FOS technologies L006049 FOS Ultra Par LED PAR User Manual
- June 4, 2024
- FOS technologies
Table of Contents
FOS technologies L006049 FOS Ultra Par LED PAR User Manual
Safety Instruction
Please read this manual carefully, which includes important information about installation, using, and maintenance.
-
Please keep this manual as a future reference, if you sell the product to other users, make sure they have access to this manual as well.
-
Before using the lighting, please check carefully to make sure that there is no damage caused by transportation. If yes, please do not use and contact the dealer for the first time.
-
The lighting is only suitable for indoor to dry environment.
-
The installation and operation of lights should be carried out by professionals.
-
Use safety harness when fixing equipment.
-
The equipment must be installed in a well-ventilated area, at least 50 cm from the adjacent plane.
-
Make sure the ventilation holes are unobstructed to avoid overheating when the lightings are working.
-
Ensure that the power supply voltage is in line with the requirement of the equipment before operation.
-
Please earth the conductive body in case of electric shock.
-
Please do not use the light in more than 40 đ environment.
-
The shortest distance between all exterior surface and combustible materials is 2.5m.
-
It is forbidden to connect the lighting directly to the dimmer.
-
A small amount of smoke or peculiar smell may occur during the work of the new lighting, which will disappear after a few minutes.
-
Do not place combustible materials near the lighting when it is working, in case of fire danger.
-
Please check whether the power line is broken before turning on the lighting, please replace it immediately if there is any damage.
-
Lightings runtime surface temperature of 60 đ, please do not touch with bare hands.
-
Avoid long time to turn on lighting, so as not to shorten the life of lighting.
-
Avoid the metal and other conductive body into the interior of the lighting, so as to avoid electric shock or fire. If any foreign body enters the lighting, please cut off the power immediately.
-
Avoid operation in dirty and dusty environment, and regularly clean and maintain the lighting.
-
Children are not allowed to contact/operate lighting.
-
Do not touch the wire when the lighting is working in case of electric shock.
-
Avoid winding of power cord and other wire.
-
Please use the same model when replacing the fuse.
-
If there is a serious malfunction, please stop using it immediately.
-
Do not open the lighting again.
-
Please replace the lighting housing and lens when there is obvious damage.
-
The interior of the lighting is not available.
-
Please do not open the shell of the lighting without authorization.
-
If necessary, please contact the nearest authorized service center.
-
Please cut off the power when the lightings are not used or repaired for a long time.
-
Please use the original packing material for re-shipment.
-
To avoid fire or electric shock, do not expose the lighting to rain or wet areas.
-
Please do not look directly when the lighting is working.
-
The product may emit harmful optical radiation.
Warning:
- Do not expose the lighting to rain or humidity in order to prevent or reduce the danger of electric shock and fire.
- Shut off for 5 minutes.
- The lighting housing, when the lens has obvious damage, please replace it in time.
If AC 230V~50Hz power supply is used, do not connect more than 5 lamps in
series, please use another power supply to provide power for the next set of 5
lamp sets;
If AC 120V~60Hz power supply is used, do not connect more than 3 lamps in
series. Please use another power source to provide power for the next set of 3
lamp
Attention:
There is no spare parts inside the lamp, please do not open the shell
without authorization. Please contact the nearest technical service center if
necessary
Installation:
The lightings should be screwed to the bracket. Make sure the installation
is strong enough to prevent flicking and sliding at run time. Also make sure
the fixtures are stable and support the weight of more than 10 times the
equipment. At the same time, when the installation of the equipment, can use
under 12 times the product of the weight of the safety rope.
Equipment must be installed by professionals. The lighting is to be installed
on the human body, and there will be no passers-by or seats.
Technical specifications
- POWER SUPPLY: AC100–²40V,50HZ–60HZ
- POWER CONSUMPTION: 300W
- LIGHT SOURCE: 7×40W 4 in 1 RGBW Luminus LED
- CONTROL MODE: DMX51²ǃRDMǃMaster/SlaveǃAuto
- STROBE: 1–²5/S Electronic strobe
- DIMMER: 0–100% linearly adjustable
- BEAM ANGLE: 5˚– 45˚
- DMX CHANNELS: 11 CH
- DISPLAY: OLED DISPLAY
- PROTECTION RATE: IP65
- N.W.: 8.0 Kg
- DIMENSION SIZE: ²96ײ²0×436 mm
- PACKING SIZE: ²75ײ75×550 mm
Feature: Unique structure design, focus more smooth;Double hanger
design, can be placed on ground for use, a variety of installation schemes;
Multiple built–in programs, RGBW can mi× more wonderful colors; Built–in RDM,
easy to operate;Perfect dimming, built–in 4 dimming curve optional;Optical
angle adjustable, more diversified applications, no flicker output, die–cast
body, waterproof grade IP65.
How to set the lighting
Control Panel
- LCD: Displays menu options and selected features;
- Button:
** MENU| Select Function
---|---
DOWN| Select the next menu option
UP| Select the previous menu option
ENTER**| Confirm the selected function - POWERCON Input: connect lamp to supply power˗
- POWERCON Output: connect the next lamp and provide power;
- DMX Input: input DMX signal using 3-core XLR signal line;
- DMX Output: connect the next lamp with the 3-core XLR signal line and output the DMX signal;
Main Function
To select a preset feature, press the MENU button to select the MENU option you want. Press ENTER button to ENTER the selected function, the display screen will blink, then use the UP/DOWN button to select the desired function, press ENTER button to confirm. To return to the main MENU, press the MENU button
The main functions are shown below
No | English Display | Descriptions |
---|---|---|
1 | **** DMX Addr | 001 |
2 | Key_ADJ | R-Dim 000-255 |
G-Dim 000-255 | Manual adjustment of GREEN intensity 0-100% | |
B-Dim 000-255 | Manual adjustment of GREEN intensity 0-100% | |
W-Dim 000-255 | Manual adjustment of WHITE intensity 0-100% | |
3 | CCT | Brightness 000-255 |
CCT 000-255 | Manual adjustment of color temperature | |
4 | Focus | 000-255 |
5 | Test Mode | PROG 1/16 |
built-in program, and press OK to enter. Press the menu button to return to
the superior menu.
PROG-SPEED 1/16| Press “OK” to enter, press “up” and “down” to select the
built-in program speed, press “OK” to enter, and then press “Menu” to return
to the superior menu.
Auto/Sound| Press “OK” to enter, press “up” and “down” to select, press “OK”
to enter, then press “Menu” to return to the superior menu.
6| Setting| Dim mode 1/2/3/4| Press “OK” to enter, press “up” and “down” to
select,press “OK” to enter, then press “Menu” to return to the superior menu.
DMX Keep On/OFF| Press “OK” to enter, press “up” and “down” to select,press
“OK” to enter, then press “Menu” to return to the superior menu.
DMX Prio On/OFF| Press “OK” to enter, press “up” and “down” to select,press
“OK” to enter, then press “Menu” to return to the superior menu.
BackLight On/OFF| Press “OK” to enter, press “up” and “down” to select,press
“OK” to enter, then press “Menu” to return to the superior menu.
Language EN| Press “OK” to enter, press “up” and “down” to select,press “OK”
to enter, then press “Menu” to return to the superior menu.
7| system| System information
How to control the lighting
The lighting can be controlled in two ways as below:
- The Master/Slave Machine Built-in Function;
- DMX Controller.
No need to turn off the power of the lighting, and the new address code can be set immediately. Open the lighting, it began to receive DMX signal.
Master/Slave Built-in Function
String many sets of lightings, first walk in the lighting of 1, 2, 3 (host,
the host indicator, voice control indicator lights flashing, signal input
connectionless), will control the other lamps and lanterns (vice machine,
machine signal connection indicator) and the host with step effect
Universal DMX Controller
When using the general DMX control controller to control the lighting, please
set the starting address (1-512) for the light to receive the DMX letter
number.
Press MENU button up to show Address, Press ENTER button, to show flashing;
Use UP/DOWN button to select address code; Press ENTER to save or not save and
return to the last menu; Please click the MENU button to return the Main Menu.
If you want to use this function, please refer to the DMX512 address of the
first 4 lighting in the diagram below:
11CHSMode: 001, 012, 023, 034 ……
DMX512 Channels
After power on, connect to the console. When the DMX512 console signal is not received, an “X” appears behind the DMX ADDR menu. When the DMX512 console signal is received, the “X” behind the DMX ADDR menu will automatically disappear, and then the control console signal will be controlled. In the address code state, if there is no access console after multi-machine connection, the master-slave online function can be realized to operate one of the devices, while the rest devices in the address state follow the host to run programs synchronously. DMX512 signal must be cut off when the master- slave is online.
11 Channel Mode
No. | Function | Descriptions |
---|---|---|
CH1 | Zoom | 0-255 Zoom 0-100% |
CH2 | Dimmer | 0-255 Master dimmer 0-100% |
CH3 | Strobe | 0-255 Strobe from slow to fast |
CH4 | Red dimmer | 0-255 Red intensity 0-100% |
CH5 | Green dimmer | 0-255 Green intensity 0-100% |
CH6 | Blue dimmer | 0-255 Blue intensity 0-100% |
CH7 | White dimmer | 0-255 White intensity 0-100% |
CH8 | Preset colors | 0-255 Preset colors |
CH9 | Programs | 0-020 No function |
21-255 Built-in programs
CH10| Program speed| 0-255 speed from fast to slow
CH11| Reset| 194-255 reset
DMX512 Connection
In order to reduce the signal error and avoid signal transmission problems or signal interference, a 120ohm 1/4W resistor can be added between the pin2 and pin3 of DMX connection of the last lighting
- Connect the lighting with the XLR signal line, one end receives the outlet of the light, and the the rend receives the input port of the next light. XLR signal lines can only be used in series, not in parallel. DMX512 signal transmission is very fast. The signal line is damaged, the welding place is not secure, the contact is not good, it will affect the signal transmission, causing the system to close.
- When a unit of power supply circuit, DMX output and input is by-pass connection, so that can continue to maintain the DMX line connected.
- On the last light, the DMX wire needs an amplifier. Welding a 120 – ohm quarter w resistor between pni2 and responsible, within XLR plugs into 3 – pin and insert it in the end of a light DMX.
- Each light, want to have an address to receive information from the console, range between 0-512 usually 0 and 1 and 1equal).
- The 3-core XLR connector is more common than the 5-core XLR.
3 core XLR: PIN 1: GND, PIN 2: negative signal, PIN 3: positive signal.
5 core XLR: PIN 1: GND, PIN 2: negative signal, PIN 3: positive signal ,
Pin4/5:unused
Fault Handling
Here are some of the problems that are common in working and some
Suggestions for breaking down:
A. Lighting does not work, no lights.
- Check the power contact condition and whether the fuse is in good condition.
- Detect the voltage.
B. Out of Control by DMX
- The DMX indicator must be on. If not, check the DMX signal connector and signal line to see if the connection is correct.
- If the DMX indicator is on, but there is no response to channel control, and check the address code is set correctly.
- If the DMX signal transmission is intermittent, to check if the Canon is in good connection with the signal line.
- Try it again with another controller.
- Check whether the DMX signal line is too close to the high voltage line, which can damage or interfere with the signal circuit.
C. Out of control by Sound
- Make sure the light does not receive DMX signal.
- Check if the microphone for damage.
D. One certain channel does not work
- The drive line may be damaged or loos
Cleaning and maintenance
Lighting must be cleaned regularly so that the lighting effect is better. The cleaning frequency depends on the environment. Wet, smoggy, dirtier environments tend to dust the lenses.
- Use a soft linen and a special glass cleaner;
- Carefully wipe the cadres.
- Clean the exterior of the light once every 20 days at least once every 30 days or 60 days.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>