FOS technologies L004884 FOS Beam 150 Pro Moving Lights User Manual

June 4, 2024
FOS technologies

FOS technologies L004884 FOS Beam 150 Pro Moving Lights

Safety instructions

Thank you for choosing our FOS Beam 150 Pro. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.

Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.Please consider that damages caused by manual modifications to the device are not subject to warranty. During the operation the housing becomes hot). Allow the fixture to cool approximately 20 minutes prior to manipulate with it. Make sure that the available voltage is not higher than stated on the rear panel.
WARNING!
This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use or before cleaning or servicing the fixture. Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power-cord from time to time. Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power-cord by the plug. Never pull out the plug by tugging the power cord. This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth. The electric connection, repairs and servicing must be carried out by a qualified employee.

  • Do not connect this device to a dimmer pack.
  • Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
  • During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
  • Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
  • For replacement use lamps and fuses of same type and rating only.

11

|

9

|  | Speed pan/tile
---|---|---|---
0..225| max to min speed
226..235| blackout by movement
236..245| blackout by all wheel changing
246..255| no function

12

|

10

|  | Special function
0..19| No function
20..29| No function
30..39| No function
40..79| No function
80..84| All Motor reset
85..87| Scan motor reset
88..90| Colors motor reset
91..93| Gobo motor reset
94..96| no function
97..99| Other motor reset
100..119| Internal program 1
120..139| Internal program 2
140..159| Internal program 3
160..179| Internal program 4
180..199| Internal program 5
200..219| Internal program 6
220..239| Internal program 7
240..255| Internal Sound program 1

10

6

|

4

| 65..69| gobo 13
---|---|---|---
70..74| gobo 14
75..79| gobo 15
80..84| gobo 16
85..89| gobo 17
90..97| Gobo 1 shake slow to fast
98..105| Gobo 2 shake slow to fast
106..113| Gobo 3 shake slow to fast
114..121| Gobo 4 shake slow to fast
122..129| Gobo 5 shake slow to fast
130..137| Gobo 6 shake slow to fast
138..145| Gobo 7 shake slow to fast
146..153| Gobo 8 shake slow to fast
154..161| Gobo 9 shake slow to fast
162..169| Gobo 10 shake slow to fast
170..177| Gobo 11 shake slow to fast
178..185| Gobo 12 shake slow to fast
186..193| Gobo 13 shake slow to fast
194..201| Gobo 14 shake slow to fast
202..209| Gobo 15 shake slow to fast
210..217| Gobo 16 shake slow to fast
218..225| Gobo 17 shake slow to fast
226..255| Rot. gobo wheel cont. rotation slow to fast

7

|

5

|  | Shutter
0..31| Shutter closed
32..63| shutter open
64..95| Strobe effect slow to fast
96..127| shutter open
128..159| Pulse-effect in sequences slow to fast
160..191| shutter open
192..223| Random strobe effect slow to fast
224..255| shutter open
8| 6|  | Dimmer
0..255| Dimmer 0%…100%
9| 7|  | Focus
0..255| In(near) to out(far)

10

|

8

|  | Rrotating prism
0..5| Prism swing out(hole)
6..127| Prism swing in
128..189| Prism Forwards rotation from fast to slow
190..193| Prism rotation stop
194..255| Prism Backwards rotation from slow to fast

UNPACKING

FOS Beam 150 Pro adopts a 150W white LED lamp which features high brightness and stability. Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation. And please check whether the following items are included inside the box:

FOS Beam 150 Pro is made of a new type of high temperature strength of engineering plastics and cast aluminum casing with nice outlook . The fixture is designed and manufactured strictly following CE standards, complying with international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live per formances, theater, studio, nightclubs and discos. This manual covers the important information on installation and applications. Meanwhile, please keep this manual well for future needs.

TECHNICAL INFORMATION

  • SPECIFICATIONS: 1*150W white LED lamp, 7500K 50000 hours life span
  • Input Voltage:AC90-260V 50/60Hz
  • Power Consumption: 142W
  • Control Signal:DMX512, master-slave and sound activated or auto operation (7 built-in programs) Control Channel: 12/10 DMX channels USITT
  • DMX-512 Dimensions:362(D)177(W)362(H)mm
  • Packing Dimensions:360(D)250(W)450(H)mm Net Weight:7.1kgs
  • Gross Weight: 9.3kgs
  • FEATURES: 2.5m-15m electric focus low power consumption 0-100% Linear LED dimmer 25T/sec high speed LED shutter/strobe effect with variable speed
  • Preset variable/random strobe and dimming pulse effect 1.8’TFT LCD display (160*128pix)
  • Powercon connector IN 3-Pin XLR connectors IN/OUT
  • IP20 protection rating 55dB at 3’dB rating
  • 1*Hanging kit
  • 1* Safety attachment point

MOVEMENT:

  • 8/16 bit smooth and precise resolution for PAN/TILT movement
  • 360°/540°/630° PAN and 90°/180°/270° TILT movement

DMX PROTOCOL

Mode/Channel Value Function
16b 8b  
1 1  
0..255 PAN Movement
2    
0..255 Fine control of Pan movement
3 2  
0..255 Tilt Movement
4    
0..255 Fine control of Tilt movement







5

| ****







3

|  | Color wheel
0..7| Open / white
8..15| Color 1
16..23| Color 2
24..31| Color 3
32..39| Color 4
40..47| Color 5
48..55| Color 6
56..63| Color 7
64..71| Color 8
72..79| Color 9
80..87| Color 10
88..95| Color 11
96..103| Color 12
104..111| Color 13
112..127| Color 14
128..189| Forwards rainbow effect from fast to slow
190-193| Color rotation stop
194..255| Backwards rainbow effect from slow to fast






6

| ****





4

|  | Gobo wheel 1
0..4| Open
5..9| gobo 1
10..14| gobo 2
15..19| gobo 3
20..24| gobo 4
25..29| gobo 5
30..34| gobo 6
35..39| gobo 7
40..44| gobo 8
45..49| gobo 9
50..54| gobo 10
55..59| gobo 11
60..64| gobo 12

DMX

(Function Mode)

| Dmx Address| A001~AXXX| DMX address setting
---|---|---|---
Channel Mode| CH12 MODE| Standard mode
CH10 MODE| Vector mode
Auto Run| Program1~9 Master| /Alone| Auto run
Music Run| Program1~9 Master| /Alone| Sound Control

SET

(Fixture Set)

| Reset Default| Yes/No| Reset Default
Signal Set| Wire DMX| Wire DMX
Reverse Pan| (On/Off)| Reverse Pan
Reverse Tilt| (On/Off)| Reverse Tilt
Select Pan| 630°/540°/360°| Pan Degree,default is 540°
Select Tilt| 270°/180°/90°| Tilt Degree,default is 270°
Mic Sensitivity| 0~99%| MIC Sensitivity Setting
OFF Signal Mode| (On/Off)| OFF at original status and ON at reset status when no DMX signal

Manu

(Manual)

| Reset| Total Reset| Total Reset
Scan Reset| Scan Reset
Color Reset| Color Reset
Gobo Reset| Gobo Reset
Others Reset| The Others Reset
Channel| PAN=XXX……| Channel Control
ADV

(Advanced)

(Access Code 088)

| Calibration| PAN=XXX……| Calibration

PHOTO METRICS DIAGRAM

OPERATION INSTRUCTIONS

  • FOS Beam 150 Pro is for beam effect for on-site decoration purpose.
  • Don’t turn on the fixture if it’s been through severe temperature difference like after transportation because it might damage the light due to the environment changes. So make sure to operate the fixture until it is in normal temperature.
  • This light should be keep away from strong shaking during any transportation or movement.
  • Don’t pull up the light by only the head, or it might cause damages to the mechanical parts.
  • Don’t expose the fixture in overheat, moisture or environment with too much dust when installing it. And don’t lay any power cables on the floor. Or it might cause electronic shock to the people.
  • Make sure the installation place is in good safety condition before installing the fixture.
  • Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.
  • Make sure the lens are in good condition.It’s recommended to replace the units if there are any damages or severe scratch.
  • Make sure the fixture is operated by qualified personnel who knows the fixture before using.
  • Keep the original packages if any second shipment is needed.
  • Don’t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies.
  • It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation, like shock short circuit, electronic shock , lamp broke, etc.

Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personnel. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable. Never stand directly below the device when mounting, removing, or servicing the fixture. from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at least 0.5m (1.5 f t) away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.

Mounting points:
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.

Clamp Mounting:
FOS Beam 150 Pro provides a unique mounting bracket assembly that integrates the bottom of the base, and the safety cable rigging point in one unit (see the illustration below). When mounting this fixture to truss be sure to secure an appropriately rated clamp to the included omega bracket using a M10 screw fitted through the center hole of the “Hanging Kit”. As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly .

CONTROL CONNECTION

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below. DMX-512 connection with DMX terminator. For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 3 resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain. Please see illustrations below.

Maintenance and cleaning

It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol or solvents be used!The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the light-output very quickly. The cooling-fans should be cleaned monthly. The interior of the fixture should be cleaned at least annually using a vacuum- cleaner or an air-jet. Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner. Important! Check the air filters periodically and clean before they become clogged! Clean two air filters placed in the fixture’s covers and two in the fixture base. Use a vacuum cleaner, compressed air or you can wash them and put back dry. After replacing the air filters, reset the elapsed time counter in the menu “Information” (Information—>Air Filters—>Elapsed Time). Replacing the fuse. Before replacing the fuse, unplug mains lead.

  1.  Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
  2.  Remove the old fuse from the fuse holder.
  3.  Install the new fuse in the fuse holder (only the same type and rating).
  4.  Replace the fuseholder in the housing and fix it.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FOS technologies User Manuals

Related Manuals