Outline Drawing
MINIMUM UNIT CLEARANCE TABLE
| SERVICE CLEARANCE (RECOMMENDED)
SIDES| 6″
FRONT| 6″
BACK| 6″
INLET DUCT| 6″
OUTLET DUCT| 118″
NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE
MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE
PRODUCT DIMENSIONS
Air Handler Model| A| B| C| D| E| F| G| Flow Control| Gas Line Braze
E4AH5E36A1J30A| 47.01| 20.98| 19.25| 19.72| 2.98| 17.87| 16.30| TXV| 3/4”
All dimensions are in inches
NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS
Product Specifications
MODEL | E4AH5E36A1J30A |
---|---|
RATED VOLTS/PH/HZ | 208-230/1/60 |
RATINGS(a) | See O.D. Specifications |
INDOOR COIL — Type | 3ODWH )LQ |
Rows — F.P.I. | 4-17 |
Face Area (sq. ft.) | 3.70 |
Tube Size (in.) | 1/4” |
Refrigerant Control | TXV |
Drain Conn. Size (in.)(b) | 3/4” NPT |
DUCT CONNECTIONS | See Outline Drawing |
INDOOR FAN — Type | Centrifugal |
Diameter-Width (In.) | 12-1/4″-13″ |
No. Used | 1 |
Drive – No. Speeds | Direct – 5 |
CFM vs. in. w.g. | See Fan Performance Table |
No. Motors — H.P. | 1 – 1/2 |
Motor Speed R.P.M. | 1050 |
Volts/Ph/Hz | 208-230/1/60 |
F.L. Amps |
3.8 |
**FILTER** |
|
Filter Furnished? (c) | NO |
REFRIGERANT | R-410A |
Ref. Line Connections | Brazed |
Coupling or Conn. Size — in. Gas | 3/4” |
Coupling or Conn. Size — in.Liq. | 3/8” |
DIMENSIONS | H x W x D |
Crated (In.) | 21″x46-1/2″x21″ |
Uncrated | 23″x52″x24-1/2″ |
WEIGHT | |
Shipping (Lbs.) / Net (Lbs.) | 154/123 |
(a) These Air Handlers are A.H.R.I certified withvarious Split System Air
Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to theSplit System
Outdoor Unit Product Data Guidesfor performance data.
(b) 3/4” Male Plastic Pipe (Ref: ASTM 1785–76)(c) Remote filter required.
Minimum Airflow CFM
E4AH5E36A1J30A
Heater| Minimum Heat Speed Tap
| With Heat Pump
BAYHTR1605BRKA
BAYHTR1610BRKA BAYHTR1615BRKA| Tap 3
Heater Pressure Drop Table
Airflow CFM
| Number of Racks| | Heater Racks
---|---|---|---
1| 2| 3| Heater Model| No. of Racks
Air Pressure Drop — Inches W.G.| BAYHTR1605BRKA| 1
1800| 0.02| 0.04| 0.06| BAYHTR1610BRKA| 2
1700| 0.02| 0.04| 0.06| BAYHTR1615BRKA| 3
1600| 0.02| 0.04| 0.06| |
1500| 0.02| 0.04| 0.06| |
1300| 0.02| 0.04| 0.06| |
1200| 0.01| 0.04| 0.05| |
1100| 0.01| 0.03| 0.05| |
1000| 0.01| 0.03| 0.05| |
900| 0.01| 0.03| 0.04| |
800| 0.01| 0.03| 0.04| |
700| 0.01| 0.02| | |
600| 0.01| 0.02| | |
Performance and Electrical Data
See product data or air handler nameplate for approved combinations of air
handlers and heaters.
Table 1. Air Flow Performance
E4AH5E36A1J30A
EXTERNAL STATIC(in w.g)| AIRFLOW
Speed Taps: 208 – 230 VOLTS
| Tap 1
| Tap 2
| Tap 3
| Tap 4
| Tap 5
0.1
| 756
| 872
| 1084
| 1240
| 1412
0.2| 651| 796| 1035| 1192| 1366
0.3| 594| 716| 979| 1149| 1320
0.4| 525| 653| 896| 1077| 1274
0.5| 453| 598| 835| 1006| 1194
0.6| 355| 527| 777| 939| 1167
0.7| 270| 460| 724| 888| 1072
0.8| 210| 380| 670| 832| 1027
- Values are with dry coil, no filter, and no heaters.
- CFM Correction for dry coil = Reduce 3%
Table 2. Electrical Data
E4AH5E36A1J30A
Heater Model No.| No. of Circuits/ Phases| 230 Volt| 208 Volt
Capacity| Heater Amps perCircuit| Minimum Circuit Ampacity| Maximum Overload
Protection| Capacity| Heater Amps perCircuit| Minimum Circuit Ampacity|
Maximum Overload Protection
KW| BTUH| KW| BTUH
NoHeater| | | | 3.8| 5| 15| | | 3.8| 5| 15
BAYHTR1605BRKA| 1/1| 5| 17000| 20| 25| 30| 3.75| 12800| 18| 23| 25
BAYHTR1610BRKA| 1/1| 10| 34000| 40| 50| 60| 7.5| 25500| 36| 45| 50
BAYHTR 1615BRKA| 1/1| 5+ 15| 51000| 20+40| 25+50|
30+60| 3.75+7.5| 38500| 18+36| 23+45| 25+50
- = Motor Amps
Features and Benefits
- Galvanized metal cabinet with captured foil face insulation
- 2% or less air leakage
- R-4.2 Insulating Value
- Multi-Position UP, Horizontal Left /Right
- Copper-Aluminum Coils
- Electric Heaters with polarized plug connections (sold as accessory)
- R-410A Thermal Expansion Valve
- ECM Motor ( 2.0 – 5 Ton Models )
- Low Voltage Pigtail Connections
- Draw Through Design
- Vertical and Horizontal Drain pan
- Single Color
- Fused 24V Power
- 5 year warranty
- Optional extended warranty available
About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit : www.trane.com or www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
E4AH5E36A1J-SUB-1A-EN 04 Apr 2023
Supersedes (New)
www.ahridirectory.org
Unitary Small AC AHRI Standard 210/240
Certification applies only when the complete system is listed with AHRI.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>