ELECTRIC BATHROOM HEATER
**User Manual
VARILLA**
Varilla 1.02 Electric Bathroom Heater
v. 1.02
Symbols description
The symbols used in this manual are intended to draw your attention to
possible hazards.
The safety symbols and accompanying explanations must be properly understood.
Warnings in themselves do not remove hazards and cannot replace correct action
to prevent accidents.
This symbol warns or informs about a danger. Ignoring this warning may result
in injury to yourself or others. To reduce the risk of injury, fire or
electric shock, always follow these instructions with the safety rules given
in this manual.
**** The product complies with the essential requirements of the European
Union directives.
Thank you for purchasing our product.
Please read this user manual carefully before using this product for the first
time and keep it safe for future reference.
The latest version of the Manual is available on our website:
www.warmtec.pl
SAFETY RULES
Please read this manual before installing and using the device.
Due to conwork aimed at improving the quality of the product, there may be
changes in the product design that are not included in this manual, but do not
affect the product’s performance. The latest version of the manual, including
all changes, is available at www.warmtec.pl.
- The device is intended for non-commercial use only as a headevice for small rooms.
- Observe the generally recognized accident prevenon regulaons and the enclosed safety instruc
- Follow these instruc
- The manufacturer is not liable for damage caused by improper use.
- Before using the device for the first the user is obliged to read and understand this manual in order to use it safely.
- Follow all safety instrucSkipping some procedures can cause harm to you and others.
- Keep all operainstrucand safety instrucfor future reference.
- If the device is sold or transferred, the user must also hand over these operainstruc
- Never use the device in a room where there is a risk of explosion or near flammable liquids or gases.
- Always ensure that there is no chance of the device accidentally turning on aer it has been turned off.
- Do not overload the device. Do not use the device for purposes for which it is not intended.
- Be careful and use the device only when you are in good physical condi Do not use the device in case of alcohol consumpillness or aer consumpof other substances that may affect the state of consciousness
- Always comply with all applicable naand internasafety, health and occupalaws.
- The device may only be connected to a socket that is properly installed and grounded.
- The fuse must be a residual current device with a measured residual current power of not more than 30 mA.
- Before connecting, make sure that the power supply complies with the connection specification of this device.
- The device may only be used within the specified voltage range (see rating plate).
- Do not touch the mains plug with wet hands! From the mains socket, always pull by the plug and not by the cable.
- Do not bend, crush, pull or run over the device cable, protect it from sharp edges, oily substances and from overheating.
- Do not lift the device by the cable and do not use the cable for purposes other than intended.
- Inspect the plug and cable before each use.
- If the power cord is damaged, disconnect the plug immediately. Never use the device if the power cord is damaged.
- When the device is not in use, make sure that the plug is pulled out.
- Before disconnecting the device, make sure it is turned off.
- Disconnect the power supply if you want to move the device to another location.
- If the mains cable is damaged, it must be replaced by the manufacturer or its service agent or by other qualified persons in order to eliminate the source of danger!
- Always keep this instruction manual within reach.
- When installing, take into account the routing of other installations in or on the walls, such as electricity, water and gas lines.
- The device must not be used near flammable/explosive substances and materials
- The device is not suitable for external use.
- The device must not be left unattended in operating mode.
- The device heats up during operation. There is a risk of injury!
- The device must not come into contact with water or other liquids.
- The device must not be powered by an external switching device, such as a timer, or connected to an on/off circuit due to the risk of fire.
- The device must not be placed under a wall socket.
- Do not connect the device to adapters or extension cords.
- Children aged 8 years and over and persons with limited physical, sensory or mental abilities or persons without adequate knowledge and experience may use the device under supervision or after prior training in the safe use of the device, being aware of the resulting risks!
- The device must not be used by children to play with. Cleaning and user maintenance must not be performed by children without supervision!
- Children under the age of 3 should be kept away from the appliance unless they are constantly supervised!
- Children over the age of 3 but under the age of 8 may switch the appliance on and off, provided that the appliance is placed or installed in its normal position of use and that they are supervised or trained in the safe use of the appliance and are aware of the resulting risks. Children over the age of 3 but under the age of 8 may not plug in the appliance, adjust its operation, clean or maintain the appliance.
Some parts of the device can become very hot, causing burns. It is recommended to pay special attention if there are children or people in need of care nearby!
INSTALLATION
Necessary or useful tools
Kit components
Sequence of accessories installation Remember to install it in the appropriate zone of the bathroom. In the case of the Varilla heaterBefore mounting the heater, mark the dowel holes for the wall brackets on the wall. Then, use a drill to drill the holes.
|
---|---
|
|
OPERATION
The device may only be put into operation if it is faultless.
Before starting, it is absolutely necessary to check the device in terms of
whether:
a) there are no visible defects,
b) all parts of the device are fixed.
Description of the control panel and icons on the display
| on/off button
---|---
| mode button
| increase button
| decrease button
| clock
---|---
| the day of the week
| programmable mode (from P1 to P7)
| temperature
| comfort mode
| economy mode
| anti-frost mode
| programmable mode
| open window detection function
| child lock
| heating on timeline with heating blocks
| anti-scald function activated
The heater can operate in manual and programmable mode. Manual mode is one in which the desired mode (comfort, economy or free frost) is set and the heater constantly works in this mode. In the case of the programmable mode, you can arrange the heater’s operation program separately for each day of the week, assigning each hour a selected mode (comfort or economy). In the programmable mode, it is not possible to assign the frost free mode.
Comfort mode
The default temperature in comfort mode is 19°C.
Economy mode
In the economy mode, it is possible to set the temperature lower than or equal
to the temperature in the comfort mode. By default, the temperature in economy
mode is 15.5°C.
Anti-Frost mode
In this mode, the device will turn on when the temperature is below 7°C and
turn off when the temperature is above 7°C. In the case of anti-frost mode, it
is not possible to set the temperature.
Switching between modes is possible with the V button. It allows you to select the comfort, economy, anti-frost mode in manual mode or switch to the programmable mode. The mode in which the heater is currently operating is indicated by the icon at the top of the display. The temperature is set using the + or – buttons. The temperature in the comfort and economy modes can be set in the range of 7 ° C … 30 ° C. To change the temperature in a given mode, it must be done during the heater operation in this mode.
Time setting
When using for the first time, a long period of non-use, or a power outage,
you will need to set the time and day of the week. Time and day of the week
settings can only be made when the programmable mode icon is shown on the
display. If it is not there, switch the mode with the V button until the
programmable mode icon appears.
To start setting the time and day, press and hold the V button for 3 seconds
until the first two digits flash on the display. Use the + and – buttons to
set the hour from 0 to 23. After 30 seconds of inactivity, it will
automatically go to the minutes setting. Press the V button to enter the
minute setting. As with the hours, you can set the minutes with the + and –
buttons. After 30 seconds of inactivity, it will automatically go to the day
of the week settings. Press the V button to enter the day of the week setting.
As with the hours and minutes, you can set it using the + and – buttons. The
numbers on the display correspond to the day of the week: 1 = MONDAY, 2 =
TUESDAY, 3 = WEDNESDAY, 4 = THURSDAY, 5 = FRIDAY, 6 = SATURDAY, 7 = SUNDAY.
After setting the current day of the week, press V to confirm. You will then
go to the programmable mode settings. If you do not confirm the day of the
week with the V button for 30 seconds, the time settings will be saved
automatically and you will go to the programmable mode settings. The
programming process is described in the further part of the manual. If you do
not want to program the heater, keep pressing the V button until you return to
the home screen.
Weekly programming – setting
A suitable program can be assigned to each day of the week. Same as 1 (next to
the hour and minutes) for Monday, 2 for Tuesday, 3 for Wednesday, etc., then
P1 is the program for Monday, P2 for Tuesday, P3 for Wednesday, etc. until P7
is the program for Sunday. Depending on your needs, you can leave the default
programs set (as below) or set any program for each day of the week, in which
the appropriate mode (comfort or economy) will be assigned to each hour. The
comfort mode on the display is presented as a rectangle above the time to
which it has been assigned. Economy mode, on the other hand is presented as
lack of this symbol.
Default programs P1-P7
When the heater is started for the first time, and after each factory reset,
the program for each day of the week is the same and is as follows:
Comfort mode 5:00 – 23:59 (except the stated hours, it works in economy mode)
Setting programs P1 – P7 according to your preferences
Programmable mode settings can only be made when the programmable icon is
shown on the display. If it is not there, switch the mode with the V button
until the programmable mode icon appears. Press and hold the V button for 5
seconds. You will go to the time settings described earlier. If you want to
set them, follow the previously described procedure. Note that for the
programmable mode to work properly, it is necessary to set the current time
and day of the week. If you have set the time and day of the week in advance
and they do not need to be changed, press the V button until you enter the
programmable mode setting. This will be evidenced by the displayed symbol P1.
Go to the program settings for Monday or select the day you want to program by
pressing the V button. If you want to program the heater for Tuesday, press
the V button until the display shows the program corresponding to Tuesday,
i.e. P2. To enter the program edit mode, press and hold the V button. P2:00
will appear on the display. By pressing + and – you assign a given operating
mode (comfort mode – button + or economy mode – button -) to each hour,
starting from 00 and ending with 23. If you already assign modes to all 24
hours, press the V button to confirm the selection and V again to advance to
the programming of the next day. After 30 seconds of inactivity, it will
automatically go to the next day’s settings. With the V button you can move to
the next days and program them in the same way as described above. Once you
have programmed your desired days, click the V button until you return to the
start screen.
Child lock
To avoid accidental operation of the heater, the user can set a child lock to
block control of the device. The child lock can be activated by simultaneously
pressing and holding the + and – buttons for 5 seconds until the child lock
icon appears on the display. In this mode, all buttons except on/off are
inactive. The child lock can be turned off by pressing and holdingthe + and –
buttons for 5 seconds until the child lock icon disappears from the display.
Settings
In the standby mode (the heater is connected to the power supply, but not
turned on), press and hold the + button for 10 seconds. Using the V button,
you can switch the set item in the menu, and using the + or – buttons change
its parameters:
(F0) Temperature measurement calibration
(F1) Open window detection function
(F2) Anti-scald function
Temperature measurement calibration (F0)
It is used to correct the temperature reading when it is incorrect. In the
settings menu at the F0 item, use the + and – buttons to set the calibration.
The setting range is 5°C to -5°C (every 1°C). The default calibration value is
-2°C. Press the V button to save the settings and move to the next menu item.
Open window detection function (F1)
If the room temperature drops by 5°C within five minutes, the heater will
operate at a temperature setting of 10°C for a period of time. This time is
selected by the user. It can be 60 or 90 minutes. After the set time has
elapsed, the heater will return to the operating mode that was active before
the open window detection function started. In the settings menu, press V
until (F1) appears on the display. Use the + and – buttons to select the time
(0, 60 and 90 minutes) after which the heater should return to the active
operating mode before the open window detection function is activated. Setting
the value to 0 deactivates the function. The default value is 0. Press the V
button to save the settings and go to the next menu item.
Anti-Scald function (F2)
If the surface of the heater reaches the temperature assigned to the anti-
scald function, heating will be stopped until the temperature of the surface
of the heater drops. Press the + button to increase or – to decrease the
temperature assigned to the anti-scald function. You can choose from the
following temperature settings: 40, 45, 50, 55 and 60°C. Setting the oF value
disables the function. oF is the default value. Press the V button to save the
settings and move to the next menu item.
When the open window detection function and the anti-scald function are turned
on at the same time, only the open window detection icon will appear on the
display. However, the anti-scald function will be enabled.
The next item is the F3 function, which does not affect the operation of the
heater. Skip setting it by clicking the V button.
Memory backup function after power failure
If there is a sudden power failure, the heater’s current operating time
settings are retained at the time of power failure. When the power is
restored, the heater automatically turns on and returns to the previous
operating mode, except for the time, which must be set again. In order for the
memory backup function to work, any changes to the heater settings must be
made. By default (when nothing has been set and the heater has only been
connected to the power supply), the memory backup function is not enabled.
Return to factory settings
After pressing and holding the on/off button for 10 seconds, the heater
settings will be restored to the factory settings, i.e. (temperature in
comfort mode – 19°C, temperature in economy mode – 15.5°C, time – 12:00, day
of the week – 1 (Monday), P1 – P7 – initial settings, temperature measurement
calibration – -2°C, open window detection function – 0, antiscalding function
CLEANING AND MAINTENANCE
Cleaning and maintenance
Never use detergents or solvents for cleaning. This may cause irreparable
damage to the product. Plastic parts can be destroyed by chemicals.
- Turn off the appliance and let it cool down completely.
- Pull out the plug.
- Wipe the device with a slightly damp cloth.
TROUBLESHOOTING
Failures are often caused by minor faults. Most of them you can easily solve yourself. Please refer to the table below before contacting with the manufacturer’s service.
Issue | Questions concerning the issue | Solution |
---|---|---|
– The device does not heat up | – Is the device turned off? |
– Are the temperature settings set too low?
– No mains voltage.| – Switch on the device and set the desired one heat
level.
– Set a higher temperature.
– Check cables, plugs, sockets and fuses.
If you are unable to repair the fault yourself, please contact your nearest dealer. Please note that any incorrect repairs will also void the warranty and you may incur additional costs.
Error codes
on a display instead of temperature indication there is Er| Temperature sensor
shortcircuited or the temperature exceeds 55°C
---|---
TECHNICAL SPECIFICATIONS
Model: | 500 W |
---|---|
Power | ~230 V / 50 Hz |
Voltage / Frequency | I |
Protection class | IP24 |
IP rating | 54 x 96 x 4,3 cm |
Dimensions (W x H x D) | Varilla |
Data and product information in accordance with Directive 2009/125/EC.
PL – Information requirements for electric local space heaters.
Model ID: | Varilla |
---|
Heat output:
Nominal heat output Pnom (kW)| 0,5
Minimum heat output (indicative) Pmin (kW)| N/A
Maximum constant heat output Pmax (kW)| 0,5
Consumption of electricity for own needs
At nominal heat output elmax (kW)| N/A
At minimum heat output elmin (kW)| N/A
In standby mode elSB (kW)| 0,00066
Type of heat output /room temperature control| with electronic room
temperature control plus week timer
Other control options| room temperature control, with open window detection
Contact details| WARMTEC Sp. z o.o. , Al. Jana Pawła II, 27 00-867 Warszawa
ENVIRONMENTAL PROTECTION AND RECYCLING
INFORMATION ABOUT WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
We hereby would like to inform you that the main purpose of European regulaand
the Act of September 11, 2015 on waste electrical and electronic equipment is
to reduce the amount of waste arising from the equipment, to ensure an
appropriate level of collecreuse and recycling of spent equipment, and to
increase public awareness of its harmfulness to the natural environment at
every stage of the use of electrical and electronic equipment.
Therefore, it should be pointed out that households play a key role in
contributo re-use and recovery, including recycling of waste equipment. User
of equipment intended for households is obliged to hand over the waste of
electronics that are no longer usable to an authorised collector. However, you
should remember that products belonging to the group of electrical or
electronic equipment should be disposed of by an authorised person to their
collecpoints.
You can return spent device to the shop where you will also buy a new one. The
CCR REEWEEE recycling organisation, which we have signed a contract with, will
pick it up.
ATTENTION! THE DEVICE MUST NOT BE DISPOSED IN HOUSEHOLD WASTE.
**** This crossed-out wheeled bin symbol indicates that the product must not
be disposed of with household waste across EU. The used product must be
recycled in order to prevent possible damage to the environment or health. In
accordance with applicable law, non-usable powered by electricity devices
should be collected separately, in specially designated locations, in order to
process and reuse them, on the basis of the applicable environmental standards
(WEEE Directive 2012/19/EU).
NOTES
WARMIEC Sp. z 0.0.
Al. Jana Pawta || 27
00-867 Warszawa
Documents / Resources
|
Warmtec Varilla 1.02 Electric Bathroom
Heater
[pdf] User Manual
Varilla 1.02 Electric Bathroom Heater, Varilla 1.02, Electric Bathroom Heater,
Bathroom Heater, Heater
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>