INMOTION 310 Series Radio Control System User Manual

June 15, 2024
INMOTION

INMOTION 310 Series Radio Control System

FCC Rules

This device complies with part 15 of FCC Rules. Operation is subject to the followoing two conditions; (1) This device may not cause harmful interface, and (2) this device must accept any interference recieved, including interference that may cause undesired operation.

FCC ID: NCT048L10 IC: 2802A-048L10 CE 0678

WARRANTY

INMOTION Controls, Inc. guarantees that this product meets its published specification at the time of shipment from the factory. Under proper installation, it should work as expected. However, INMOTION Controls, Inc. does not guarantee that operation of the 310 Series Radio Control System is error-free or without interruption.

This equipment is warranted against defects in materials and workmanship for a period of one year from the date of shipment. During the warranty period, INMOTION Controls, Inc. is responsible for necessary repairs, as long as the product can be proved to be defective.

For warranty service or repair, this product must be returned to our factory. Customer is responsible for shipping charges to INMOTION Controls, Inc., while INMOTION Controls, Inc. will pay return shipping charges.

This warranty does NOT include consumable parts, such as joystick, batteries, fuses, buttons, and relays or damage from normal wear and tear. Furthermore, this warranty does NOT cover defects caused by misuse, neglect, accident, failure to follow instructions, improper installation, improper or insufficient maintenance, unauthorized modification, unsuitable operating environment, improper operation, ignorance of environmental specifications, improper software/interfacing, fire, or acts of God.

  • No other warranty is expressed or implied, except for the above mentioned
  • The remedies provided herein are the buyers’ sole and exclusive remedies.
  • INMOTION Controls, Inc. shall not be liable for any direct/indirect, special, incidental or consequential damages.

OPERATING PRECAUTIONS

ATTENTION

  • Due to the complex nature of the equipment, it is necessary to read the entire manual before installation.
  • Never dismantle equipment by any unauthorized personnel, or equipment may be damaged.
  • This Manual is for reference only; please call your distributor if further assistance is required.
  • This equipment has been strictly tested for quality before delivery from our factory. However, it must not be used in extremely dangerous situations, or where damage may result.
  • After operating, please shut off main power in Crane and the power to Receiver.
  • Transmitter should be placed safely when not in use to avoid accidental pressing of buttons.
  • The Crane should be equipped with main power Relay, Limit Switch and other required safety devices.
  • The GND (ground) of Receiver must be connected with metal part of Crane, or electrical shock will occur.
  • Do not use this device during electrical storm, or high electrical interference conditions.
  • Ensure Transmitter batteries are in good condition and power \for Receiver is normal.
  • Installation and maintenance should be done only while the Crane’s main power and Receiver’s power are OFF, to prevent electrical shock.
  • Contents of the Manual may be amended by the manufacturer without notice.

PRECAUTIONS

  • After Operating Series 310, please press EMO (Emergency Off) mushroom and turn the keyswich to the “Off” to shut off main power in the Crane & Receiver.
  • Stop operating when slow-response occurs due to insufficient
  • Transmitter power, beyond the remote control range, or severe interference.
  • Remove the batteries when the equipment won’t be used for a long period.
  • Operators must be in good health and have good judgment in regards to safety.
  • Remote Control operator must have adequate training and related license to avoid danger.
  • Series 310 Transmitter is durable and weather-resistant, but care should be taken not to subject it to severe impact or pressure.
  • Series 310 is suitable for use in diverse industrial environments, and adequate operating and maintenance will extend system’s life.
  • Check EMO mushroom and the other security functions of Series 310 system before daily operation.
  • Press EMO mushroom when malfunctions or abnormal conditions occur.
  • Operator must be familiar with the following Emergency Procedures before operating.

EMERGENCY PROCEDURES

In case of emergency, please follow the steps below and ask the distributor for service immediately.

  • Press EMO mushroom
  • Remove the batteries
  • Shut off the main power of the Crane and discontinue the operation

Contact the distributor to find out possible causes.

STANDARD ACCESSORIES

A standard and full set of Series 310 consists of:

  1.  Transmitter, 2 unit
    Standard Accessories

  2. Receiver, 1 unit

Note:
Inmotion Series 310 Shown. Models vary depending on options.

OPERATION

TRANSMITTER CONFIGURATION

Note:
Inmotion Series 310 Shown. Models vary depending on options.

RECEIVER CONFIGURATION

Note:
Inmotion Series 310 Shown. Models vary depending on options.

GENERAL OPERATION

  • Turn on the main power switch of the equipment (Crane).

  • Install 2 AA batteries in the battery box in the Transmitter.
    Make sure the polarity is correct.

  • Attach Transmitter battery door with screws.

  • Insert security key in the “OFF’ position.

  • Turn the keyswitch clockwise to the “ON” position, then continue to turn it to the “START” position to power-on.
    Note: LED indicator will flash red if proper procedures are not followed.

  • Operate Transmitter by pressing each pushbutton.

  • After operation, perform the following procedures in sequence:

    1. Press EMO mushroom
    2. Turn the keyswitch to the “OFF” position.
    3. Remove key and keep the transmitter in a safe place.
    4. Switch main power off to the equipment (Crane).
    5. Remove batteries if not used for a long period of time.
      Note: Transmitter has power indicating functions with LED display.
  • ←  Green Color” – The LED will flash green when battery power is sufficient.

  • → Red Color” – The LED will flash red when the power is low.

    • The operating distance will become shorter andintermittent when the batteries are low.
    • Replace with new batteries when battery poweris low.

! DO NOT USE RECHARGEABLE BATTERIES !

RECEIVER VOLTAGE SELECTION

There are two types of power voltages (DC and AC) available for the Series 310.

  1. DC Type:
    Input Voltage : 12~24 VDC
    Relay Contact: 10A-36 VDC

  2. AC Type:
    Three different AC transformers: 48/110/220V, 48/220/380V, 110/220/380V.
    Please disconnect the Receiver’s power, select the proper voltage, and plug in the connector. See picture below.

Note: Standard Systems are 48/110/220 VAC. If any others are required, please specify when ordering.

CHANGING THE FREQUENCY

It is easy to change the frequency of the Series 310 simply by replacing corresponding frequency crystals in both the Transmitter and the Receiver.

Instructions:

  1. Pry up the crystal with a flathead screwdriver.

  2. Remove the crystal from the system.

  3. Use needle nose pliers to straighten both pins of the new crystal.

  4. Insert the new crystal vertically into the PC board.

  5. Press the new crystal down into the socket.

ATTENTION:
The Transmitter frequency will be different from the Receiver frequency. For example, the transmitter crystals are labeled T01 thru T40 and receiver crystals are labeled R01 thru R40.

FREQUENCY CHART

Ch Freq. Mhz Ch Freq. Mhz Ch Freq. Mhz Ch Freq. Mhz
1 310.0325 11 312.7075 21 315.3825 31 318.0575
2 310.3000 12 312.9750 22 315.6500 32 318.3250
3 310.5675 13 313.2425 23 315.9175 33 318.5925
4 310.8350 14 313.5100 24 316.1850 34 318.8600
5 311.1025 15 313.7775 25 316.4525 35 319.1275
6 311.3700 16 314.0450 26 316.7200 36 319.3950
7 311.6375 17 314.3125 27 316.9875 37 319.6625
8 311.9050 18 314.5800 28 317.2550 38 319.9300
9 312.1725 19 314.8475 29 317.5225 39 320.1975
10 312.4400 20 315.1150 30 317.7900 40 320.4650

BATTERIES

Two AA size alkaline batteries are required for the Transmitter.

The LED will flash green when the battery power is sufficient.

The LED will flash red when the battery power is low.

  • The operating distance will become shorter and intermittent when the battery is low.
  • Replace with new battery when battery power is low.
    ! DO NOT USE RECHARGEABLE BATTERIES !

INSTALLATION NOTES

INMOTION 310
INMOTION 310 1/Both/2

Installation Notes

INMOTION 310
1/Both/2 Option

  1. System must be programmed for this option.
  2. Connect wire #17 to X1.
  3. Connect wire # 18 to relay coil of selector relay #1
  4. Connect wire # 19 to relay Coil of selector relay #2
    NOTE: INMOTION 310-3C & 310-T/H-C Similar.

INMOTION 310-3C

INMOTION 310-T/H-C

Installation Notes
Do You Have a Harch Environment?

Are Your Operators Tough on Transmitters?

Try Our Neoprene Rubber Boots

Documents / Resources

| INMOTION 310 Series Radio Control System [pdf] User Manual
310 Series Radio Control System, 310 Series, Radio Control System, Control System, System
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

INMOTION User Manuals

Related Manuals