HIKVISION Configure Automation Device in AX PRO Wireless Control Panel Instructions
- June 6, 2024
- Hikvision
Table of Contents
HIKVISION Configure Automation Device in AX PRO Wireless Control Panel
Instructions
Preparation
- DS-PWA Series AX PRO Wireless Security Control Panel
- Automation Device(Relay Module) DS-PM1-O1L-WE and Wireless Keyfob
- IE Browser and Hik-Connect App
How to Configure Automation Device in AX PRO Wireless Control Panel
Use Event Type to Control Automation Device
-
Add the Automation Device to AX PRO at first
-
Login AX PRO, select Device—Automation—Configuration
-
Configure Original Status—Normal Open or Normal Close
-
Configure Tamper Input: If third part device Tamper signal is connected, you can enable this function. Need select Tamper input Status(NO or NC)
-
Configure Event linkage
Note: AND Mode means only all zone triggered, then relay will output
Schedule: Configured time period, the Automation Device will be normal
open or normal close
Disarm: Disarm Event will link the Automation Device open or close
Silence Alarm: Silence Alarm Event will link the Automation Device open or close
Fault: System Fault Event will link the Automation Device open or close
Manual: You can manually control the Automation Device open or close in
Hik connect
Use Keyfob to control Automation Device
-
Add the Automation Device and wireless keyfob to AX PRO at first
-
Configure Keyfob Button linkage to Automation Control, and select the relay number.
-
Configure Automation Control Device Event Type—Manual, select Activation Mode and Pulse Duration.
Activation Mode
Pulse: Relay output for a short time period and then stop
Latch: Relay output continuously
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>