  1. Place the UPS on its top and remove the retaining screw (figure 1).
  2. Slide the battery compartment cover completely off of the unit (figure 2).
  3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement battery by connecting the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. (figure 3)
  4. Slide the battery compartment cover over the battery and tighten the retaining screw.
  5. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.

MODEL : CP850AVRLCD, CP1000AVRLCD

CyberPower CP600LCD Compatible Replacement Battery - Battery
Replacement

  1. Place the UPS on its side and locate the battery compartment cover on the bottom of the UPS. Remove the four (4) retaining screws and pull the battery compartment cover off the UPS (figure 1 & 2).
  2. Remove the battery from the compartment and disconnect the battery wires from the batteries. Install the replacement batteries by connectingthe red wire and black wire to the same color wires from the battery pack. Put the battery pack into the compartment (figure 3).
  3. Slide the battery compartment cover over the battery and tighten the retaining screw. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.

AVR Series

MODEL: CP900AVR, CP1200AVR, CP1500AVRT, CP1285AVRLCD, CP1350AVRLCD, CP1500AVRLCD

CyberPower CP600LCD Compatible Replacement Battery -
UPS

  1. Place the UPS on its side to locate and remove the front panel retaining screws from the bottom of the UPS.
  2. Slide the cover (front panel) towards the bottom of the UPS.
  3. Remove it from the unit.
  4. Disconnect the cable located at the top of the cover.
  5. Disconnect the battery wires from the batteries.
  6. Remove the batteries from the compartment.
  7. Install the replacement batteries by connecting the red and black wires to the same color wires from the battery pack. Put the battery pack back into the compartment.
  8. Replace the battery compartment cover and tighten the retaining screw.
    Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

Smart APP Intelligent LCD Series

MODEL : OR500LCDRM1U, OR700LCDRM1U, OR1000LCDRM1U,OR1500LCDRM1U

CyberPower CP600LCD Compatible Replacement Battery - LCD
Series

  1. Remove the right side front panel.
  2. Remove the three retaining screws for the cable protection cover and remove the cover.
  3. Disconnect the black and red cable.
  4. Remove the one retaining screw holding the battery pack in place.
  5. Remove the battery pack.
  6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL : OR1500LCDRM2U, OR2200LCDRM2U, OR1500LCDRTXL2U, OR2200LCDRTXL2U

CyberPower CP600LCD Compatible Replacement Battery - front
panel

  1. Remove the right side front panel.
  2. Remove the three retaining screws for the cable protection cover and remove the cover.
  3. Remove the two retaining screws from the cable connectors.
  4. Disconnect the black and red cable.
  5. Remove the four retaining screws holding the battery pack in place.
  6. Remove the battery pack.
  7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL: CPS1500AVR

CyberPower CP600LCD Compatible Replacement Battery - UPS
performs

  1. Remove the right side front panel.
  2. Remove the two retaining screws for the cable protection cover and remove the cover.
  3. Disconnect the black and red cable.
  4. Remove the four retaining screws holding the battery pack in place.
  5. Remove the battery pack.
  6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

Smart APP SINEWAVE Series

MODEL: PR750LCD

CyberPower CP600LCD Compatible Replacement Battery - SINEWAVE
Series

  1. Remove the front panel of the UPS.
  2. Pull out both round knobs and remove the battery compartment cover completely off of the unit.
  3. Remove the batteries from the compartment.
  4. Disconnect the battery wires from the batteries.
  5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack. Put the batteries back into the compartment.
  6. Re-install the battery compartment cover and push both round knobs back into place. Put the front panel back on the UPS.
  7. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.

MODEL: PR1000LCD

CyberPower CP600LCD Compatible Replacement Battery - AC
power

  1. Remove the front panel of the UPS.
  2. Remove two screws from the battery compartment cover and slide the cover completely off of the unit.
  3. Remove the batteries from the compartment. Disconnect the battery wires from the batteries.
  4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack.
  5. Put the batteries back into the compartment. Re-install the battery compartment cover and tighten the retaining screws. Put the front panel back on the UPS.
  6. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.

MODEL: PR1500LCD

CyberPower CP600LCD Compatible Replacement Battery - front panel of the
UPS

  1. Remove the front panel of the UPS.
  2. Remove two screws from the battery compartment cover and slide the cover completely off of the unit.
  3. Remove the batteries from the compartment. Disconnect the battery wires from the batteries.
  4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack.
  5. Put the batteries back into the compartment. Re-install the battery compartment cover and tighten the retaining screws. Put the front panel back on the UPS.
  6. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.

MODEL: PR2200LCD, PR3000LCD

CyberPower CP600LCD Compatible Replacement Battery - screws from the
battery

  1. Remove the front panel of the UPS and two screws from the battery compartment cover and slide the cover completely off of the unit.

  2. Pull out the battery pack on the outside from the compartment.
    Disconnect the battery connector from the batteries.

  3. Before removing the battery pack on the inside, unlock the cable tie and pull out the battery wires. Disconnect the battery connector from the batteries.

  4. Install the replacement battery pack on the inside by connecting the wire bundle connector (composed of one red wire and one black wire) to the connector from the battery pack. Lock the battery wires back with the cable tie.

  5. Install the replacement batteries on the outside by connecting the wire bundle connector (composed of one red wire and one black wire) to the connector from the battery pack. Put the battery pack on the outside back into the compartment.

  6. Re-install the battery compartment cover and tighten the retaining screws and put the front panel back on the UPS.

  7. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
    Note : The battery pack on the outside has a fuse, while the battery pack on the inside does not.

MODEL : PR750LCDRM1U, PR1000LCDRM1U

CyberPower CP600LCD Compatible Replacement Battery - side front
panel

  1. Remove the right side front panel.
  2. Remove the two retaining screws for the cable protection cover and remove the cover.
  3. Disconnect the black and red cable.
  4. Remove the one retaining screw holding the battery pack in place.
  5. Remove the battery pack.
  6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse sequence of the above steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL: PR1500SWRM2U, PR2200SWRM2U

CyberPower CP600LCD Compatible Replacement Battery - retaining
screws

  1. Remove the right side front panel.

  2. Remove the two retaining screws for the cable protection cover and
    remove the cover.

  3. Disconnect the black and red cable.

  4. Remove the four retaining screws holding the battery pack in place.

  5. Remove the battery pack.

  6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL: PR1000LCDRT2U, PR1000LCDRTXL2U, PR1500LCDRT2U, PR2200LCDRT2U, PR3000SWRM2U

CyberPower CP600LCD Compatible Replacement Battery - right side front
pane

  1. Remove the right side front panel.
  2. Remove the three retaining screws for the cable protection cover and remove the cover.
  3.  Remove the two retaining screws from the cable connectors.
  4. Disconnect the black and red cable.
  5. Remove the four retaining screws holding the battery pack in place.
  6. Remove the battery pack.
  7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL: PR1000LCDRTXL2Ua, PR1500LCDRTXL2U, PR2200LCDRTXL2U, PR3000LCDRT2U, PR3000LCDRTXL2U

CyberPower CP600LCD Compatible Replacement Battery - front panel
from

  1. Remove the six retaining screws, and remove the front panel from the UPS.
  2. Remove the two retaining screws for the cable protection cover and remove the cover.
  3. Remove the two retaining screws from the cable connectors.
  4. Disconnect the black and red cable.
  5. Remove the three retaining screws holding the battery pack in place.
  6. Remove the battery pack.
  7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

PFC SINEWAVE Series

MODEL: PR5000LCDRTXL5U, PR6000LCDRTXL5U

CyberPower CP600LCD Compatible Replacement Battery - the front
panel

  1. Remove the front panel.
  2. Remove the two retaining screws of the cable protection cover and remove the cover.
  3. Pull the plastic sticker out slowly to remove the battery module.
  4. Put the new battery modules back into the compartment.
  5. Tighten the screws and replace the cable protection cover and the front panel.

MODEL: CP850PFCLCD, CP1000PFCLCD

CyberPower CP600LCD Compatible Replacement Battery - retaining
screw

  1. Turn the UPS on its side. Remove the retaining screw located on the bottom of the UPS.
  2. Slide the battery compartment cover completely off of the unit.
  3. Remove the batteries from the compartment.
  4. Disconnect the battery wires from the batteries.
  5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack. Put the batteries back into the compartment.
  6. Slide back the battery compartment cover and tighten the retaining screw. Recharge the UPS for 8-16 hours to fully charge the battery.

MODEL: CP1350PFCLCD

CyberPower CP600LCD Compatible Replacement Battery - front
panel

  1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the UPS.
  2. Slide the battery compartment cover (front panel) completely off of the unit.
  3. Remove the batteries from the compartment.
  4. Disconnect the battery wires from the batteries.
  5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack. Put the batteries back into the compartment.
  6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS for 8-16 hours to fully charge the battery.

MODEL: CP1500PFCLCD

CyberPower CP600LCD Compatible Replacement Battery - front
panel2

  1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the UPS.
  2. Slide the battery compartment cover (front panel) completely off of the unit.
  3. Remove the batteries from the compartment.
  4. Disconnect the battery wires from the batteries.
  5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack. Put the batteries back into the compartment.
  6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS for 8-16 hours to fully charge the battery.

FTTx Series

MODEL: OR1500PFCRT2U, OR2200PFCRT2U

CyberPower CP600LCD Compatible Replacement Battery - FTTx
Series

  1. Remove the right side front panel.
  2. Remove the three retaining screws for the cable protection cover and remove the cover.
  3. Remove the two retaining screws from the cable connectors.
  4. Disconnect the black and red cable.
  5. Remove the four retaining screws holding the battery pack in place.
  6. Remove the battery pack.
  7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.

MODEL: CSN27U12V-NA2, CSN27U12V-NA3, CSN27U12V-NA3-G, CSN27U12V-XL

CyberPower CP600LCD Compatible Replacement Battery - battery
cover

  1. Remove the battery cover.
  2. Disconnect battery cable connector to remove battery.
  3. Replace with new battery and re-connect the battery connector.
  4. Make sure battery is fixed properly in the compartment and close the battery cover.

MODEL : DTC36U12V-NA3-G

CyberPower CP600LCD Compatible Replacement Battery - battery
cover8

  1. Slide off the battery cover at the back of the DTC36U12V unit.
  2. Remove the battery from the enclosure.
  3. Disconnect both battery cable connectors.
  4. Install the new battery by connecting the red lead to the positive terminal and the black lead to the negative terminal.
  5. Slide the battery back into the normal operation.
  6. Replace battery cover to resume normal operation.

MODEL : CS24C12V2-E

CyberPower CP600LCD Compatible Replacement Battery - case
screw

  1. Remove the case screw.
  2. Open the battery cover.
  3. Loosen the battery strap.
  4. Disconnect battery cable connector to remove battery.
  5. Replace with new battery and re-connect the battery connector.
  6. Tighten the battery strip
  7. Close the battery cover and lock the case screw.

Cyber Power Systems, Inc.
www.cyberpower.com
For USA and Canada:
4241 12th Ave East, Suite 400
Shakopee, MN 55379
Toll-free:877-297-6937
For all other regions:
Please visit our website for
local contact information.

Documents / Resources

| CyberPower CP600LCD Compatible Replacement Battery [pdf] User Guide
CP600LCD Compatible Replacement Battery, CP600LCD, Compatible Replacement Battery, Replacement Battery, Battery
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals