Caution!
Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires!
Avoid looking directly into
the light source!
Wear protective glasses and other PPE (personal protective equipment) when
working on or near the fixture.
Always make sure you are
connecting this product to the proper voltage in accordance with the
specifications in this manual or on the product’s specification label. Make
sure it is grounded when using it!
Unplug mains lead before opening the housing!
Make sure that the power cord is never crimped or damaged by sharp edges.
Check the fixture and the power cord from time to time.
Make sure to replace the fuse with another of the same type and rating.
For your own safety, please read this user manual carefully before you initial start-up. Follow operating safety precautions and pay attention to warning signs methods and equipment on the user manual.
Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for a cool-down period of at least 10 minutes before handling or transporting the device.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
Introduction
Thank you for having chosen FOS LEKO TW IP65. You will see you acquired a powerful and versatile device.
Unpack your item. Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
Safety instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers.
Installation
Read ‘Safety information’ before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location
with adequate ventilation.
Ensure that none of the fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at
any angle. Ensure that the surface and all fasteners used can support at least
10 times the weight of all fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any
orientation. When installing the fixture hanging vertically down, you can use
an open-type clamp such as a G-clamp. When installing in any other
orientation, you must use a half-coupler clamp that completely encircles the
truss chord.
To clamp the fixture to a truss:
- Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it.
- Block access under the work area.
- Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket. The bolt used must be M8. It must pass through both mounting bracket legs and be fastened with a self-locking nut.
- Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp securely.
- Secure the fixture with a safety cable as directed below
Securing with a safety cable
Secure the fixture with a safety cable (or other secondary attachment) that is
approved for the weight of the fixture so that the safety cable will hold the
fixture if a primary attachment fails.
Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the fixture unsecured if it separates from the bracket.
DMX-512 connection/connection between fixtures
Occupation of the XLR-connection:
- DMX OUT
1. Group **
**
2. Signal (-) **
**
3. Signal (+)
- DMX IN
1. Group
2. Signal (-)
3. Signal (+)
If you are using controllers with this occupation, you can connect the DMX- output of the controller directly with the DMX input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-
input of the next fixture. Always connect one output with the input of the
next fixture until all fixtures are connected.
DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an
electrically noisy environment, such as in a discotheque, it is recommended to
use a DMX terminator. This helps in preventing corruption of the digital
control signal by electrical noise. The DMX terminator is simply an XLR plug
with a 120 resistor connected between pins 2 and 3, which is then plugged into
the output XLR socket of the last fixture in the chain.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Power connection
Power Requirements
The FOS LEKO TW IP65 luminaire operates on 100 to 240 volts AC (+/- 10%, auto-
ranging). The luminaire contains an auto-ranging power supply.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color | Connection | International |
---|---|---|
Brown | Live | L |
Blue | Neutral | N |
Yellow/green | Earth(Ground) |
Operation
The FOS LEKO TW IP65 can operate in three different modes. In each mode you can run the fixture as a stand alone fixture or in a master/slave configuration. This next section will detail the differences in the operating modes.
Addressing
All fixtures should be given a DMX starting address when using a DMX signal,
so that the correct fixture responds to the correct control signals. This
digital starting address is the channel number from which the fixture starts
to listen to the digital control information sent out from the DMX controller.
The allocation of this starting address is achieved by setting the correct
number on the display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually.
If you set the same address, all the units will start to listen to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simultaneously.
If you set a different address, each unit will start to listen to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected fixture.
In the case of the FOS LEKO TW IP65 , which is 1/2/3/5 channels fixture. If you set, for example, the address in the 2 channel mode to channel 2, the device will use the channel 2 to channel 3 for control.
Note: After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is data received at the DMX input, the dot in the display will flash.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the
dimmer and strobe. A DMX controller allows you to create unique programs
tailored to your individual needs
Zoom
This function allows you to adjust the beam width of the fixture.
Step 1: Loosen the zoom buttons on the side of the device.
Step 2: Adjust the zoom by sliding the zoom knob forward or backward.
Step 3: Adjust the focus by sliding the focus knob forward or backward.
Step 4: Tighten the zoom and focus buttons.
Control Menu Map
MENU | SUB MENU | OPERATION |
---|---|---|
A001 | 001-512 | DMX address setting |
CHnL | 1/2/3/5 CH | Channel Mode |
dinn | 000 – 255 | Master dimmer 0 – 100% |
Strb | S.00 – S.20 | Strobe, speed increasing |
uL– | u.000 – u.255 | WW dimmer, 0 – 100% |
cL– | c.000 – c.255 | CW dimmer, 0 – 100% |
nodE | nod.0 | Dimmer speed 0 (no delay) |
nod.1 | Dimmer speed 1 | |
nod.2 | Dimmer speed 2 | |
nod.3 | Dimmer speed 3 | |
nod.4 | Dimmer speed 4 (slowest speed) | |
tEnP | t— | Fixture temperature |
UErn | Firmware version | |
rSEt | Reset | |
PnnF | 0.6F/1.2F/2.0F/4.0F/12F/24F | PWM frequency adjustment(KHz) |
DMX Protocol
1 Channel Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
2 Channel Mode | Function | Function Control |
--- | --- | --- |
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Strobe | 000-255: Strobe with speed increasing |
3 Channel Mode | Function | Function Control |
--- | --- | --- |
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Warm white | 000-255: WW 0-100% dimmer |
CH3 | Cold white | 000-255: CW 0-100% dimmer |
5 Channel Mode | Function | Function Control |
--- | --- | --- |
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Warm white | 000-255: WW 0-100% dimmer |
CH3 | Cold white | 000-255: CW 0-100% dimmer |
5 Channel Mode | Function | Function Control |
--- | --- | --- |
CH4 | Color temperature | 000-010: No function |
011-255: Color temperature WW – CW
CH5| Strobe| 000-255: Strobe with speed increasing
Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure compressed air.
- Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water.
- Check that the fixture is dry before reapplying power.
Technical specifications
Model: FOS LEKO TW IP65
Power supply: AC100-240V, 50/60Hz
Light source: 60W WW + 60W CW COB LED
Color temperature: 2700K – 6000K
Color Rendition: Avg. CRI 92
Zoom range: 15° – 30°
Power connection: IP rated power in
Signal connection: 3-pin XLR in & out
DMX channels: 1/2/3/5
Control mode: DMX, RDM
Housing: Color black, die-casting aluminum
Size(barn door excluded): 344 x 164 x 276mm
N.W. : 3 kg
Accessories(incl.): Power cable, gel frame, Y split DMX cable
Environment: IP65
Please note: All information is subject to change without prior notice. 11.08.2023