Specifications
- CO2-W Dimensions: 84mm x 29mm x 58mm
- CO2-D Dimensions: 116.5mm x 53.7mm x 112.5mm
- Electrical: 24VAC, 120VAC
Product Usage Instructions
Overview
The CO2 Sensor is an accessory for EV-Series, SL-Series, EV Premium, HE-
Series, and LE-Series products.
Dimensions
-
CO2-W
Dimensions: 84mm x 29mm x 58mm -
CO2-D
Dimensions: 116.5mm x 53.7mm x 112.5mm
Electrical
Wiring Schematics
Refer to the following wiring schematics for different units:
- Wiring Schematic for EV90, EV90P, EV130, EV200, EV240, EV300 Units Only
- Wiring Schematic for EV Premium and SL75 Units
- Wiring Schematic for HE1.5IN Units without ECM
- Wiring Schematic for HE1.5RT, LE-Series, and all HE2X and Larger Units without VFDs or ECM
Factory Assistance
If you require any further assistance, please contact our factory at
1.800.627.4499.
FAQ
-
Q: What are the dimensions of CO2-W?
A: The dimensions of CO2-W are 84mm x 29mm x 58mm. -
Q: What are the electrical requirements for the CO2 Sensor?
A: The CO2 Sensor requires 24VAC and 120VAC electrical connections. -
Q: Where can I find the wiring schematics for different units?
A: The wiring schematics for different units can be found in the user manual or by referring to the figures provided in this manual.
Models
- EV-Series
- SL-Series
- EV Premium
- HE-Series
- LE-Series
OVERVIEW
The CO2 monitor uses a highly accurate and reliable Non-dispersive Infrared (NDIR) with state-of-the-art digital linearization and temperature-compensated circuitry to detect CO2 levels in an attractive, low profile enclosure for room applications and a duct mount version. It provides a linear analog signal output of 4–20 mA, 0–5, or 0–10 VDC and a Normally Open (NO) relay to control an alarm or ventilation fan in various ways.
DIMENSIONS
CO2-W
CO2-D
ELECTRICAL
WIRING SCHEMATICS
FIGURE 3.1.0 WIRING SCHEMATIC FOR EV90, EV90P, EV130, EV200, EV240, EV300 UNITS ONLY
In this example, the CO2 Controller turns the Energy Recovery Ventilator (ERV) on at High speed when the CO2 level exceeds the CO2 Controller Relay setting.
FIGURE 3.1.1 WIRING SCHEMATIC FOR EV PREMIUM AND SL75 UNITS
FIGURE 3.1.2 WIRING SCHEMATIC FOR HE1.5IN UNITS WITHOUT ECM
FIGURE 3.1.3 WIRING SCHEMATIC FOR HE1.5RT, LE-SERIES, AND ALL HE2X AND LARGER UNITS WITHOUT VFDS OR ECM
FIGURE 3.1.4 WIRING SCHEMATIC FOR HE-SERIES AND LE-SERIES UNITS WITH FACTORY- INSTALLED VFDS
FIGURE 3.1.5 WIRING SCHEMATIC FOR HE1.5 UNITS WITH ECM AND TERMINAL BLOCK
In this example, the CO2 Controller turns the ERV on at a speed set by potentiometers when the CO2 level exceeds the CO2 Controller Relay setting.
FIGURE 3.1.6 WIRING SCHEMATIC FOR HE07, HE10, AND HE1.5 UNITS WITH ECM AND CIRCUIT BOARD
In this example, the ERV does not run while unoccupied, set by the timer. During occupancy, ERV runs at variable Speed. CO2 Controller sets speed based on CO2 levels. Remove the potentiometers by cutting the wires at the potentiometer. Cap the orange and purple wires from the potentiometer with wire nuts. HE07, HE10, and HE1.5 Circuit Board have two potentiometers and the cut wires can be wired in parallel back to the CO2 Controller.
FIGURE 3.1.7 WIRING SCHEMATIC FOR HE07, HE10, AND HE1.5 UNITS WITH ECM AND CIRCUIT BOARD AND TIMER
FACTORY ASSISTANCE
In the unlikely event that you need assistance from the factory for a specific issue, make sure that you have the information called for in the Unit Records page in the Owner Information section of the unit manual. The person you speak with at the factory will need that information to properly identify the unit and the installed options.
To contact RenewAire Customer Service:
- Call 800-627-4499
- Email: RenewAireSupport@RenewAire.com.
About RenewAire
For over 40 years, RenewAire has been a pioneer in enhancing indoor air
quality (IAQ) in commercial and residential buildings of every size. This is
achieved while maximizing sustainability through our fifth-generation, static-
plate, enthalpic-core Energy Recovery Ventilators (ERVs) that optimize energy
efficiency, lower capital costs via load reduction, and decrease operational
expenses by minimizing equipment needs, resulting in significant energy
savings. Our ERVs are competitively priced, simple to install, easy to use and
maintain, and have a quick payback. They also enjoy the industry’s best
warranty with the lowest claims due to long-term reliability derived from
innovative design practices, expert workmanship, and Quick Response
Manufacturing (QRM).
As the pioneer of static-plate core technology in North America, RenewAire is the largest ERV producer in the USA. We’re committed to sustainable manufacturing and lessening our environmental footprint, and to that end our Waunakee, WI plant is 100% powered by wind turbines. The facility is also one of the few buildings worldwide to be LEED® Gold and Green Globes certified, as well as having achieved ENERGY STAR Building status. In 2010, RenewAire joined the Soler & Palau (S&P) Ventilation Group to provide direct access to the latest in energy-efficient air-moving technologies. For more information, visit renewaire.com.
201 Raemisch Road | Waunakee, WI | 53597 | 800.627.4499 | RenewAire.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>