LITHONIA LIGHTING CPHB ALO13 CPHB Linear LED Highbay Instruction Manual
- June 15, 2024
- LITHONIA LIGHTING
Table of Contents
INSTALLATION INSTRUCTIONS
CPHB Linear LED Highbay
Model Number
CPHB 12LM MVOLT
CPHB 15LM MVOLT
CPHB 18LM MVOLT
CPHB ALO13 MVOLT SWW9|
Model Number
CPHB 24LM MVOLT
CPHB 30LM MVOLT
CPHB ALO16 MVOLT SWW9
---|---
Optional Accessory
Surface Mount Bracket (THUN) | Pendant Monopoint Mount (PMP) |
---|
Protect yourself. Before installing, read these instructions carefully and
save them for future reference.
Date Installed:____
Acuity Brands Lighting, Inc.
One Lithonia Way, Conyers, GA 30012
www.acuitybrands.com
INSTALLATION FIGURES
FIXTURE PACKING LIST
Description | Quantity |
---|---|
1) Fixture Housing | 1 |
2) V-Hanger* . | 2 |
3) Chain* . | 2 |
4) Access Plate | 1 |
5) Access Plate Screw | 1 |
6) Wire Nuts* | 5 |
*Contained in Part Packs
Mounting Hardware Included
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW THESE SAFETY INSTRUCTIONS!
-
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
-
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
-
Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
-
For Residential installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electical code.
-
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
-
This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
-
It will occasionally be necessary to clean the outside of the refractor/ lens. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged
gaskets as necessary. -
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
-
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
-
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure, lens or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions including but not limited to: driver type, burning position, mounting locations/methods, replacement and recycling.
- Use only lamps that comply with ANSI standards.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/ lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat.
CAUTION RISK OF PRODUCT DAMAGE
-
Never connect components under load.
-
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
-
Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensor, timing device, or other related control devices. LED fixtures must be powered directly off a switched circuit.
-
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around the fixture.
Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or cooling. -
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
-
Only use fixture in its intended location.
-
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
-
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of unit.
-
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
-
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
-
Changes or modifications not expressly approved by Acuity Brands Lighting could void the authority to operate the equipment.
-
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with one of the following
Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference
that may cause undesired operation.
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
5-YEAR LIMITED WARRANTY
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com. Acuity Brands Lighting,
Inc. assumes no responsibilities for claims arising out of improper or
careless installation or handling of its products.
STEP-BY-STEP GUIDE
PREPARING THE FIXTURE FOR INSTALLATION
- Remove the parts pack and place it in a convenient location during installation. Check that all parts are included.
- Inspect the existing mounting location for damage before installing the new CPHB LED high bay in this location. Ensure mounting structure is properly sized to support the weight of the fixture.
- Remove the fixture from packaging and inspect for any damages. Handle fixture with care.
- After installation ensure no wires are pinched or caught outside the fixture housing.
INSTALLATION OF FIXTURE
- This fixture is designed to be Suspended using supplied V-Hangers and Chain or Surface mount installation with optional Surface Mount Bracket (THUN)- sold separately. Fixture may also be suspended using aircraft cable (sold separately).
- Provide suitable hardware that is both in accordance with local codes and is capable of supporting the full weight (7 lbs) of the fixture.
WARNING: Before wiring fixture to the power supply, turn off electricity
at fuse or circuit breaker box.
Suspended Installation- (Standard Mounting Method)
-
Locate provided Chains and V-Hangers. Attach Chain to each V-Hanger by feeding hanger through chain link.
-
Attach the V-Hanger to fixture by hooking the hanger through holes on the Fixture Housing- See Fig 2.
-
Secure the other end of the chain to structure using hardware rated for the load.
Make sure the wiring hangers are fully engaged into the side holes on the fixture housing. If using “S” hooks, make sure all loops are crimped closed if possible. Make sure wire hanger fits snuggly into holes of fixture housing.
Supply Wire connections- Make all supply wire connections in accordance with local electrical codes. -
Remove access plate screw- see Fig 3 and remove access plate from Fixture Housing (Input wires from Driver will be attached to the access plate).
-
Remove the necessary knockout(s) from Access Plate.
-
Secure incoming power supply to access plate with UL Listed connector. Use only UL listed supply wire (90°C or greater).
-
Make wire connections by connecting bare copper or green supply wire to green fixture wire. Connect black supply wire to black fixture wire and white supply wire to white fixture wire with UL Listed wire nuts (rated 90°C or greater). Purple and Pink leads are 0-10V (low voltage) dimming leads and each wire shall be capped when not being used.
-
Reinstall Access plate and secure with access plate screw.
CCT/ALO Selection – if equipped
Locate the CCT and ALO Switches on fixture housing (see Fig 6).
Default CCT is set at 4000K and default light output is set at 18000lm (ALO13)
and 30000lm (ALO16). Slide switch to select desired CCT and light output.
Surface Mount Installation- (Requires Surface Mount Bracket (THUN) – sold
separately
- Attach THUN Surface Mount bracket(s) to structure using hardware rated for the load.
- Support fixture while snapping Fixture Housing into THUN bracket(s). Ensure fixture is balanced.
- Install supplied nut and lock-washer. Properly tighten nut to secure THUN bracket around center channel- See Fig 4.
Pendant Monopoint Mount- (Requires Pendant Mount Bracket (PMP)- sold separately
- Attach PMP Hub to threaded pendant/conduit (not supplied) using 3/4”- 14 NPT THREAD HUB and Nut (supplied) as shown below.
- Support fixture while snapping Fixture Housing into PMP bracket. Ensure fixture is balanced.
- Install supplied nut and lock-washer. Properly tighten nut to secure PMP bracket around center channel- See Fig 5.
- Connect the supplied flex conduit between the access plate KO and PMP bracket KO. Connect input leads from fixture to one side of the conduit inside the fixture. Connect power supply wires to other side of the conduit in the PMP bracket. Make any necessary electrical connections. Supply wire must meet applicable electrical codes and be rated for a minimum of 90°C. Pink and purple leads are 0-10V (low voltage) dimming leads.
- Attach PMP Bracket sides with screws, one each- See Fig 5. Ensure wires are not pinched.
TROUBLE SHOOTING GUIDE
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem.
- Verify that fixture is wired properly.
- Verify that fixture is grounded correctly.
- The line voltage at the fixture is correct.
If further assistance is required, contact: Technical Support: (800) 705-SERV (7378) techsupport-industrial@acuitybrands.com
Limited Warranty and Limitation of Liability 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Terms and Conditions and Warranties | Acuity Brands
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>