  • Product Name: CTACv-30 twin conductor heating cable
  • Voltage: 230V
  • Output: 195W – 3400W
  • Diameter: Not specified
  • Max Temperature: Not specified
  • Connection Cable: Not specified
  • Min Installation Temperature: Not specified
  • Conductor Insulation: Not specified
  • Overjacket: Not specified
  • Min Bending Radius: Not specified
  • Protection Class: Not specified
  • Warranty: Not specified

Product Usage Instructions

Step 1: Prepare the Installation Area

Make sure the installation area is clean, dry, and free from any debris. Ensure that the surface is suitable for the installation of the heating cable.

Step 2: Unroll the Heating Cable

Unroll the CTACv-30 twin conductor heating cable along the desired area where heating is required. Ensure that the cable is not twisted or kinked.

Step 3: Connect the Heating Cable

Connect one end of the heating cable to the power supply using the appropriate connection method. Follow the provided instructions or consult a qualified electrician for proper installation.

Step 4: Secure the Heating Cable

Secure the heating cable in place using adhesive tape or cable clips. Ensure that the cable is evenly spaced and properly secured to prevent any damage during use.

Step 5: Test the Heating Cable

Before covering or burying the heating cable, test the functionality by turning on the power supply. Monitor the heating cable for proper heating performance and ensure there are no issues or malfunctions.

Step 6: Cover or Bury the Heating Cable

Once the heating cable has been tested and verified to be working correctly, cover or bury it according to the specific installation requirements. Follow the instructions provided or consult a professional for guidance.

Step 7: Power On and Control

Connect the heating cable to a suitable thermostat or control system to regulate the temperature. Follow the instructions provided with the thermostat or control device for proper programming and operation.

Step 8: Maintenance and Safety

Regularly inspect the heating cable for any signs of damage or wear. Keep the area around the heating cable clean and free from any obstructions. Follow all safety guidelines and precautions mentioned in the user manual.

FAQ (Frequently Asked Questions)

What is the maximum temperature that the CTACv-30 heating cable can handle?

The maximum temperature for the CTACv-30 heating cable is not specified in the user manual. Please refer to the product specifications for more information or contact Comfort Heat Ltd. for assistance.

What is the warranty period for the CTACv-30 heating cable?

The warranty period for the CTACv-30 heating cable is not specified in the user manual. Please refer to the warranty information provided by Comfort Heat Ltd. or contact them directly for further details.

Can I install the heating cable myself or do I need professional assistance?

While it is possible to install the heating cable yourself, it is recommended to consult a qualified electrician for proper installation. They will ensure that the electrical connections and installation meet safety standards and regulations.

CTACV-30
twin conductor heating cable

CTACV-30 is a twin conductor heating cable of 30 W/m output, and it has double protection (M2), aluminium tape and tinned copper screen with memory, fluoropolymer insulation and polypropylene overjacket. The heating cable is UV resistant.
It is designed for roof ice and snow melting systems (roof gutters and downpipes) and ground frost protection of ground (ramps, driveways, entrances, car parks, pavements, bridges, stairs, etc.), and frozen soil in winter (construction sites).
Installation: It can be laid in roof gutters, downpipes, roof edges and into concrete or stone dust layer under tiles for frost protection of entrances, driveways, car parks, ramps, pavements and bridges. The cable can be laid directly on frozen soil whereby covering it with rock wool mats.

TECHNICAL DATA

  • Voltage 230 V
  • Output 30 W/m
  • Diameter 5,9 mm
  • Max temperature +80 °C
  • Connection cable 5 m
  • Min installation temperature +5 °C
  • Conductor insulation Fluoropolymer (FEP) + (XLPE)
  • Overjacket Polyvinyl chloride (PVC)
  • Min bending radius 8 diameters
  • Protection class IP67
  • Warranty 20 year

Product list

Type| Voltage (V)| Length (m)| Output (W)| Order No.
---|---|---|---|---
CTACV-30| 230| 7| 195| 82253505
 |  |  |  |
CTACV-30| 230| 14| 420| 82253515
 |  |  |  |
CTACV-30| 230| 22| 670| 82253525
 |  |  |  |
CTACV-30| 230| 32| 970| 82253535
 |  |  |  |
CTACV-30| 230| 44| 1300| 82253545
 |  |  |  |
CTACV-30| 230| 65| 1940| 82253555
 |  |  |  |
CTACV-30| 230| 96| 2800| 82253565

Comfort Heat Ltd. | Phone: + 370 5 2704596 | info@comfortheat.eu