Model No. SDZ1-30P

Safety Warning

For your safety, please read the following contents carefully before using this dehumidifier:

Requirements:

  • Install this humidifier in smooth place to reduce vibration and noise.
  • Do not place this dehumidifier in water or other liquids.
  • In order to prevent accidents, please do not use this dehumidifier if wires or other connections are damaged.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.cleaning and user maintenance shall not be made by children without supervision.
  • When stop, reset or clean this dehumidifier, please cut off the power.
  • Please use at the specified voltage.
  • This dehumidifier can only be used indoor, please do not use for other purposes.
  • Please do not place heavy objects on this dehumidifier.
  • Please empty water tank to prevent overflow and spill before restarting this dehumidifier.
  • Please do not incline in case that the spilled water damages this dehumidifier.
  • Please do not place waste rods and hard objects into the dehumidifier in case that error and damage occur.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • When this dehumidifier is not used for long time, please unplug the electric cord.
  • Power supply of the Dehumidifier shall comply with the safety regulations where it is used and ensure reliable grounding.

Prohibition:

▲ Please do not place this dehumidifier close to heating devices (flame or heaters, etc.).

▲ Please do not turn on or turn off this dehumidifier by plugging in or pulling out the plug.

▲ Do not use insecticide spray or other flammable substances in the vicinity of this dehumidifier.

▲ Do not scratch appearance of this dehumidifier with sharp matters.

▲ Do not splash oil or water into this dehumidifier.

▲ Do not clean this dehumidifier with water, please wipe it with subhumid soft cloth.

▲ Do not wipe this dehumidifier with chemical solvents such as benzene, gasoline and alcohol, etc. If this dehumidifier is indeed dirty, please wipe with neutral detergent.

▲ Please do not incline this dehumidifier over 45°or place this dehumidifier upside down.

Frequent enquiries

Q: Why is less water stored in water tank of the dehumidifier in winter?

  • In winter temperature is low and air is dry. In comparison with summer, the dehumidification ability of the dehumidifier decreases remarkably, this is not a fault.

Q: Why the dehumidifier running suddenly?

  • This dehumidifier may be full of water or water tank is not installed properly, drain the water in water tank, or re-install water tank in correct way.
  • At the moment the dehumidifier may be in the “dehumidification mode”, the ambient temperature is lower or higher (dehumidification cannot be performed )when the ambient temperature is <41℉ or >90℉).
    The ambient temperature for operation of the dehumidifier is 41 – 90 ℉, and the relative humidity is 30%-80%. The optimal temperature for use is 61-90℉;

Q: Why is hot air blown out from air supply outlet?

  • This dehumidifier extracts the air in the room, and the dehumidification unit cools the air, the temperature decreases below the condensation point, the air condenses into water drops, which falls into water tank finally, and the dehumidified air is heated by the temperature returning unit. This can reduce energy consumption and also accelerate dehumidification, therefore, hot air is blown out, and this not a fault.

Installation

  • Please drain the water from water tank before running.
  • During running please do not open doors and windows as much as possible since this can save energy resources.
  • When the dehumidifier is installed, a certain space must be reserved around this dehumidifier, the minimum distance above is 19.7in, and the minimum distance in front/rear and left/right is 7.9in as required, as shown in figure below.
  • When big noise is found during operation of this dehumidifier: It is recommended inserting pads or damping rubber sheets, etc. below this dehumidifier, this can reduce vibration and noise, and can also reduce sinking of wood floor or carpet.

Installation

Components

Front side

Front side

Back side

Timer

24h timer setup, press this key to set on/off time of the dehumidifier, and the setting range is 1-24h. If you cancel timer setup, press twice continuously after confirmation of setting time.

Dry key in dehumidifier

Press this key start drying procedure in the dehumidifier

Air speed

In AUTO or CONTINUOUS mode air speed, HIGH and LOW can be circularly selected.

LED Display

LED Display

In AUTO, CONTINUOUS AND DRYING modes, etc., this figure displays room humidity. When humidity is set in AUTO mode, this figure shows the set humidity; and displays the set time in timer state, % represents percentage of humidity

Humidity setting

Once this key is pressed, the humidity is displayed circularly in the range of 30%-35%-40%-45%-50%-55%-60%-65%-70%-75%-80%, and the humidity setting is only valid in AUTO mode.

Mode

During startup or timer startup press this key to select AUTO, CONTINUOUS and DRYING modes, etc., and the indicator lamp corresponding to the selected mode is on.

Press this button 3s , the child lock function starts. Re-press 3s, cancel the function.

On/off key Press this key to turn on or turn off the dehumidifier.

Operating methods

Description of functions

Setting of timer off

  • When the dehumidifier is running, press the [Timer key] to adjust time from 1h to 24h, pressing the key once to increase the setting time by 1h, after the setting time exceeds 24h, the figure returns to 1 to start cycle. The Timer key can also be pressed all the time, the time increases and changes circularly, when the set time expires, the dehumidifier turns off automatically. After the setting is completed, if the Timer key does not act at all within 5s, the set time is confirmed. In timer off state the key lamp on the [Timer key] is normally on.

Setting of timer on

  • When the dehumidifier is in standby state, the method for adjustment of setting time by the [Timer key] is the same as timer off. After the setting is completed, if the Timer key does not act at all within 5s, the set time is confirmed. In timer on state the key lamp on the [Timer key] is normally on, and the set time is displayed on controlpanel.

AUTO mode

  • Select AUTO dehumidification, if the room humidity is high than the set humidity or is between +5% or -5% of the set humidity , the compressor will starts and the fan will run at the set speed. If the room humidity is lower than the set humidity by -5%, then the compressor will stop but the fan will run at the set speed. The default set humidity value is 50%.

CONTINUOUS mode

  • Select CONTINUOUS dehumidification, no matter how the relative humidity in the room is, the compressor starts, the fan runs at high speed in default, and the air speed can be regulated via the air speedkey.

DRYING function in dehumidifier

  • Press the Drying key in dehumidifier to start drying in the duhumidifier to prevent inner unit mildew .

Drainage

1. Use of water tank

When the water tank is full of water, the full water icon on LED flashes (the compressor, fan and negative ion will stop running), the BUZZER sounds for 10 times to remind the user till water is drained.

  • Place both hands respectively at the side of the back cover side of the depression, gently remove the water tank and open the tank cover on the right side of the body, then pour the water from the gap between water tank and the cover.

  • Close the tank cover, and rotating water tank handle down,then put the water tank gently and put it back in the right place to restart dehumidifier.

Attention: when the water tank is full of water, please empty it. Before putting the water tank into the dehumidifier, please confirm whether the floater rotates flexibly or not, and then push it in position with both hands.

2. Continuous drainage

If you do not want to drain water in the water tank frequently, you can connect a drainage pipe on the back of this dehumidifier to drain water. Two kind of pipe is optional . One is inner diameter 9mm ,which provided by manufacturer. Another is standard screw thread garden drain pipe with outer diameter of 1 1/16 inches and the pitch of 11.5TPI

  1. Find out the water outlet location on the back of the unit:screw off the water cap(counterclockwise),then insert the 9.0mm water hose to the drain,the operation is completed,as shown in figure 1.

  2. Find out the water outlet location on the back of the unit:screw off the water cap(counterclockwise),then connect garden drain pipe,the operation is completed,as shown in figure 2.

Continuous drainage Figure 3

Attention: the level height of externally connected water pipe shall not be higher than the water outlet, and the water pipe at rear-end shall transit smoothly, otherwise, the leakage risk exists since drainage is not smooth.

Maintenance

Precautions:

  • Please disconnect power supply before maintenance or repair to prevent electric shock.

  • If the dehumidifier is not used for long time, please disconnect power supply.

  • Please do not clean the dehumidifier body with chemical solvents such as alcohol, gasoline and benzene, etc.。

  • Please clean the water tank and its cover with soft cloth dipped in cold or warm water at regular time to prevent mould inside the dehumidifier.

  • Wipe the surface of the dehumidifier slightly with wet cloth, and do not use detergent or abrasive in case the plastic surface is damaged.

  • Clean the washable PP strainer at lease once per two weeks simply with cold or warm water, do not use chemical solvents or hot water.

Troubleshooting

If the following problems occur to the dehumidifier, the following solutions can be adopted.

Troubleshooting Table 1

Troubleshooting Table 2

Technical Parameters

Technical Parameters

All data are for reference only, and are modified for improvement of product functions or technology without notice.

Meaning of crossed –out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available.

If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge

TO OBTAIN WARRANTY SERVICE:

Sales support:service@shinco.net

Working Time : From 8:30AM to 5:00PM Monday through Friday Standard (Eastern) Time

WARRANTY PERIOD:

Labor: 1 Year from the Date of Purchase.

Parts: 1 Year from the Date of Purchase.

YOAU Electric Co., Ltd reserve rights to upgrade products without user notice.