MODEL: HM-AH001
ULTRASONIC COOL MIST HUMIDIFIER
User Manual
STATEMENT
Thank you for purchasing a Homech product that has been tested to meet our stringent quality standards. This product is covered with Homech product and labor warranty for 12 months from the date of its original purchase.
Please email us with your Order ID and problem or issue, we will respond within 24 hours.
Please read the User Manual thoroughly. Clean and maintain the product as instructed. If any abnormalities occur, please refer to the Troubleshooting Guide first.
This warranty is void if the defect is caused by accidental damage, misuse,
abuse, neglect, improper repair or alteration by unauthorized persons, or a
failure to follow operating instructions provided with the product including
adding essential oils directly into the tank and base.
This warranty does not apply to normal wear and tear or commercial use.
In no event shall liability exceed the purchase price paid by the purchaser of
the product.
Under no circumstances shall there be liability for any loss – direct,
indirect or incidental – or consequential damage arising out of, or in
connection with the use of the product.
SAFETY INSTRUCTIONS
The humidifier was made with safe and environmental protection materials, it has been certified and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons or damage to the product.
BEFORE USING THE HUMIDIFIER
- Please extend the cord and check any signs of damage. Do not use the humidifier if the cord has been damaged.
- DO NOT place this humidifier in wet environments.
Please always keep the humidifier out of reach of patients & children & pet.
- Please always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and level surface and keep it away from direct sunlight.
- Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances or wooden furniture.
- DO NOT place the unit on carpet, towel or wood surface, which will block the vent and may damage the unit.
- DO NOT place the humidifier near naked flames and heat sources, such as stove tops, ovens, radiators or computers.
WHEN USING THE HUMIDIFIER
- DO NOT plug the unit with wet hands.
- DO NOT direct the mist nozzle against the wall.
- DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury.
- DO NOT clean the unit while it is connected to a power source or while it is on.
- DO NOT move or tilt the humidifier while it is in operation.
- The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect from a power source by pulling the plug when not in use.
- Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and Maintenance instructions.
- DO NOT clean the humidifier right after turning it off if the humidifier has been diffusing warm mist. Allow the humidifier to completely cool down before cleaning.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier. Doing so will void your warranty.
PACKAGE CONTENTS
- 1 x Homech Humidifier (Model: HM-AH001)
- 1 x Cleaning Brush
- 1 x Dustproof Sponge
- 1 x Thank You Card
- 1 x User Manual
SPECIFICATIONS
Model
|
HM-AH001
---|---
Operating Voltage| AC100-120V 50 / 60Hz
Rated Power| Min: 15W
Max: 25W
Water Tank Capacity| 4.0L / 1.06Gal
Mist Output| Min: 60ml/h
Max: 300ml/h
Working Time on a Full Tank| 12-50h
Recommended Room Size| 20-40m2 / 215-430ft2
Noise| <27dB
Dimensions| 258 x 164 x 338mm / 10.2 x 6.5 x 13.3in
Net Weight| 1350g / 47.6oz
PRODUCT DIAGRAM
- Nozzle
- Handle
- Water Tank
- Water Level Window
- Base
- Power Cord
- Control Knob
- LED Indicator
- Muffler
- Tank Cap
- Water Inlet
- Air Outlet
- Water Reservoir
- Atomizer
- Water Floater
- Dustproof Sponge
- Air Inlet
OPERATIONS AND FUNCTIONS
Add water
- Turn the water tank upside down. Remove the tank cap and fill the tank with clean and cool water only.
- Attach the tank cap and place the tank back onto the base. Please make sure it fits together securely so that water can go from the tank to the reservoir.
- If tap water is too hard, it is recommended to use filtered or distilled water to avoid white dust. DO NOT use hot water.
- DO NOT add any essential oils or medicinal tablets into the water tank.
- DO NOT add water into the base or through nozzle.
- DO NOT move the humidifier while the water tank is full of water to avoid leakage or base overfilling.
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidifier is ready for
use.
- Rotate the control knob clockwise to the ON position. The white LED indicator will light up indicating the humidifier has been turned on to a minimum mist level.
- Keep rotating the control knob clockwise to increase the mist level.
- Rotate the control knob counterclockwise to the OFF position to turn off the humidifier. The LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
Low Water Protection: Auto Shut-off the Humidifier
When there is not enough water inside the water reservoir, the humidifier will
stop misting and the LED indicator will become red. It is designed for safety
to prevent the humidifier from possibly overheating and damaging the atomizer.
CLEANING AND MAINTENANCE
Caution
- DO NOT submerge the base in water.
- Make sure water does not enter the base through the air outlet, air inlet, or the control knob.
- DO NOT wash any part of this humidifier in dish washer which will damage the humidifier and void the warranty.
Daily Maintenance
Turn off the humidifier, unplug it from the power source. Drain water from the
tank, reservoir and base.
Weekly Maintenance
- To properly clean your humidifier, we recommend you to remove scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of bleach per gallon of water to avoid damaging your humidifier.
- Please make sure the sealing ring on the tank cap is installed properly after cleaning to avoid water leakage.
Scale Removal Instructions
- Turn off and unplug the humidifier.
- Remove the water tank from the base. Remove the tank cap. Make sure that the white sealing ring does not come off. Drain water from the water tank and base. Remove any accessories and set aside.
- Fill the water tank half full. Add in 1 teaspoon of undiluted distilled white vinegar. Attach the tank cap and shake for 15 seconds.
- Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen mineral buildup (scale) on the atomizer, water floater and the bottom of the water tank. Set still for 15-20 minutes.
- Uncap the tank cap and drain the solution. Wipe the atomizer and floater with a soft cloth to remove loosened mineral deposits.
- Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal) or bleach solution (for disinfecting, see below) is gone.
Disinfecting Instructions
- Follow steps 1-2 of the previous section on scale removal.
- Fill the water tank half full. Add in ½ tsp of bleach. Place the tank cap back on. Swish the solution around in tank. Place the tank on the base. The bleach solution will enter and disinfect the water reservoir as well as the other components. Set still for 15-20 minutes.
- Follow steps 4-6 of the previous section on scale removal to complete disinfecting the humidifier.
Clean the Dustproof Sponge
Clean the dustproof sponge (at the bottom of base) with water or detergent
once a month.
Put it back in place after cleaning.
End-Of-Season Care and Storage
- Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. Remove any accessories used with the humidifier and allow the humidifier and accessories to dry completely before storing.
- DO NOT store with water inside the base, water reservoir, or tank.
- Pack the unit safely and store in a cool, dry location.
TROUBLESHOOTING GUIDE
- If the information listed in the troubleshooting guide can’t solve your problem, please email us for help.
- Failure to keep this unit clean from mineral deposits may affect operation of this unit.
- Customer failure to follow these instructions may void the warranty.
Problem
| Possible Cause|
Solution
---|---|---
LED indicator is off| Unit not plugged in| Ensure unit is properly plugged in
No power from power outlet| Try another power outlet
Did not turn on the unit|
Check the Control Knob is turned to the ON position.
LED indicator stays red| No water in the water reservoir|
Ensure the © Spring is secured properly to the tank bottom allowing water to pass through to the base
© Water floater stuck|
Adjust the © water floater to a horizontal position and make sure it can rise up with water
The LED Indicator is white but no mist or little mist is produced| Not enough water inside the tank|
Refill and reinstall the water tank
---|---|---
Mist level is set too low| Adjust to maximum mist
Mineral buildup on the atomize|
Feel if any air comes out from the nozzle. If yes, then clean water scale on the atomizer as instructed
The base might be overfilled| Remove the tank, empty the base and place the
filled tank on the empty base
Tank leakage| Tank may be damaged|
Check for possible cracks in the tank, replace if necessary
Tank cap is not tightened securely| Tighten the tank cap
O Spring stuck|
Ensure the Q spring is properly secured to the tank bottom allowing water to pass through to the base.
0 Sealing ring was not installed on tank cap| Install the 0 sealing ring on the tank cap, please contact us if it is missing
Mist height is low, damping surrounding desk or floor. Condensation forms around humidifier or on windows and walls
| Mist level is set too high for the room size|
1. Check if the room is too humid and adjust to lower mist. 40%-60% works best
2. Open door and windows, or change to a larger room
Air inlet is blocked|
Humidifier should be placed on a hard flat surface,2 feet above the floor, 12 inches away from the wall. Point nozzle away from wall or window
Low indoor temperature leads to liquefaction| Raise the room temperature to
25°C / 77°F
Poor humidification| Mist level is set too low for the room size|
1. Adjust to maximum mist
2. Close door or windows to reduce air ventilation, or change to a smaller
room
---|---|---
Air inlet is blocked|
Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall
Low indoor temperature leads to liquefaction| Raise the room temperature to
25°C / 77°F
White dust appears or the black coating on the base flakes off| Tap water may
contain too much minerals| Replace with filtered or distilled water
Strange Odor| Clean the unit|
1. Clean the humidifier as instructed
2. Leave the empty and opened water tank in a cool place for 12 hours without
the tank cap attached
Strange water noise| Water is going down to the water reservoir| This is
normal while it is working
Humidifier is getting too hot| Unit works for too long| Power off and place in
a well-ventilated place for 10 minutes
WARRANTY
This product is covered with Homech product and labor warranty for 12 months from the date of its original purchase. You will be given a warranty extension to 18 months if the product is registered on our website (www.homech.net).
Any defective part will be, at the discretion of SUNVALLEYTEK INTERNATIONAL INC. , repaired or replaced at no charge if the appliance has not been tampered with and has been used according to these printed directions.
If any problems occur, please contact Homech support (support@homech.net) immediately to launch a warranty claim. Specify model number and your Amazon order number. Our Consumer Service Representative will respond within 1 business day, advise you how to correct the problem yourself, or instruct you on how to return the defective unit back to us for repair or replacement.
We can only provide after sales service for products that are sold by Homech or Homech authorized retailers and distributors. If you have purchased your unit from a different place, please contact your seller for return and warranty issues.
CONTACT / HOMECH CUSTOMER CARE
PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE. EMAIL HOMECH CUSTOMER CARE FOR PROBLEMS AND QUESTIONS. WE WILL RESPOND WITHIN 1 BUSINESS DAY.
E-mail: support@homech.net(US)
support.ca@homech.net(CA)
support.uk@homech.net(UK)
Website: www.homech.net
HM-AH001
Homech
www.homech.net
NORTH AMERICA
Email:
support@homech.net(US)
support.ca@homech.net(CA)
US Distributor: SUNVALLEYTEK INTERNATIONAL INC.
Address: 46724 Lakeview Blvd, Fremont, CA 94538
EUROPE
E-mail:
support.uk@homech.net(UK)
support.de@homech.net(DE)
support.fr@homech.net(FR)
support.es@homech.net(ES)
support.it@homech.net(IT)
EU Importer: ZBT International Trading GmbH, Halstenbeker
Weg 98C, 25462 Rellingen, Deutschland
MANUFACTURER
Shenzhen NearbyExpress Technology Development Co.,Ltd.
Address: 333 Bulong Road, Shenzhen, China, 518129
Made in China
Hometech Humidifier HM-AH001 User Manual – Download
[optimized]
Hometech Humidifier HM-AH001 User Manual – Download
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>