INSTALLATION INSTRUCTIONS
• Please read these instructions completely before you begin.
IMPORTANT SAFETY INSTRUCTIONS
- Do not use this product near water; such as a bath tub, wash bowl, kitchen sink, laundry tub, swimming pool, or in a wet basement.
- Never push objects of any kind into this product through openings, as they may touch dangerous voltages. Never touch uninsulated telephone wires or terminals, unless the telephone line has been disconnected at the network interface.
- Never install communications wiring, or components, during a lightning storm.
- Equipment shall be installed in accordance with ANSI/NFPA 70, National Electrical Code (NEC), NFPA 72, CAN-ULC-S540, Canadian Electrical Code, and/or other applicable sections of ANSI/IEEE C2 & National Electrical Safety Code (NESC). Equipment intended for installation in information technology equipment (computer) rooms should be installed in accordance with NFPA 75, Standard for the Fire Protection of Information Technology Equipment.
- Power supplied to components must be provided by UL Listed Class 2 power limited power supply.
- All power limited and non-power limited wiring must be separated by a minimum of ¼” spacing.
- Installation shall be completed by a professional electrical contractor or low voltage technician.
- Maximum load carrying capacity of 30 lb.
Dimensions
Product Contents
Recommended Tools
Enclosure Physical Installation
Locate enclosure indoors in a low humidity, climate-controlled (0°C / 32°F –
49°C / 120°F) area within close proximity to power source. Remove cable
knockouts as needed. When required, 2” rubber grommets (AC1034) are available
to seal and protect openings. If mounting behind a TV, ensure box is
positioned to be concealed from view by the display.
RETROFIT Installation
Wall Prep
After the desired height is identified, use a stud finder to locate the
vertical stud locations. Place the cutting template against the wall surface
and trace the outline. Use a drywall saw to cut the box outline.
Trim Ring Installation
Use the included four (4) screws to affix the trim ring to the corresponding holes located in the enclosure frame.
CAUTION: DO NOT overtighten the screws.
Enclosure Installation
Insert the enclosure into the wall opening and utilize a Philips head screwdriver to engage the four (4) drywall clips in all corners. If near wall studs, you can also utilize drywall screws to secure box from the inside. Once installed in the wall – install the two (2) side screws to secure sides of the trim to the enclosure.
NEW CONSTRUCTION Installation
Surface Mount
Mount to a plywood backboard using the pre-drilled mounting holes on the rear
of the enclosure. The use of a level is recommended for correct installation
of the enclosure.
Flush Mount
The Enclosure is designed to fit between a minimum 2×4 studded wall at 16”on-
center (OC). If wall studs are greater than 16” on-center (OC) refer to
Retrofit Installation. Position Enclosure between wall studs at appropriate
depth (refer to drywall depth guide on enclosure ) and utilize four (4)
drywall screws to secure to wall studs.
Trim Ring Installation
After drywall is installed, use the included six (6) or four (4) screws to
affix the trim ring to the corresponding holes located in the enclosure frame.
Power Installation
Running Power to the Installation
Remove desired outlet knockout. Install a single-gang metal outlet box.
Connect 15 amp, 120 volt power receptacle to power cable with approved wiring
method to local codes.
NOTE: Legrand offers both non-surge protected (P/N F7526) and surge
protected (364569-02-V1) outlet kits. Only install standard size wall plates
as oversized plates will not fit.
Equipment Mounting Inside Enclosure
5IN Elevated Mounting Bracket [OPTIONAL]
The removable component mounting bracket allows the organization of devices
before or after installation. If desired the bracket includes four (4)
plunger/grommets to secure directly to the back wall of the enclosure –
Vertical or Horizontal.
Built-in Lacing Tabs
The back wall has assorted lacing tabs for securing large equipment directly
to the enclosure. The lacing tabs have a protective cover that can be removed
by utilizing a screwdriver and pushing the protective cover into the opening
to provide an unobstructed guide for hook and loop strapping.
Cover Installation
Install the Cover
To attach the cover, position cables exiting the enclosure towards the pass-
through opening and slide bottom tabs into receiving channels of the trim
ring. Push the sides of the cover into the locking side channels for a flush
finish. The 17” model has two covers for easy access to contents, even when
the enclosure is partially obstructed.
Thank you for choosing SANUS!