3. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  4. Young children should be supervised to ensure that they do not play with the appliance.
  5. All electrical works must only be undertaken after disconnection of the power by removing fuses or turning off the circuit breaker, to ensure all pole isolation of the electrical supply.
  6. Do not use outdoors where it could be exposed to water or moisture.
  7. This manual is not intended to instruct or assist untrained or unqualified persons to install this ceiling fan.
  8. It is the responsibility of qualified, licensed installer and user to apply common sense and care at all times during installation and operation.

HOW TO CHOOSE A PROPER LOCATION FOR THE CEILING FAN

  1. According to safety regulations, the lowest point of the fan blade must be at least 2.1 metres (7 feet) from the floor.

  2. For fan installed enclosed outdoors, the fan must be installed at least 1.5m from the perimeter of roof/ eaves of the enclosure to protect the product from direct or indirect rain water or sunlight.

  3. The chosen location for the fan must not allow the rotating blades to come into contact with any object.

  4. Please check carefully and make sure that ceiling joists are strong enough and of adequate size to support the weight of about 35kg.

  5. To reduce the risk of fire, electrical shock or personal injury, please make sure that the fan mounting bracket is directly supported from the building structure.
    Do not mount to an outlet box.

  6. The mounting plate must be firmly screwed to a load bearing building structure eg. a concrete must be securely nailed or screwed between the beams.

  7. Attach tan blades atter the tan motor housing is installed and properly secured. Keep the fan motor and fan blades in original package until it is ready to be installea.

  8. Check and confirm, after the fan is completely installed, that all connections are proper and secure to prevent the fan from falling or causing property damages or personal injury.

  9. Take care not to bend or damage the motor Drive Shaft or Fan Blades when handling or installing them. If such defect is noticed, please contact the Customer Service before installation of the ceiling fan.

  10. Fan, light kit and mounting plate must be earthed.

  11. Use of an unapproved remote control voids the warranty. Only use our remote control.

  12. Do not remote the fan from the ceiling after installation.

  13. Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before installing the tan and replacing led light.

UNPACK YOUR CEILING FAN

I pen the on ni anor da ge tens, Coming destomer service. Do not throw away the carton or other packaging material as it may be needed for warranty replacement or repair.

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(2\)

HOW TO CHOOSE A PROPER LOCATION FOR THE CEILING FAN

CAUTION

  • Use of unapproved remote control voids the warranty. Therefore do not control the operation of this fan from any controller that is not approved by our fan.
  • Do not use solid state controllers.

FAN INSTALLATION INSTRUCTIONS

WARNING

  • Make sure electricity is turned off at the main power box before commencing work. Turn off the power by removing fuse or turning off circuit breaker before installing the fan and replacing the lamps.
  • The lowest point on the fan blade must be at least 2.3 (7.5ff) metres from the floor.
  • Make sure that ceiling joists are strong enough and of adequate size to support the weight of the fan of about 35kg.

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(3\)

WOOD CEILING
Dismantle the mounting bracket from motor assembly, Position the mounting bracket in the desired location and fix it using the 4 screws and washers provided.

CONCRETE CEILING

Position the support in the desired location and mark the holes to be made. Remove the support and drill the concrete structure by making 2 © 8 mm holes. Remove dust and introduce the anchor studs supplied using a hammer (leave the threaded rod sticking out). Remove nuts and washers, replace the support and replace the washers and nuts. Tighten the nuts securely using a suitable wrench.

Then tighten the 4 screws.
Make sure that you tighten properly to prevent a fall.

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(6\)

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(7\)

Turn the housing counterclockwise until the protruding points of the housing lock in the notches of the mounting bracket.

Assemble the blades using the screws and washers provided. Caution, tighten the screws carefully to avoid damaging the blades. Make sure it is properly tightened to avoid excessive vibration problems during start-up. repeat this step for all blades.

Connect the LED connector of the ceiling fan to the one of the light kit, place the light kit on the motor flange then fix it using the 3 screws.

HUMHOLD-HDZYS-52-Inch-Low-Profile-Ceiling-Fan-With-Lights-FIG-
\(10\)

FAN OPERATION INSTRUCTIONS

  1. DON/OFF the fan
  2. ON/OFF the light
  3. Speed of the fan
  4. Direction of the fan (reverse switch)
  5. Timing control of the fan
  6. Nature wind mode
  7. Delay closing the fan
  8. Anti-stealing function
  9. Mute mode
  10. 1. 5V AAA battery X 2pcs
  11. indiested lamn

KINDLY REMINDERS:

  1. The learning code matching method is adopted between the remote control and the control board. Connect the power supply, long press the “OFF the fan” key for 3-5 seconds to match the learning code matching.
    After hearing a “bee” sound, it means that the matching code issuccessful.
    (PS: Turn off the code mode after 30 seconds)

  2. When the remote control cannot control the control board, check whether the battery supply side is in normal contact, or positive and negative electrodes, or check the battery power condition.

  3. When the remote control cannot control the control board, please check whether similar remote control products are working nearby, because the controlling products of the same frequency of the remote control will interfere with each other.

  4. The low battery voltage of the remote control will affect the sensitivity and signal receiving of the remote control (the indicator light will flash warning when the battery voltage is low).
    Please replace the battery with too low voltage in time. Take it out the battery from the transmitter handset when left unused for extended periods.

INFORMATION FOR LICENSED ELECTRICIAN AND FAN OWNERS
Please read fault finder before calling customer service centre.

  1. Fan Will Not Start

    • Check that mains circuit breakers are in the ON position.
    • Check that isolation wall switch is in the ON position.
    • Check that batteries in the remote handset (if any) are in good condition.
    • Carry out and complete remote transmitter and receiver pairing process.
    • Check that live, neutral, ground and light (if any) wires from isolation wallswitch, remote receiver (if any) through to fan are all wired correctly in accordance with wiring diagram.
    • Check that all wire connections at wall switch, wire connector and/ or terminal block are secured (not loosened).
  2. Fan Sounds Noisy

    • Fully tighten light fitting (version with light)
    • Re-tighten all screws on tan blades (do not over tighten)
    • Re-tighten all screws in the hanging bracket and covering plate
  3. Mechanical Noise

    • Let the fan run for about 8 hours for settling in period.
  4. Fan Turns But Does Not Move Much Air

    • The tan may be running in reverse (tor fans with reverse running option)
    • The distance from the ceiling to the fan blades is too small
    • The room may contain items which obstruct the air flow
    • The fan may be too small for the size of the room
  5. Fan Wobbles
    Check for wobble atter each step

    • Check that all blade brackets are tightened securely
    • Most wobble problems result from inconsistent blade level. To check blade level, measure the distance from each blade tip to the ceiling. If measurements are inconsistent, adjustments of brackets will be required.
    • Wobble problem could be also result from deviations in distance from blade to blade. To check blade separation, measure the distance from blade tip to blade tip. Should measurements vary, loosen screws connect- ing blades and brackets (one at a time) then shift the blade to proper position and re-tighten screws.

IMPORTANT FACTS
All electric motors, including fan motors make some noise and may feel hot to touch, this is not a fault. Ceiling fans tend to move during operation as they arenot generally rigid-mounted. Rigid mounted ceiling fans generate excessive vibration and stress on their mountings.
Movement of a couple of centimeters is quite normal and does not suggest the tan will tall down.
Please note – all ceiling fans are not the same, even in the same model some may move more or less that others.
Fan lights can rattle, if they are not supplied with the fan. They are not covered by warranty.

Fan Operation

A ceiling fan is an environmentally smart choice when it comes to cooling as well as helping to warm your room. You should see a reduction in both cooling and heating costs by regular use of your fans. Do not hesitate to use your fans inboth summer and winter months.
In summer fans should be set to spin in anti clockwise direction blowing down cool breeze.
In winter, fan should be set to spin in clockwise direction so that an upward airflow will push warm air off the ceiling and circulate it downwards into the living areas. In winter months use the fan on a lower speed than in summer.

Normal Wear And Tear
Threaded components working slightly loose, or blade carriers becoming slightly bent due to vigorous cleaning or bumping can cause extra wobble and noise.
This is not covered under warranty, but a little care and maintenance can reduce or prevent this problem.

Night Noises
This is the biggest cause of service calls, which are outside the manufacturer’s warranty. If a fan has a fault it will be noticeable at all times. Naturally when everything is quiet at night you will be more inclined to hear small noises, which may not be noticeable at other times. Even slight signals super imposed in your electricity supply for off peak hot water control may cause a change in the ran motor noise. This is normal.

Warranty

Dear Buyer,
Thank you for your order. To ensure that you can enjoy our warranty service. we kindly remind you to register for the warranty within one month of receiving your order.

Please contact us at sweetshawty@sina.com and provide a screen shot of your order number along with any additional remarks to activate the warranty. Our team will promptly activate the warranty service for your order. If you encounter any issues during the installation or use of our product. please do not hesitate to reach out to us at the email address above. Our dedicated after-sales staff will provide you with a satisfactory solution.
We are committed to delivering the best possible service to our customers Therefore, we value your feedback and comments on your experience with us. If you have a moment to spare please share your thoughts with us. Your input will help us to continue to improve and serve our customers better.
Thank you for choosing our product, and we look forward to serving you.
Best regards
DefinElegant

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals