Submittal E4HL5018A1000A Split System Heat Pump User Manual

June 12, 2024
Submittal

Submittal E4HL5018A1000A Split System Heat Pump

Product Information

The product is a Split System Heat Pump with the model number E4HL5018A1000A. The dimensions of the outdoor unit are as follows: A- 31.35 inches, B- 35.83 inches, C- 14.13 inches, D- 15.36 inches, E- 16.59 inches, F- 5.97 inches, G- 6.07 inches, H- 3.71 inches, I- 6.09 inches. The model has a sound power level of 58 dB(A) at 63Hz. It uses a rotary compressor and has one stage of heat. The outdoor fan has a diameter of 21-5/8 inches and is driven by a direct variable speed motor. The motor operates at 2700 RPM and requires 208/230 volts and 1.1 amps. The outdoor coil is a plate fin type with 1 row and 21 fins per inch. The refrigerant control is an electric expansion valve.

Product Usage Instructions

1. Installation: Follow the installation instructions provided in the user manual to properly install the Split System Heat Pump. Ensure that the unit is placed in a suitable location with properclearance for airflow and maintenance.

2. Power Connection: Connect the power supply to the outdoor unit using the specified voltage, phase, and frequency (208/230 volts, single phase, 60Hz). Use HACR circuit breakers or fuses for electrical protection.

3. Circuit Ampacity: Check the minimum circuit ampacity required for the unit based on the RLA (Rated Load Amps) value indicated on the unit nameplate and specification sheet. Ensure that the circuit ampacity meets or exceeds this value.

4. Compressor Start Components: The unit does not have anyfactory-installed start components. If required, install the  necessary start components as per the installation guidelines and local electrical codes.

5. Outdoor Fan: The outdoor fan is a propeller type with a diameter of 21-5/8 inches. It is driven by a direct variable speed motor. Adjust the motor speed as per the desired cooling requirements.

6. Outdoor Coil: The outdoor coil is a plate fin type with 1 row and 21 fins per inch. Ensure that the coil is clean and free from any debris or obstructions for efficient heat transfer.

7. Refrigerant Control: The unit uses an electric expansion valve as the refrigerant control. No adjustment is required for normal operation.

8. Maintenance: Regularly inspect and clean the unit to ensure optimal performance. Refer to the user manual for detailed maintenance instructions.

9. For more information and support, visit the manufacturer’s website at www.trane.com or www.americanstandardair.com.

Outline Drawing

Submittal-E4HL5018A1000A-Split-System-Heat-Pump-fig
1

Model A B C D E F G H I
E4HL5018A1000A 31.35 35.83 14.13 15.36 16.59 5.97 6.07 3.71 6.09

All dimensions are in inches

NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS

SOUND POWER LEVEL

Model| A-Weighted Sound

Power Level [dB(A)]

| Full Octave Sound Power [dB]
63Hz| 125Hz| 250Hz| 500Hz| 1000Hz| 2000Hz| 4000Hz| 8000Hz
E4HL5018A1000A| 58| 56| 48| 46| 44| 55| 50| 38| 29
Note: Rated in accordance with AHRI Standard 270–2015
For reference only.

Product Specifications

OUTDOOR UNIT (a) E4HL5018A1000A
POWER CONNS. — V/PH/HZ (b) 208/230/1/60
MIN. CIR. AMPACITY 21.5

MAX. OVERCURRENT

PROTECTION

| 35
COMPRESSOR| Rotary
NO. USED — NO. STAGES| 1-VARIABLE
VOLTS/PH/HZ| 208/230/1/60
R.L. AMPS (c)| 15.8
FACTORY INSTALLED|
START COMPONENTS (d)| NO
INSULATION/SOUND BLANKET| YES
COMPRESSOR HEAT| NO
OUTDOOR FAN| PROPELLER
DIA. (IN.) — NO. USED| 21-5/8″-1
TYPE DRIVE — NO. SPEEDS| DIRECT — VARIBLE
NO. MOTORS — HP| 1-1/10
CFM @ 0.0 IN. W.G. (e)| 2700
MOTOR SPEED R.P.M.| 850
VOLTS/PH/HZ| 208/230/1/60
F.L. AMPS| 1.1
OUTDOOR COIL — TYPE| PLATE FIN
ROWS — F.P.I.| 1-21
FACE AREA (SQ. FT.)| 8.18
TUBE SIZE (IN.)| 3/8″
REFRIGERANT CONTROL| ELEC. EXPANSION

VALVE

REFRIGERANT|
LBS. – R-410A (O.D. UNIT) (f)| 5 LBS, 1 OZ
FACTORY SUPPLIED| YES
LINE SIZE — IN. O.D. GAS| 3/4″
LINE SIZE — IN. O.D. LIQ.| 3/8″
CHARGING SPECIFICATIONS|
SUBCOOLING| 5°F
DIMENSIONS| H x W x D
CRATED (IN.)| 40-1/4″×32-7/8″×18-

7/8″

UNCRATED (IN.)| 35-3/4″×31-5/8″×14-

1/8″

WEIGHT|
Shipping| 161
Net (Lbs.)| 104

  • (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
  • (b) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
  • (c) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
  • (d) No means no start components.
  • (e) Standard Air — Dry Coil — Outdoor
  • (f) This value is approximate. For more precise value see unit nameplate.

Mechanical Specification Options

General
The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 60335-2-40. Exterior is designed for outdoor application.

Casing
Unit is painted with a glossy corrosion resistant finish on all panels. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. All panels are subjected to our 500 hour salt spray test.

Refrigerant Controls
Refrigeration system controls include condenser fan, compressor drive and low pressure switches.

Compressor
The compressor features external over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.

Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grilles and panels.

Low Ambient Cooling
As manufactured, this system has a cooling capacity to 5°F.

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com

The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals