IN-006-010 Digital Level Control Switch
Product Information
Specifications:
- Model: IN-006-010, IN-006-020
- Cord Length: 10 feet (IN-006-010), 20 feet (IN-006-020)
- Range: 6 inches
Features:
- First of its kind, solid-state sensing technology with nomoving parts.
- Space age design with no mechanical contact points.
- Multipoint sealing mechanism that supersedes single surface seals.
- Inverter rated for use with any battery back-up system.
- Standard piggy back connection for use with any pump.
- Suitable for sump and sewage applications.
Product Usage Instructions
Piggy-Back Installation:
To ensure proper installation and prevent flooding, follow these steps:
- Ensure the electrical outlet is not located in the pump pit.
- Make sure the electrical outlet voltage, piggy-back plug voltage, and pump voltage are all the same.
- DO NOT CUT the plug off the unit.
- Protect the vent tube on the plug from moisture, dirt, insects, and other items that could plug or block it.
- Plug the pump into the piggy-back plug.
- Allow the system to cycle to ensure proper installation.
Note: This product may not work in conjunction with other controllers.
Safety Precautions:
Follow these safety precautions to prevent electric shock and ensure proper installation:
- Connect the product to a grounded outlet.
- The electrical outlet should be properly wired to a dedicated 15A circuit breaker.
- Proper short-circuit and overload protection must be provided at the distribution panel.
- Install in accordance with all local and national electrical codes.
- Do not place the electrical outlet in the pump pit.
- Avoid using electrical extension cords for best performance.
Installation Drawing:
Refer to Figure A (optional bracket) and Figure B, C, D (range and pump off level) for proper installation.
Troubleshooting:
If you encounter any issues with the switch or pump, follow these troubleshooting steps:
- Plug the pump directly into the wall outlet, bypassing the switch plug. If the pump does not run, refer to the troubleshooting section in the pump manual.
- If the pump runs, test the switch with the pump:
- Push up on the sensing plate through the diaphragm surface (do not use sharp objects).
- If the pump does not turn on, the switch will need to be replaced.
- If the pump turns on, proceed to the next step.
- Verify the range of the switch:
- Check the part number on the switch cord tag (IN-006… = 6-inch range).
- For a pipe-mounted switch, refer to the Installation Drawing on Page 2 to ensure the on level is appropriate for your basin.
FAQ
Q: Can I use this switch with other controllers?
A: This product may not work in conjunction with other controllers. It is recommended to use it independently.
FEATURES
- First of its kind, solid-state sensing technology with no moving parts.
- Space age design with no mechanical contact points.
- Multipoint sealing mechanism that supersedes single surface seals.
- Inverter rated for use with any battery back-up system.
- Standard piggy back connection for use with any pump.
- Suitable for sump and sewage applications.
PIPE MOUNTING BRACKET (OPTIONAL)
- Determine bracket mounting position (Figure A).
- Mount bracket to Ion® switch with screw already provided in Ion® switch (Figure B).
- Mount hose clamp with switch around pipe at predetermined level. Cable should remain outside hose clamp (Figure C).
- Tighten hose clamp.
Note: The Ion® switch is available in a 6” range. The range of the switch is the distance between the On and Off levels. The Off level is at the bracket mounting screw of the switch. From this point, measure up 6” to find the On level. Please refer to the Installation Drawing.
CAUTION: Bottom of switch should not be mounted lower than suction inlet of pump. When installing the Ion® switch with the pipe mounted bracket be sure not to set the switch too low or too high on the pipe. The Ion® switch must be installed above the inlet of the pump to prevent air-locking as shown in the installation drawing. To prevent flooding do not set the on point of the switch higher than the top of the basin.
Model | Cord | Range |
---|---|---|
IN-006-010 | 10 | 6 |
IN-006-020 | 20 | 6 |
PIGGY-BACK INSTALLATION
- Electrical outlet must not be located in pump pit.
- Electrical outlet voltage, piggy-back plug voltage and pump voltage must all be the same voltage.
- DO NOT CUT plug off unit.
- Ensure vent tube on plug is protected from moisture, dirt and insects and other items that could plug or block tube.
- Insert the Ion® switch’s piggy-back plug into the outlet.
- Plug pump into piggy-back plug as (Figure E).
- Allow system to cycle to ensure proper installation.
Please note this product may not work in conjunction with other controllers.
SAFETY PRECAUTIONS
CAUTION: To prevent electric shock, ensure product is connected to a
grounded outlet.
The electrical outlet should be properly wired to a dedicated 15A circuit
breaker. Proper short-circuit and overload protection must be provided at the
distribution panel. Install in accordance with all local and national
electrical codes.
WARNING: Electrical outlet must not be located in pump pit. For best performance, do not use electrical extension cords.
INSTALLATION DRAWING
NOTE: If you purchased a pump with the Ion switch hard-mounted to the pump (Figure D) and the installation requires the switch to be mounted to the pipe, the pipe-mount bracket is sold separately, PN: IN-SPB1-1.
TROUBLESHOOTING
Switch Does Not Turn On Pump
-
Test the pump without the Ion® switch
-
a. Plug the pump directly into the wall outlet, without plugging it into the switch plug.
-
b. If pump still does not run, see the troubleshooting section in the pump manual.
-
c. If the pump does run, continue to the next step.
-
Test the switch with the pump
-
a. Plug the pump into the Ion® switch and plug the Ion switch plug into the wall.
-
b. Push up on the sensing plate through the diaphragm surface. Please don’t use any sharp object to push against the diaphragm. You may hear a small click sound when the pump is turned on.
-
c. If the pump does not turn on, the switch will have to be replaced.
-
d. If the pump does turn on, continue to the next step.
-
Verify the range of the switch
-
a. The part number can be found on the switch cord tag.
IN-006… = 6” range -
b. For a pipe-mounted switch, see Page 2, Installation Drawing to verify that the On level is appropriate for your basin.
Lower the switch on the pipe so the On level is at a point within the basin, insuring that the Off level does not fall below the minimum level shown in the Installation Drawing.
If the On level is still too high, the switch will have to be replaced with a lower range Ion® switch. -
c. For a pump-mounted switch, see Page 2, Figure D to verify that the On level is appropriate for your basin.
If the On level is too high, the switch will have to be replaced with a lower range Ion switch.
-
Switch Does Not Turn Off Pump
- Unplug the pump from the Ion® plug and then unplug the Ion plug from the wall outlet.
- Plug the pump back into the Ion® plug and plug the Ion plug back into the wall outlet.
- If the pump does not turn on right away, and the water level is not at the On level, let the pump go through an On / Off cycle a few times to insure that the switch is functioning properly. The basin may need to be filled with a garden hose or bucket.
- If the pump turns on right away, and the water level is not at the On level, the switch will have to be replaced.
WARRANTY IS VOID IF…
- Using an extension cord.
- Power cord has been cut or the grounding prong removed or using an adapter fitting.
- The switch has been disassembled or tampered with.
- Any tags or labels have been removed.
- Used in a heavy grease application
- Used in applications exceeding the designed temperature range of 32 – 104 degrees F.
3 Year Residential Warranty
- Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each Ion|StormPro product (the “product”), that any part thereof which proves to be defective in material or workmanship within three (3) years from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B. factory. Buyer shall be responsible for all freight charges and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof.
- Exclusions. THE WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND EXCLUSIONS:
- (a) The Warranty excludes products or workmanship which becomes defective as a result of: (i) earthquake, fire, storms, the elements or any other acts of God; (ii) normal wear and tear from use; (iii) accident, misuse, abuse or neglect; (iv) modifications made by Buyer or any third party, other than Metropolitan; and (v) Buyer’s failure to properly install, maintain, service and/or operate the product under normal conditions and according to manufacturer’s instructions.
- (b) Metropolitan shall not be responsible for, and the Warranty shall not cover, extended damage which occurs because of Buyer’s failure to notify Metropolitan promptly in writing of apparent defects.
- (c) Any part or component designated as manufactured by anyone other than Metropolitan shall be covered only by the express warranty of the manufacturer thereof.
- (d) The Warranty shall lapse upon Buyer’s failure to fully comply with the terms and conditions of its contract with Metropolitan, including Buyer’s failure to pay the purchase price for the product or any portion thereof. Buyer’s subsequent compliance with the terms and conditions of any such contract, will not cause the term of the Warranty to extend beyond the time period set forth above.
- (e) No actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above. Metropolitan shall not be obligated to remedy any defect, where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above.
- Process of Claims and Repairs. Metropolitan agrees that if the product or any part or component thereof shall fail to conform to the terms of this Warranty, Metropolitan shall replace such nonconforming product, part or component at the original point of delivery and furnish instruction for its disposition. Any transportation charges involved in such disposition and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof shall be the responsibility of Buyer.
- Limitation on Liability. Notwithstanding any provision to the contrary, Metropolitan’s entire liability under this Warranty shall not in the aggregate exceed, and Buyer’s exclusive and sole remedies are, to the extent permitted by law, shall be to secure replacement of the defective product. UNDER NO CIRCUMSTANCES SHALL METROPOLITAN BE LIABLE UNDER THE WARRANTY FOR ANY INDIRECT, PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING LOST PROFITS, REVENUE, USE OR ECONOMIC ADVANTAGE).
- Express Waiver of Any Other Warranties. THE EXPRESS WARRANTY SET FORTH IN THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY METROPOLITAN, OR ANY OTHER PARTY, IN CONNECTION WITH ANY PRODUCT PURCHASED FROM METROPOLITAN. NEITHER METROPOLITAN, NOR ANY OTHER PARTY, MAKES ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH IS NOT SET FORTH HEREIN, AND METROPOLITAN HEREBY DISCLAIMS AND BUYER HEREBY WAIVES ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
- Not Transferable. The Warranty may not be transferred and shall be void on the sale or other transfer of the product.
- Products and Warranty Subject to Change. Metropolitan reserves the right to make revisions to its products and their specifications, and to revise this Warranty and related information without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>