Einhell GE-DP Series Dirty Water Pump Instructions
- June 4, 2024
- Einhell
Table of Contents
- Einhell GE-DP Series Dirty Water Pump
- Safety regulations
- Layout and items supplied
- Proper use
- Technical data
- Before starting the equipment
- Operation
- Replacing the power cable
- Cleaning, maintenance and ordering of spare parts
- Disposal and recycling
- Storage
- Troubleshooting guide
- Service information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Einhell GE-DP Series Dirty Water Pump
CAUTION
- This equipment can be used by children of 8 years and older and by people with limited physical, sensory or mental capacities or those with no experience and knowledge if they are supervised or have received instruction in how to use the equipment safely and understand the dangers which result from such use. Children are not allowed to play with the equipment. Unless supervised, children are not allowed to clean the equipment and carry out user-level maintenance work.
- If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained personnel to avoid danger.
Danger!
When using the equipment, a few safety precautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the in-formation is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.
Safety regulations
Danger!
- Read all safety regulations and instructions. Any errors made in following the safety regula-tions and instructions may result in an electric shock, fi re and/or serious injury.
- Keep all safety regulations and instructions in a safe place for future use.
Danger!
The pump must be powered via an earth-leakage circuit breaker (RCD) with a
rated fault current of no more than 30 mA (according to VDE 0100 Part 702
and 738).
- The equipment is not designed for use in swimming pools and paddling pools of any kind or other bodies of water in which people or animals may be present during operation. It is prohibited to operate the equipment if a person or animal is in the danger area. Ask your electrician!
- The electrical plug-in connections must be protected from wet conditions.
- If there is a risk of flooding, place the plug-in connections in an area which is safe from flooding.
- Strictly avoid pumping aggressive liquids and abrasive sub-stances.
- Protect the equipment from frost.
- Protect the equipment from dry running.
- Take suitable measures to keep the equipment out of the reach of children.
- There is a risk of the liquid becoming contaminated by escaping lubricant.
Layout and items supplied
Layout (Fig. 1/2)
- Universal hose connection
- Floating switch
- Screw for height adjustment
- Intake cage
- Handle
- Suspension eye
Items supplied
Please check that the article is complete as specified in the scope of
delivery. If parts are missing, please contact our service center or the sales
outlet where you made your purchase at the latest within 5 working days after
purchasing the product and upon presentation of a valid bill of purchase.
Also, refer to the warranty table in the service information at the end of the
operating instructions.
-
Open the packaging and take out the equipment with care.
-
Remove the packaging material and any packaging and/or transportation braces (if available).
-
Check to see if all items are supplied.
-
Inspect the equipment and accessories for transport damage.
-
If possible, please keep the packaging until the end of the guarantee period.
Danger!
The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suffocating! -
Dirty water pump
-
Universal hose connection
-
Original operating instructions
Proper use
- The equipment you have purchased is designed to pump water with a maximum temperature of 35 °C. This equipment must never be used for other liquids, especially not for engine fuels, cleaning agents and other chemically-based products!
- Before you use the pump, clarify any possible special conditions which need to be fulfilled for the installation!
- For example, additional safety measures may be needed if damage to property could result from a power failure, soiling or a defective gasket. Examples of such safety measures:
- Pumps running in parallel on a separately protected power circuit, moisture sensors for switching off the pumps, and similar safety arrangements. Be sure to consult a professional plumber if you have any doubt.
- The equipment can be used wherever you want to move water, e.g. in the house, in the garden, and for many other applications. It must not be used to operate swimming pools!
- If you want to use the equipment in bodies of water with a natural, muddy bottom, place the equipment in a slightly elevated position, e.g. on bricks.
- The equipment is not designed for continuous operation, e.g. as a circulating pump in a pond. In this case the equipment’s anticipated life will be greatly shortened because the equipment was not designed for continuous loading.
- The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
- Please note that our equipment has not been de-signed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.
- The water may be contaminated by escaping lubricating oil/lubricant.
Technical data
- GE-DP 7330 LL ECO
- Mains connection: 230 V ~ 50 Hz
- Power consumption: 730 W
- Max. pumping rate: 16500 l/h
- Max. delivery head: 8.5 m
- Max. immersion depth: 7 m
- Max. water temperature: 35°C
- Hose connection: approx. 47.8 mm (G 1½ ) AG
- Max. size of foreign bodies: Ø 30 mm
- Switching point height: ON: max. approx. 60 cm
- Switching point height: OFF: min. approx. 5 cm
- Suction height: min. 1 mm
- Protection: IPX8
- GE-DP 5220 LL ECO
- Mains connection: 230 V ~ 50 Hz
- Power consumption: 520 W
- Max. pumping rate: 13500 l/h
- Max. delivery head: 7.5 m
- Max. immersion depth: 7 m
- Max. water temperature: 35°C
- Hose connection: approx. 47.8 mm (G 1½ ) AG
- Max. size of foreign bodies: Ø 20 mm
- Switching point height: ON :max. approx. 60 cm
- Switching point height: OFF: min. approx. 5 cm
- Suction height: min. 1 mm
- Protection: IPX8
Before starting the equipment
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
Installation
- The equipment can be installed either:
- Stationary with a rigid pipe line or
- Stationary with a flexible hose line
- The equipment must be fastened to the suspension eyelet with a rope (Fig. 2/Item 6).
- The maximum pumping rate is possible only with the largest possible line diameter; if smaller hoses or pipes are connected, the pumping rate will be reduced. If the universal hose connection (Fig. 1/ Item 1) is used, it should be shortened (as shown in Fig. 9) to the connection actually used in order not to reduce the pumping rate unnecessarily. Flexible hoses must be fastened to the universal hose connection with a hose clip (not included in the scope of supply).
Note!
When installing, never hang the equipment by the discharge line or by the
power cable. The equipment must be hung up by the provided carry handle or
suspension eyelet, or it must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft always must be free of
sludge and other accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the equipment from
starting. It is necessary therefore to check the equipment regularly (carry
out trial start-ups).
The pump shaft should measure at least 50 x 50 x 50 cm so that the floating
switch can move freely.
Mains connection
Danger!
The equipment you have purchased comes with an earthing-pin plug. The
equipment is designed for connection to a socket outlet with earthing contact
for 230 V ~ 50 Hz. Make sure that the socket-outlet is sufficiently fused (at
least 6 A) and in good working order. Insert the power plug in the socket-
outlet and the equipment is ready for operation.
Operation
You can put the equipment into operation after you have thoroughly read the installation and operating instructions. Pay attention to the following points:
- Make sure that the equipment is set up securely.
- Check that the discharge line is fitted correctly.
- Make sure that the electrical connection is 230 V ~ 50 Hz.
- Check that the electrical socket-outlet is in good working order.
- Make sure that no moisture or water can ever reach the power connection.
- Make sure that the equipment does not run dry.
- To switch off the equipment, pull the power plug out of the socket outlet.
Setting the On/Off switching point:
The ON/OFF switching point can be infinitely adjusted with the height
adjustment facility. For this purpose you must first slacken the screw (Fig.
3, Item 3). The switching differential can be infinitely adjusted by extending
or shortening the fl oat cable (Fig. 3).
- The floating switch must be fitted so that the switching point height: ON and the switch point height: OFF can be reached easily and with little force. Check this by placing the equipment in a container filled with water and carefully raising and lowering the floating switch with your hand. You can then see whether the equipment switches on and off.
- Make sure that the distance between the floating switch head and the cable holder is not too smaller than 10 cm (Fig. 3). If the distance is too small, there is no guarantee that the equipment will work correctly.
- When adjusting the floating switch, make sure that the floating switch does not touch the bottom before the equipment is switched off. Important! Risk of dry running.
Manual operation:
Mount the floating switch as illustrated in Fig. 1.
The equipment will then run continuously. To prevent dry running, this
operating mode is allowed only under supervision. The equipment must be
switched off (pull out the power plug) as soon as no more water is emitted
from the discharge line.
-
Dirty water mode (Fig. 4/5):
- Turn the equipment counter-clockwise up as far as the stop (Fig. 4/5).
-
Shallow suction mode (Fig. 5):
- Turn the equipment clockwise down as far as the stop (Fig. 5).
- In shallow suction mode, water can be sucked up down to a level of 1 mm.
- Only clean water can be sucked up in shallow suction mode.
Please note:
For the equipment to suck up water in shallow suction mode there must be a
minimum depth of 10 mm of water.
Replacing the power cable
Danger!
If the power cable for this equipment is damaged, it must be replaced by the
manufacturer or its after-sales service or similarly trained personnel to
avoid danger.
Cleaning, maintenance and ordering of spare parts
Danger!
Always pull out the mains power plug before starting any cleaning work.
Cleaning
- Keep all safety devices, air vents and the motor housing free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.
- We recommend that you clean the device immediately each time you have finished using it.
- Clean the equipment regularly with a moist cloth and some soft soap. Do not use cleaning agents or solvents; these could attack the plastic parts of the equipment. Ensure that no water can seep into the device. The ingress of water into an electric tool increases the risk of an electric shock.
Cleaning the intake cage and pump housing (Fig. 5/6/7/8):
- Screw out the three screws (Fig. 6/Item B) counter-clockwise.
- Turn the equipment up as far as the stop (Fig. 5). Note the position of the lug (Fig. 5/Item A) and remove the intake cage (Fig.7/Item 4).
- Clean the intake cage (Fig. 7/Item 4) and the pump impeller housing (Fig.7/Item C) with clean water.
- Assemble in reverse order.
- When assembled, the lug must be in the correct position (Fig. 8/Item A).
Maintenance
There are no parts inside the equipment which require additional maintenance.
Ordering replacement parts:
Please quote the following data when ordering replacement parts:
- Type of machine
- Article number of the machine
- Identification number of the machine
- Replacement part number of the part required
For our latest prices and information please go to www.Einhell- Service.com
Disposal and recycling
The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offices.
Storage
Store the equipment and accessories in a dark and dry place at above freezing temperature. The ideal storage temperature is between 5 and 30 °C. Store the electric tool in its original packaging.
Troubleshooting guide
Faults | Cause | Remedy |
---|---|---|
The equipment does not start | – Power supply not connected |
– Floating switch does trigger
| – Check power supply
– Raise position of floating switch
The equipment does not pump| – Intake sieve clogged
– Discharge hose kinked
| – Clean intake sieve with water jet
– Unkink the hose
The equipment does not cut out| – Floating switch cannot sink| – Place
equipment correctly on shaft bottom
Insufficient pumping rate| – Intake sieve clogged
– Performance reduced due to heavi- ly contaminated and abrasive water impurities
| – Clean intake sieve
– Clean equipment and replace wear parts
The equipment swit- ches off after briefly running| – Motor circuit- breaker switches the equipment off due to excessive wa- ter contamination
– Water temperature too high; motor circuit-breaker switches the equip- ment off
| – Unplug power plug and clean equipment and shaft
– Ensure that maximum permissible water temperature (35 °C) is not exceeded
For EU countries only
- Never place any electric power tools in your household refuse.
- To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and its implementation in national laws, old electric power tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
- Recycling alternative to the return request:
- As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment. The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations. This does not apply to any accessories or aids without electrical components supplied with the old equipment.
- The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the Einhell Germany AG.
Subject to technical changes
Service information
- We have competent service partners in all countries named on the guarantee certifi cate whose contact details can also be found on the guarantee certificate. These partners will help you with all service re-quests such as repairs, spare and wearing part orders or the purchase of consumables.
- Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables.
Category| Example
---|---
Wear parts| Impeller
Consumables|
Missing parts|
Not necessarily included in the scope of delivery!
In the effect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. Please ensure that you provide a precise description of the problem and answer the following questions in all cases:
- Did the equipment work at all or was it defective from the beginning?
- Did you notice anything (symptom or defect) prior to the failure?
- What malfunction does the equipment have in your opinion (main symptom)?Describe this malfunction.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>