Shinco Portable Air Conditioner User Manual

June 7, 2024
Shinco

Shinco LOGO SPS5-14H
Portable Air Conditioner
User’s Manual

Shinco Portable Air Conditioner

Thanks for choosing this high-quality portable air conditioner.
Please read the Manual carefully before operation. In case of any problem, please contact professional maintenance personnel in time.

USER KNOWLEDGE

The meaning of this user manual is shown below.

| Please prohibit such operations for your health and safety with your family.
---|---
| For the sake of the health and safety of your family, you must do the following.

MATTERS NEEDING ATTENTION

This machine is for household use only.

Shinco Portable Air Conditioner -householdThis machine is for indoor use only Please place it in dry environment.

Shinco Portable Air Conditioner - environment.Do not stack items around the machine so as not to impede the air exchange.

Shinco Portable Air Conditioner -exchange

Do not place heavy objects on the machine to avoid damage to the machine.

Shinco Portable Air Conditioner -damageDo not operate the unit with wet hands or in a humid environment.

Shinco Portable Air Conditioner - outletPlease wipe the machine with a soft cloth. Do not use wax, thinner or irritant detergent.

Shinco Portable Air Conditioner - irritant detergent.Please clean the filter regularly and recommend cleaning once every two weeks.

Shinco Portable Air Conditioner - two weeks.

For your health, please don not drink condensed water discharged from the machine.

Shinco Portable Air Conditioner -discharged

Please unplug the power supply if the machine is not used for a long time.

Shinco Portable Air Conditioner - unplug the powerNonprofessionals should not disassemble or repair the machine without authorization.

Shinco Portable Air Conditioner - disassemble

IMPORTANT SAFETY TIPS

Please not use a damaged power cord or power cord plug, do not insert power cord into the loose socket.

Shinco Portable Air Conditioner - damaged

Do not damage or use damaged or unknown type of power cord. Please ensure that the voltage used meets the requirements before use.

Shinco Portable Air Conditioner - requirements

Do not modify or extend the power cord.

Shinco Portable Air Conditioner - extend the power

It is recommended to use grounding receptacles when running this unit.

Shinco Portable Air Conditioner - receptacles

Do not plug or unplug the power cord with wet hands, this operation has the risk of causing electric shock.

Shinco Portable Air Conditioner - electric shock

When pulling the power cord, please pinch the plug and do not pull the power cord.

Shinco Portable Air Conditioner - pulling the power
cord

Do not control the opening and closing state of the machine by plugging the power plug.

Shinco Portable Air Conditioner - control the openingPlease turn off the machine before you pulling the plug.

Shinco Portable Air Conditioner - turn off the machine

Do not share a power outlet with multiple high-power electrical appliances.

Shinco Portable Air Conditioner - electrical

Please keep the machine away from the heat source and avoid direct sunlight.

Shinco Portable Air Conditioner - avoid direct

If the machine makes a strong noise, smell or smoke, please turn off the machine immediately and pull the plug to check the cause.

Shinco Portable Air Conditioner - check the causeDo not press heavy objects on the power cord, so as to prevent the power cord from being crushed and cause electric shock.

Shinco Portable Air Conditioner - electric shock

Don’t insert your fingers or any hard object to wind guide bar of the air outlet.

Shinco Portable Air Conditioner - humid environment

Do not let water enter the electrical part of the machine.

If water enters the machine, shut it down immediately and pull out the plug, then contact the professional maintenance personnel for repair.

Shinco Portable Air Conditioner - repair

If you need to wipe, clean, move the machine or replace the machine parts, please turn off the machine and unplug the power plug first.

Shinco Portable Air Conditioner - plug first

When the gas leak occurs, please open the windows first, ensure the air circulation, then run the machine.

Shinco Portable Air Conditioner - run the machine

The appliance user must be eight years of age. Weak people, people with weak sensory abilities or low psychological quality must be supervised and used when they understand the correct use methods and harmfulness. Children are prohibited from playing. Children must be cleaned and maintained under supervision.

Shinco Portable Air Conditioner - supervision

SPECIAL WARNING

Place the A/C on even ground and install it vertically, so as to ensure normal operation of the compressor.

Shinco Portable Air Conditioner - compressor

The A/C should be at least 19.7in. away from surrounding objects. Keep air inlet and outlet smooth.

Shinco Portable Air Conditioner - smoothDon’t use the A/C beside gasoline or any other inflammable liquid.

Shinco Portable Air Conditioner - inflammable liquid

Don’t use spraying agents and other solvent or flammable substances near the A/C; otherwise, its plastic may deform and  electric parts may be damaged.

Shinco Portable Air Conditioner - may be damaged

PRODUCT INTRODUCTION

MAIN PARTS COMPONENTS

Shinco Portable Air Conditioner- MAIN PARTS 1| Shinco Portable Air Conditioner- MAIN PARTS| Shinco Portable Air Conditioner- assembly
---|---|---

1.Handle
2.Air inlet (Down)
3.Control Panel
4. Air outlet louver
5. Castor
6. Remote controller
7. Air outlet(Up)| 8.Hot air outlet
9.Drainage nozzle
10. Air outlet grille
11. Exhaust duct assembly
12. Window sealing plate assembly
---|---

CONTROL PANEL AND REMOTE CONTROLLER

Shinco Portable Air Conditioner- CONTROL PANEL

  1. Power key
    Press the key to turn ON/OFF the A/C.

  2. Speed key
    Press the key to choose high/middle/low speed.

  3. Temperature/ time adjusting key
    Press the key at cooling mode or heating mode to increase/reduce the set temperature; press it at timing mode to adjust timing ON/OFF time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature.

  4. Mode key
    Press the key to choose cooling, heat, fan, dry.

  5. Timer key
    Press the key at standby mode to set ON time.
    Press this key at ON mode to set OFF time.

  6. Temperature/ time display window
    This window displays the adjusted temperature and time.

  7. Switch key
    Press the key to switch ℃ and ℉.

  8. Swing key
    Press this button or press the speed key and timing key simultaneously to turn on / off the swinging function.

Shinco Portable Air Conditioner- remote

PRODUCT OPERATION

PLANCEMENT AND INSTALLATION

Placement

Place the machine on the horizontal floor near the window.
In order to maintain good air circulation and make the machine get the best performance, there should be at least 19.7in. space around it.
.Shinco Portable Air Conditioner- Placement

Installation

Shinco Portable Air Conditioner- Exhaust duct assembly

Step 1:

  1. Measure window size;
  2. Adjust the length of the window sealing plate to make it fit with the size of the window.
  3. When the length of the window seal plate is fixed, the length of the sealing plate is fixed by the hand pull button.

Shinco Portable Air Conditioner-Step 1

Step 2:
Install the fixed window seal on the window.

Shinco Portable Air Conditioner- Step 2

Step 3:
Swirl the exhaust pipe assembly (exhaust fitting end) into the rear panel outlet (counterclockwise).

Shinco Portable Air Conditioner- run properly

Step 4:
Clip the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up.

Shinco Portable Air Conditioner- Step 4

Overall effect diagram after assembly

Incorrect installation

  • It’s important to keep the exhaust duct smooth. Incorrect installation will affect the work of the A/C.
  • Prevent the exhaust duct from sharp bending.
  • Ensure air can flow smoothly in the duct.

Shinco Portable Air Conditioner- flow smoothly

Warning
The exhaust duct is designed especially for this model. Don’t replace or lengthen it; otherwise, it will result in failure.
Notice:
Max. developed length of the exhaust duct is 59in. It’s better to shorten it while use and keep it horizontal while installation.

Shinco Portable Air Conditioner- REMOTE CONTROLLER

REMOTE CONTROLLER
Please install the battery correctly before using the remote control.
The specific steps are as follows:

  1. Slide the battery cover on the back of the remote control.
  2. Insert 2*AAA(DC1.5V) new batteries and ensure that batteries, and ensure that the battery electrodes are installed correctly when inserted.
  3. Fit the battery cover in place.

Notice:

  1. The remote controller can only use AAA(DC1.5V) batteries.
    Do not use rechargeable batteries or other types of batteries.

  2. Replace two batteries when replacing batteries. Do not mix old and new batteries.

  3. If the air conditioner is not used for a long time, please remove the battery in the remote control.

Warning:

  1. Do not use batteries if there is any leakage.
  2. Chemicals in batteries may cause burns or other health hazards. If the liquid flows to the skin or clothes carelessly, please wash them with clean water immediately; if you eat it carelessly, rinse your mouth with clear water immediately, and then go to the hospital for further examination.

OPERATION METHOD

Cool mode

  • When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
  • Press the Up/Down key to adjust the setting temperature (60°F ~ 86°F ).
  • Press the Speed key to choose High/Mid/Low speed.

Fan mode

  • When pressing mode key or choosing Fan mode by pressing the remote controller,
    the wind indicator lamp lights up.

  • Press the Speed key to choose High/Mid/Low speed.

  • Temperature can’t be set.

Dry mode

  • Shinco Portable Air Conditioner- Dry mode When pressing the mode key or choosing dry mode by pressing the remote controller, the dehumidification indicator lamp lights up.
  • Take off the water plug of the desiccant nozzle as shown on the right, insert the water guide pipe, and put the other end of the water guide pipe into the water container or drainage channel.
  • When entering the dry mode, the compressor is started if the room temperature is greater than 63 F Thereafter the compressor is controlled according to the following rules: when the room temperature is less than 59 F, the compressor is turned off; when the room temperature is raised to more than 59 F, the compressor is restarted (the compressor restart must satisfy the three-minute delay protection function).
  • In dry mode, the fan is defaulted to run at low speed, and wind speed can’t be adjusted ·
  • Temperature can’t be set.
    Use hint: when the dry function is used, the exhaust pipe assembly should be removed, otherwise, it will cause that dehumidification effect is not obvious and “FL” full of alarm display appears.

Heating mode

  • When the A/C enters heating mode automatically or heating mode is selected after power ON, the cooling indicator lamp lights up.
  • Press Up/Down key to adjust the setting temperature(60°F ~ 86°F ).
  • Press Speed key to choose High/Mid/Low speed.

Timer mode

  • In standby state, press the Timer key to set ON time. Press Up and Down keys to set  ON time (1~24H), and the timer indicator lamp lights up.
  • In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (1~24H), and the timer indicator lamp lights up.

CLEAN AND MAINTENANCE

DRAINAGE METHOD

This product is equipped with an automatic water vaporization system. The condenser is cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.
If the internal vessel is full of water, the display screen will display “FL”, and the compressor stops working automatically. At this point, the water needs to be discharged. The specific steps are as follows:

  • Unplug the power cord and take down the exhaust duct assembly.
  • Move the air conditioner to the right place.
  • Pull off the drain at the drain and drain the water inside the machine.
  • Re plug the water plug.
  • Reinstall the exhaust duct assembly and start the machine.

MAINTENANCE

Notice: In order to avoid electric shock, please turn off the A/C and unplug it before maintenance or repair.

CLEANING

  • Unplug before cleaning.
  • Wipe with soft semi-dry cloth. Don’t use chemical reagents, such as benzene, alcohol and gasoline etc; otherwise, the surface of the A/C and even the whole NC will be  damaged
  •  Prevent water from spattering in the NC.

Shinco Portable Air Conditioner- CLEANING

FILTER SCREEN
It is suggested to clean the filter every two weeks. If the indoor air quality is poor, the cleaning frequency should be improved appropriately. Because the filter screen is blocked by dust, it will reduce the efficiency of air conditioning. The specific cleaning steps are as follows:

  1. According to the direction of the chart, the lower intake grille is first taken out and the filter screen is removed.
  2. Clean the filter with clean or warm water (about 104 F) which has been added with neutral detergent, then put it in a cool place to dry.
  3. The filter screen cleaned and dried will be re-installed.
  4. Restart the machine and run properly.

Shinco Portable Air Conditioner- run properly

|
---|---
If the filter screen is not too dirty, just use  the vacuum cleaner to absorb the dust.| If the filter is dirty, clean the filter with clear water or warm water.  The temperature is about 104° F.

Notice:

  1. Do not use water with excessive temperature (suitable temperature is about 104° F) or irritant detergent (such as alcohol, gasoline, benzene, etc.) to clean the filter.
  2.  To avoid deformation of the filter, the cleaned filter should be kept away from the heat source and put in dry air to dry naturally.
  3. Do not run machines without filters.

SEASONAL CLEANING
If the A/C will not be used for a long time, Please follow these steps to maintain it:

  1. Pull out the water plug to drain.
  2. Run the A/C in fan mode for 2H till the inside is dry.
  3. Turn off the A/C and unplug.
  4. Wash the filter screen and reassemble it.
  5. Dismantle the exhaust duct and keep it properly.
  6. Take the battery from the remote control.
  7. Cover the A/C with a plastic bag and place it at a dry place.

If you haven’t used it for a long time, please pay attention to the following points when you use it again:

  1. Confirm whether water plugs and filters are installed.
  2. Check if the power cord is intact. If there is any damage, do not use it.
  3. Reinstall the remote battery.
  4. Reinstall the other components according to the installation instructions.

COMMON FAILURES AND DIAGNOSIS

INTELLIGENT ERROR DETECTION

Error-detecting code Multi-functional defection
E1 The error of the coil’s temperature sensor
E2 Error of indoor temperature sensor
E4 Anti-freezing protection: temperature of the coil is too low and the

whole  A/C is off. When the temperature excesses 46 ° F, the protection is released and the previous working state is recovered.

TROUBLE-SHOOTING

The following table lists the common faults and maintenance methods of this series of portable A/C. When the machine is in abnormal operation, the following table can be used for simple diagnosis and maintenance. If it still can not be solved,  lease contact professional maintenance personnel.

TROUBLE CAUSE SOLUTION
The NC doesn’t work No display Reset circuit breaker on AC cord
The display panel displays “F12 Restart the NC after power off and draining,

then it will become normal
Time OFF function is started| The NC can be restarted 3 minutes after being turned off
The NC

starts frequently

| Direct sunlight| Draw the curtain
Doors and windows keep open; there are lots of people or heat sources in the room| Close doors and windows, remove heat source
Filter screen is very dirty| Clean or replace it
Air inlet or air outlet is blocked| Remove the stem
Big noise of the NC| The NC is placed unevenly| Place it at even and firm ground, avoid shaking

MACHINE PARTS PARAMETERS

FUSE PARAMETERS

Specification: Φ5×20mm
Voltage: 250VAC
Current: 3.15A

MACHINE DIMENSIONS

Shinco Portable Air Conditioner- MACHINE DIMENSION

The above technical parameters are subject to change without notice.

Meaning of crossed-out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

TO OBTAIN WARRANTY SERVICE:
Toll number:833-3SHINCO
Working Time: From 8:30 AM to 5:00 PM Monday through Friday Standard (Eastern) Time
WARRANTY PERIOD:
Labor: 1 Year from the Date of Purchase.
Parts: 1 Year from the Date of Purchase.
YOU Electric Co., Ltd reserves rights to upgrade products without user notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals