GeoVision GV-R1254 Access Reader User Manual

June 15, 2024
GeoVision

GV-R1254 Access Reader

Product Information

Specifications

  • Model: PWQGV-R1254 GV-R1254 V200620
  • FCC ID: PWQGV-R1254

Product Features

  • Slim design for easy installation
  • Master Card for adding/deleting tags
  • Set up parameters and user tags by external WG Keyboard
  • Built-in security digital opening signal
  • Built-in Watchdog to prevent hanging up

Terminal Cables

CN1 (Networking)

Wire Color Description
Black DC 0V (GND)
Red DC 9-24V
Gray Open collector output – Alarm Relay
Purple Negative Trigger Input – R.T.E Door Contact
Orange Negative Trigger Input – Door Contact LED
White Open collector output/Security Trigger Signal – Lock Relay
Green RS-485 B
Blue RS-485 A+

CN3 (WG-READER or KEYBOARD Socket)

Wire Color Description
Blue WG DATA 1
Green WG DATA 0
Red DC 9-24V
Black DC 0V (GND)

Optional Accessories

  • Master Card x2
  • AR-WG-KEYBOARD
  • AR-821-RB or AR-721-RB

Product Usage Instructions

Connect to Electric Strike

Connect to Door Contact and Alarm

Strengthen security with AR-721RB

Connect to Reader or Keyboard

About Master Card

The Master Card is used for setting up and managing tags in the
system. It allows adding and deleting tags as well as accessing
programming mode.

Master Card Setting for Stand-Alone

  1. Use the MASTER CARD software.

  2. Input the MASTER CARD number, and press [Write].

  3. Cut off and then transmit the power, the master card number
    will be activated.

  4. Present the card, and the reader will flash green light 3 times
    and sound 3 beeps.

  5. The card becomes MASTER CARD and accesses programming
    mode.

  6. If MASTER CARD is presented again, it will exit programming
    mode.

Adding Tag

  1. Present Master Card.

  2. After 3 short beeps, access programming mode.

  3. Present the new card or cards one by one until finished
    adding.

  4. Present Master Card to exit programming mode.

Deleting All Tags

  1. 1. Present Master Card.
  2. After 3 short beeps, access programming mode.
  3. After 1 long warning beep after 2 seconds.
  4. After 5 short beeps after 5 seconds, all cards are
    cleared.

P.S. Once MASTER CARD is presented after one warning beep, all
card data will be cleared.

Operation Process

A. Enter/Exit Program Mode

  1. Enter the program mode by inputting 123456 or PPPPPP (Default
    Value = 123456).

  2. If the Master Code has been changed, input the new Master Code
    to access program mode.

  3. Exit the program mode by inputting the Master Code.

B. Set up the password [Only for connect to external K-series

reader]

FAQ

Q: How do I set up the Master Card?

A: To set up the Master Card, use the MASTER CARD software and
follow the instructions provided in the user manual.

Q: How do I add a new tag?

A: To add a new tag, present the Master Card, access programming
mode, and present the new card or cards one by one until finished
adding. Then, present the Master Card again to exit programming
mode.

Q: How do I delete all tags?

A: To delete all tags, present the Master Card, access
programming mode, wait for a long warning beep after 2 seconds, and
then wait for 5 short beeps after 5 seconds. This will clear all
card data.

Q: How do I enter/exit program mode?

A: To enter program mode, input the designated code (e.g.,
123456) or the Master Code. To exit program mode, input the Master
Code.

Q: How do I set up a password for external K-series

reader?

A: Please refer to the user manual for instructions on setting
up a password for external K-series reader.

Geovision PWQGV-R1254 GV-R1254 V200620

Content & Feature

1 Product

2 Terminal Cables

CN1

CN3

FCC ID: PWQGV-R1254

3 Optional

Master Card x2

AR-WG-KEYBOARD

or
AR-821-RB AR-721-RB

4 Feature
Slim design makes installation easy MASTER CARD for adding / deleting tags Set up parameters and user tags by external WG Keyboard Built-in security digital opening signal Built-in Watchdog to prevent from hanging up

Connector Table

Networking: CN1 8 PIN

Application Wire Color Description

CN1 Power

1 Black DC 0V (GND) 2 Red DC 9-24V

8 7 6 5 4 3 2 1 Alarm Relay 3 Gray Open collector output

R.T.E

4 Purple Negative Trigger Input

Door Contact 5 Orange Negative Trigger Input

LED

Lock Relay 6 White Open collector output/ Security Trigger Signal

RS-485

7 Green RS-485 B8 Blue RS-485 A+

(RS-485)

BZ CN3

CN3 WG-READER or KEYBOARD Socket

Application Wire Color Description

1

2

3

4 Blue WG DATA 1

WG

5 Green WG DATA 0

Power

6 Red DC 9-24V 7 Black DC 0V (GND)

Diagram
Connect to Electric Strike

DC POWER
AR-723 (H)
V-(GND) 1 V+ 2 ALM 3 PB 4 SEN 5 Door 6 B- 7 A+ 8

N.O.

EXIT

Request To Exit
Diode

Electric Strike
N.C. N.O. COM CTL
V+
AR-821RB
POWER 12VDC

Connect to Door Contact and Alarm

DC POWER
V-(GND) 1 V+ 2 ALM 3 PB 4 SEN 5 Door 6 B- 7 A+ 8
AR-723 (H)

Alarm
N.C. N.O. COM CTL V+
AR-821RB
N.C.
Door Contact

Strengthen security with AR-721RB

DC POWER

N.O.

EXIT

AR-723 (H)

Request To Exit

V-(GND) 1 V+ 2 ALM 3 PB 4 SEN 5 Door 6
B- 7 A+ 8

N.C.

or

Electric Bolt

Magnetic Lock

N.C.

N.O.

COM

CTL

V+

V-

DECODER

PB

AR-721RB

POWER 12VDC

Connect to Reader or Keyboard

LED BZ CN3

AR-723 (H)

CN3
V- 7 V+ 6 WG0 5 WG1 4
3 2 1

Black Red Green Blue

WG Reader or
WG Keyboard
VV+
WG 0 WG 1

Please unload the cover before plug in AR-WGKEYBOARD.

Access Controller AR-723 (H) V200620

About Master Card
MASTER CARD Setting for Stand-Alone
AR-723 (H)

RS485

Converter

USB

B- 7

A+ 8

321CM

1 2

Use the MASTER CARD software

323DMaster

Input the MASTER CARD number, and press [Write].
Cut off and then transmit the power, the master card number will be activated. Present the card, and the reader will flash green light 3 times and sound 3 beeps. Then the card becomes MASTER CARD and accesses programming mode.If MASTER CARD is presented again, it will exit programming mode.

Adding Tag

Deleting All Tags

1. Present Master Card

1. Present Master Card

2. After 3 short beeps [Access programming mode] 3. Present the new card or cards one by one till finished the adding.
4. Present Master Card [Exit programming mode]

2. After 3 short beeps [Access programming mode] 3. 1 long warning beep after 2sec.
4. 5 short beeps after 5sec: cards cleared
P.S. Once MASTER CARD is presented after one warning beep, all card data will be cleared.

Operation process
A. Enter/ Exit Program Mode
Enter the program mode Input 123456 or PPPPPP [e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input

876112

program mode accessed

Exit the program mode Input

Master Code modification Access programming mode 09 PPPPPPRRRRRR
[e.g.] Set the Master code to be 876112, input 123456

[Input the 6-digit new master code twice.] 09 876112876112

B. Set up the password [Only for connect to external K-series reader]

M4/M8: Individual pass code Card or PIN: Access programming mode 12 UUUUU PPPP Card and PIN: Access programming mode 13 UUUUU PPPP

[e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ] [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]

M6: Public pass word Card or PIN: Access programming mode 15 PPPP Card and PIN: Access programming mode 17 PPPP

[Input 4-digit pass code, default value: 4321] [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

C. Lift control

Connect with AR-401RO16B to control floors which the user will be able to access.

Enable

Access programming mode 24 002 [002= enable lift control] Single floor Access programming mode 27 UUUUU FF UUUU=User Address FF=Floor number (01~32 floor) [e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24

Floor/ Stop
Set F F F F F F F F 0 87654321 1 16 15 14 13 12 11 10 9 2 24 23 22 21 20 19 18 17

Multi floors Access programming mode 21 UUUUU S FFFFFFFF

3 32 31 30 29 28 27 26 25

[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable) [e.g.] User address NO. 168, only to the 6th and the 20th floor: Access programming mode 21 00168 0 00100000 21 00168 2 00001000

Geovision PWQGV-R1254 GV-R1254 V200620

D. Setting Up the Arming [Only for connect to external K-series reader]

Alarm conditions: 1. Arming is enabled 2.Alarm system connected

Application: 1. Door open too long: Door is open longer than door relay time plus door close time. 2. Force open (Opened without a valid user card): Access by force or illegal procedure. 3. Door position abnormal: Arming is enabled and the power is suddenly off then on.

Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234)

Standby Mode

After door open The normal procedure to open door Input 4 digit arming code

Do not open the door Input 4 digit arming code Present valid card

Enter Program Mode

Enable: Access programming mode

Disable: Access programming mode

[The normal procedure to open door] can refer to [Access Mode].

Function Default Value

20 DDD
Function Attendance Auto Re-lock Auto Open Door open button input Master Controller of Network

0: Yes 0: Disable 0: Disable
0: Disable 0: Slave

Selection 1: No 1: Enable 1: Enable
1: Enable 1: Mater

Value 001 002 004 016 032

Default Value
Application Networking Networking/Stand-Alone Networking/Stand-Alone Networking/Stand-Alone Networking

24 DDD
Function Auto-open door without cards at auto open zone Alarm Output/ Lift Control Stop Alarm by door close or by push button

Selection

0: Disable

1: Enable

0: Alarm Output

1: Lift Control

0: None

1: Yes

Value 001 002 064

Default Value
Application Networking/Stand-Alone Networking/Stand-Alone Networking/Stand- Alone

28 DDD
Function Dual Door Control Force Open Alarm Output

0: Disable 0: Disable

Selection 1: Enable 1: Enable

Value 064 128

Default Value
Application Networking/Stand-Alone Networking/Stand-Alone

Selection= 0(none value)/ 1(1 x each value) [e.g.] DDD value of Enable “Auto Open” + “Exit by Push Button + “Anti-pass-back”
=(0x1)+(0x2)+(1X4)+(1×16)+(0x32)+(0x64)+(1×128)=148 ; As a result of that, the command will be 20

148 .

Mode4 / Mode6 / Mode8

Mode

Networking/ Stand-Alone

Networking/ M4
Stand-Alone

M6 Stand-Alone Networking/
M8 Stand-Alone

User Capacity
1,024
65,535
1,024

Access Mode
1.Card only 2.Card and PIN (4-digit PIN)+ 3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) + 1.Card only 2.Card and PIN (4-digit public PIN= Arming PWD)+ 3.Card or PIN (4-digit public PIN= Duress code) 1.Card only 2.Card and PIN (4-digit individual PIN)+ 3.Card or PIN (4-digit individual PIN)

Auto-show Event log 120 Duty time Capacity Holidays

Yes

1,200

Yes

No

No

No

Yes

1,200

Yes

Anti force Yes
No
Yes

Time Lift Anti-passZone Control back

No

32

Yes

No

No

No

No

32

Yes

Mode 6, the number of users up to 65535, since it reads CARD CODE(5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE(10 digits). If Access Mode setting to use the PIN, it need to external the K-series Readers.

Factory Reset by its commands
When the device is stand-alone (not networking) Access programming mode 20 016 24 064 26 00000 01023 1 28 000 Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.

29 29

Access Controller AR-723 (H) V200620

Command List

Function
Entering programming mode

Command
PPPPPP

Exiting programming mode

Exiting programming mode and enabling arming status

Node ID setting (Connecting to 716E

00

Node ID setting (Connecting to PC directly without
00
via 716E)

NNN NNN

VVV

nnn

Mifare tag / card format (Optional)

01 N

Door relay time setting
Alarm relay time setting Control mode setting Arming delay time setting Alarm delay time setting
Master card setting

02 TTT
03 TTT 04 N 05 TTT 06 TTT
07 SSSSS EEEEE

Auto-open time zone setting

08 N HHMMhhmm 6543217H

Master code setting

09 PPPPPPRRRRRR

Suspend tag(M6)

10

Setting

Delete tag(M4)

10

Set a sequence of cards as “read and access”

11

Active the suspended cards

11

Set the cards as Card mode OR PIN mode by user
12
address

Set the cards as Card AND PIN mode by user
13
address

M4: Duress code setting
15
M6: Public PIN setting (Card or PIN)

SSSSS EEEEE SSSSS 9 EEEEE SSSSS EEEEE SSSSS EEEEE UUUUU PPPP
UUUUU PPPP
PPPP

Card number modification

16 UUUUU SSSSSCCCCC

M4: Arming pass code setting M6: Public PIN setting (Card and PIN) Door open waiting time

17 PPPP 18 TTT

Set the card by induction (M4)

19 UUUUU QQQQQ

Reader additional setting

20 DDD

Lift control setting: multi-doors

21 UUUUU S FFFFFFFF

Add/Delete tag by induction (M6 only) AR-401ROsite number dip switch Controller parameter setting Controller time clock setting

22 N 23 NNN TTT 24 DDD 25 YYMMDDHHmmss

Anti-pass-back (Enable user)

26 SSSSS EEEEE N

Single floor setting

27

Dual door control/ Active or inactive arming for force open 28

Delete all tags

29

34
Enable the security trigger signal ( with AR-721RB)
34

UUUUU FF DDD 29 064 (Enable) 000 (Disable)

Description
PPPPPP=Master Code, default value=123456
NNN=Node ID, range: 001~254 NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, nnn=Door number; range:001~254

Mode
M4/M6/M8 M4/M6/M8 M4/M8 M4/M8
M4/M8

N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693; 3=I Code1; 4=I Code2
PS.1. Please select the compliance,first. 2. Make sure reader and card using the same compliance.

M4/M8

TTT=Door relay time 000= Output constantly 001~600=1~600 sec. 601~609=0.1~0.9 sec.
TTT=Alarm relay time 001~600=1~600 sec. N=Mode 4=Mode4; 6=Mode6; 8=Mode8 TTT=Alarm relay time 001~600=1~600 sec. TTT=Alarm delay time 001~600=1~600 sec.

M4/M6/M8
M4/M6/M8 M4/M6/M8 M4/M6/M8 M4/M6/M8

SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H); SSSSS=Starting user address; EEEEE=Ending user address

M4/M8

N= 0(1st time zone) / 1(2nd time zone) HHMM= Starting time; hhmm= ending time (i.e.: 08301200=08:30 to 12:00) 6543217H= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun)+ Holiday (F= 0: disable; 1: enable); Holidays establish by the software.

M4/M6/M8

PPPPPP=New master code RRRRRR=Repeat the new master code
=Suspend 9 =Delete;
SSSSS=Starting user address, EEEEE=Ending user address SSSSS=Starting card number; EEEEE=Ending card number SSSSS=Starting user address; EEEEE=Ending user address Access mode: Card or PIN; UUUUU=user address;
PPPP=4-digit pass code 0001~9999 Access mode: Card and PIN; UUUUU=user address;
PPPP=4-digit pass code 0001~9999

M4/M6/M8 M4/M6/M8 M6 M4/M8 M4/M8 M4/M8
M4/M6/M8

PPPP=4-digit pass code (default value=4321) P.S. Duress code will be unavailable and become a public PIN at access mode “Card or PIN” of M6

M4/M8

UUUUU= User address; SSSSS=5-digit site code; CCCCC=5-digit card code

M4/M6/M8

PPPP=4-digit pass code ( default value=1234; disable Arming PWD=0000)
M4/M6/M8
P.S. Arming PWD code will be unavailable and become a public PIN at access mode “Card PIN” and of M6
TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec. M4/M8

UUUUU=User address; QQQQQ=Card quantity(00001=Continuously inducting) Please refer to function default value for details. UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor (F=0: Disable, 1: Enable) N=0(Delete tag); N=1(Add tag) NNN=site number, TTT= relay time: 000~600=1~600 sec. Please refer to function default value for details. YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec. SSSSS=Starting user address; EEEEE=Ending user address; N=0/Enable; N=1/Disable; N=2/Initial UUUUU=User Address; FF=Floor (01~32 floor) Please refer to function default value for details.
Change the “Door Lock” become the security trigger signal when connecting with AR-721RB.

M4/M6/M8
M4/M6/M8
M4/M8
M6 M4/M8 M4/M6/M8 M4/M6/M8
M4/M8
M4/M8 M4/M6/M8 M4/M6/M8
M4/M6/M8

Geovision PWQGV-R1254 GV-R1254 V200620
FCC ID: PWQGV-R1254
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure statement. The device can be used in portable exposure condition without restriction
Warning: Changes or modifications to this unit not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals