INMOTION K200-HV Series Radio Remote Control Owner’s Manual
- May 15, 2024
- INMOTION
Table of Contents
INMOTION K200-HV Series Radio Remote Control
Product Information
Specifications
- Brand: Inmotion Controls, Inc.
- Model: K Series Transmitter
- Versions: 2, 4, 6, or 8 pushbuttons
- Features: 2-step pushbuttons
Product Usage Instructions
Chapter 1: Customer Information
Thank you for purchasing an Inmotion Controls, Inc. radio remote control.
Make sure to read all instructions carefully before mounting, installing, and
configuring the product. The manual provides general information on operating
the radio remote control transmitter.
FCC Part 15 Compliance
This device complies with Part 15 of the FCC Rules. It must not cause
harmful interference and must accept any interference received. Any
unauthorized changes or modifications could void your authority to operate the
equipment.
IC Statement
This device complies with Industry Canada license-exempt RSS standard(s).
It must not cause interference and must accept any interference that may
affect its operation.
Chapter 2: General Description
The K series transmitter is available in different versions with varying
pushbutton configurations. It also includes 2-step pushbuttons that can
control different functions such as movement speed.
Start/Horn Switch
The Start/Horn pushbutton on the left side of the transmitter serves two
functions: starting and activating the horn during operation.
Starting the Transmitter
- Turn to release the Emergency Off button.
- Press the START button to initiate operation.
Turning Off the Transmitter
To turn off the transmitter, fully press the Emergency Off button. This
action deactivates all relays and turns off the transmitter.
FAQ
Guarantee, Service, Repairs, and Maintenance
-
Q: What is covered by the guarantee/warranty?
A: The guarantee covers material, construction, and manufacturing defects. Inmotion Controls, Inc. may replace faulty products or parts during the warranty period. -
Q: What is not covered by the guarantee/warranty?
A: The guarantee does not cover normal wear and tear, consumable parts, unauthorized modifications, incorrect installation or use, condensation, and water damage. -
Q: Who should carry out repairs and maintenance?
A: Qualified personnel should conduct repairs and maintenance using spare parts from Inmotion Controls, Inc. Keep the product in a dry, clean place and ensure contacts and antennas are clean.
Guarantee, service, repairs and maintenance
Inmotion Controls, Inc. products are covered by a guarantee/warranty against material, construction and manufacturing defects. During the guarantee/warranty period, Inmotion may replace the product or faulty parts. Work under guarantee/warranty must be carried out by Inmotion Controls, Inc.
The following are NOT covered by the guarantee/ warranty:
- Faults resulting from normal wear and tear
- Parts of a consumable nature such as pushbuttons, relays, fuses etc.
- Products that have been subject to unauthorized modifications
- Faults resulting from incorrect installation and use
- Condensation and water damage
Maintenance:
- Repairs and maintenance must be carried out by qualified personnel.
- Use spare parts from Inmotion Controls, Inc. only.
- Contact your representative if you require service or other assistance.
- Keep the product in a dry, clean place.
- Keep contacts and antennas clean.
- Wipe off dust using a slightly damp, clean cloth.
Customer Information
Thank you for purchasing an Inmotion Controls, Inc. radio remote control.
READ ALL INSTRUCTIONS CAREFULLY BEFORE MOUNTING, INSTALLING AND CONFIGURATING
THE PRODUCT.
This manual includes general information concerning the operation of the radio
remote control transmitter.
General Information on Safety
- Persons under the influence of drugs and/or alcohol and/or other medicine that impairs their reaction may not assemble, disassemble, install, put into operation, repair or operate the product.
- All conversions and modifications of an installation/system must conform to the relevant safety requirements. Work on the electrical equipment must be performed only by qualified, authorized personnel and in accordance with the relevant safety requirements.
- In the event of malfunctioning, visible defects or irregularities, the product must be stopped, switched off and the relevant master switches must be switched off.
Symbols and Definitions for Warnings
Warning against hazardous situation
Warning against electrical voltage
FCC Part 15 (FCC ID: RN489896162JK01)
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
- You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
European Union Regulatory Notice
This device bearing the CE marking is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
This device complies with the following harmonized European standards.
Safety: EN 60950-1:2006+A11:2009+A1:2010+A12:2011
EMC: ETSI EN30 1489-1 V1.9.2 2001-09; ETSI EN 301 489-3 V1.4.1 2002-08
Radio: ETSI EN 300 220-1 v2.4.1: 2012; ETSI EN 300 220-2 v2.4.1: 2012
The following CE marking is valid for EU harmonized telecom products.
IC Statement (IC: 10821A-8989616201)
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
General Description
The K series transmitter comes in different versions, featuring 2, 4, 6, or 8 pushbuttons. The transmitter also features 2-step pushbuttons. Both steps of each pushbutton can operate different functions like controlling the speed of a movement, step 1: slow, step 2: fast.
Start/ Horn switch
The K series transmitter has a Start/Horn pushbutton on the left side.
The Start/Horn switch has 2 functions:
- Press to Start.
- Press for horn while operating.
Start the transmitter in operating mode
- Turn to release the Emergency Off button.
- Press the ”START” button.
Turning the transmitter off
Turn the transmitter off by completely pressing the Emergency Off button. The
transmitter turns off. All relays deactivate.
Changing the batteries:
BATTERY TYPE: 2 x 1.5V(LR6 AA)
Technical Data
Transmitter
Frequency Range | 433.0525~434.7775MHz |
---|---|
Modulation method | 4FSK |
Typical operating range | 300 feet |
Control system | PLL (Phase Lock Loop) |
Antenna impedance | 50 ohms |
Typical response time for commands | 50ms~100ms |
Power Supply | LR6 (AA) 1.5Volt x 2 |
Antenna | Internal |
Average power consumption | 16ma@3VDC (default setting) |
Radio-frequency power | <10dBm (default setting) |
Operating and storage temperature | -4°F ~ 131°F / -40°F ~ 149°F |
Protection rating | IP65 |
Dimensions | 7.63” x 2.25” x 2.00” (2-8 buttons) |
Weight (including battery) | Approx. 11.46 ounces |
Housing material | PA6 (30% Glass Filled) |
Receiver
WARNING: The receiver must NOT be opened by any other than a qualified installer. Make sure to turn the electricity off before opening the receiver.
Technical Data
Receiver
Frequency | 433.0525~434.7775MHz |
---|---|
Modulation Method | 4FSK |
Sensitivity | -112dBm@baud 1.2K bps |
Control System | PLL |
Antenna impedance | 50 ohms |
Typical response time for commands | 50mS ~ 100mS |
Power Supply | 12 ~ 24V AC/DC |
Antenna | Internal |
Standby power | 16mA @ 220VAC |
Operating and storage temperature | -4°F~131°F/-40°F~149°F |
Protection degree | IP 65 |
Dimensions | 5.59” x 5.55” x 2.30” |
Weigh | 1.76 Lbs. |
Housing material | PA6 (30% Glass Filled) |
WARNING: DO NOT FLUSH MOUNT THE RECEIVING ASSEMBLY. PLEASE MAINTAIN PROPER CLEARANCE AS SHOWN. PLEASE USE THE SUPPLIED MOUNT!
K200-HV Wiring Diagram
K400-HV Wiring Diagram
Receiver Dimensions (Not to scale)
Troubleshooting
Transmitter
Receiver
Should an error occur, the LED of the receiver will indicate the cause.
- invalid data (from a different transmitter) received.
Accessories
Pushbutton Protector
Waterproof Case
Lanyard
INMOTION Controls, Inc.
Website: www.inmotioncontrols.com
888-501-2220
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>