BROAN FG7S High Efficiency Upflow Horizontal and Downflow Gas Furnaces
Technical Specifications
- Product Name : FG7S (A and K Series) Gas Furnaces
- Type : High Efficiency Upflow/Horizontal and Downflow
- Induced Draft – 80+ AFUE Input
- Input Range : 45,000 – 126,000 Btuh
- Installation : Free standing in utility room, basement, or enclosed in an alcove or closet
- Design Certification : CSA for application in Canada and the United States
TECHNICAL SPECIFICATIONS
FG7S (A and K Series) High Efficiency Upflow/Horizontal and
Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
- The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
- This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- High static blowers: All models equipped with high static blowers.
- 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
- Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
- High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
- Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
- Blower Compartment: Insulated for ultra quiet operation.
- Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
GAS FURNACE COMPONENTS
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube (Downflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
DIMENSIONS
FG7SA 80+ High Efficiency Upflow/Horizontal Series
FG7SK 80+ High Efficiency Downflow Series
BLOWER PERFORMANCE – FG7SA
**Model Number| Heating Input (Btuh)| **
Motor Speed
| External Static Pressure (Inches Water Column)
---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise
| | High*| 1260| 26| 1205| 28| 1145| 29| 1080| 31| 1025| 33| 960| 35| 890|
37| 825| 40
SA045( )-23A
Bottom Return
| **** 45,000| Med-High
Med-Low**
| 955
825
| 35
40
| 950
800
| 35
42
| 940
760
| 35
44
| 935
730
| 36
46
| 925
690
| 36
48
| 860
650
| 39
51
| 800
600
| 42| 725
530
| 46
–| –
| | Low| 655| 51| 630| 53| 610| 55| 580| –| 550| –| 520| –| 480| –| 435| –
| | High*| 1350| 25| 1290| 26| 1225| 27| 1155| 29| 1100| 30| 1025| 33| 950|
35| 885| 38
SA045( )-23A
Side Return
| **** 45,000| Med-High
Med-Low**
| 1025
885
| 33
38
| 1015
855
| 33
39
| 1005
815
| 33
41
| 1000
780
| 33
43
| 990
740
| 34
45
| 920
695
| 36
48
| 855
640
| 39
52
| 775
565
| 43
–
| | Low| 700| 48| 675| 49| 655| 51| 620| –| 590| –| 555| –| 515| –| 465| –
| | High*| 1260| 32| 1205| 33| 1145| 35| 1080| 37| 1025| 39| 960| 42| 890| 45|
825| 48
SA054( )-23A
Bottom Return
| **** 54,000| Med-High
Med-Low**
| 955
825
| 42
48
| 950
800
| 42
50
| 940
760
| 43
53
| 935
730
| 43
55
| 925
690
| 43| 860
650
| 47| 800
600
| 50| 725
530
| 55
–| –| –| –
| | Low| 655| –| 630| –| 610| –| 580| –| 550| –| 520| –| 480| –| 435| –
| | High*| 1350| 30| 1290| 31| 1225| 33| 1155| 35| 1100| 36| 1025| 39| 950|
42| 885| 45
SA054( )-23A
Side Return
| **** 54,000| Med-High
Med-Low**
| 1025
885
| 39
45
| 1015
855
| 39
47
| 1005
815
| 40
49
| 1000
780
| 40
51
| 990
740
| 40
54
| 920
695
| 43| 855
640
| 47| 775
565
| 52
–| –| –
| | Low| 700| –| 675| –| 655| –| 620| –| 590| –| 555| –| 515| –| 465| –
| | High*| 1685| 32| 1640| 33| 1605| 33| 1565| 34| 1515| 35| 1475| 36| 1415|
38| 1345| 40
SA072( )-24B
Bottom Return
| **** 72,000| Med-High
Med-Low**
| 1330
1175
| 40
45
| 1295
1155
| 41
46
| 1275
1125
| 42
47
| 1245
1100
| 43
48
| 1215
1075
| 44
50
| 1185
1045
| 45
51
| 1135
1010
| 47
53
| 1070
955
| 50
56
| | Low| 930| 57| 895| 60| 885| 60| 850| –| 825| –| 800| –| 770| –| 740| –
| | High*| 1770| 30| 1720| 31| 1685| 32| 1645| 32| 1590| 34| 1550| 34| 1485|
36| 1415| 38
SA072( )-24B
Side Return
| **** 72,000| Med-High
Med-Low**
| 1400
1235
| 38
43
| 1360
1215
| 39
44
| 1340
1180
| 40
45
| 1310
1155
| 41
46
| 1275
1130
| 42
47
| 1245
1100
| 43
48
| 1190
1060
| 45
50
| 1125
1005
| 47
53
| | Low| 975| 55| 940| 57| 930| 57| 890| 60| 865| –| 840| –| 810| –| 775| –
| | High*| 1610| 41| 1575| 42| 1530| 44| 1485| 45| 1440| 46| 1385| 48| 1340|
50| 1275| 52
SA090( )-24B
Bottom Return
| 90,000| Med- High**
Med-Low
| 1295
1155
| 51
58
| 1260
1130
| 53
59
| 1235
1100
| 54
61
| 1220
1070
| 55| 1175
1035
| 57| 1135
1015
| 59| 1095
965
| –
–
| 1015
920
| –
–
–| –| –
| | Low| 880| –| 860| –| 830| –| 800| –| 765| –| 740| –| 675| –| 660| –
| | High*| 1690| 39| 1655| 40| 1610| 41| 1560| 43| 1510| 44| 1455| 46| 1405|
47| 1340| 50
SA090( )-24B
Side Return
| ** 90,000| Med- High
Med-Low
| 1360
1215
| 49
55
| 1325
1190
| 50
56
| 1300
1155
| 51
58
| 1280
1125
| 52
59
| 1235
1090
| 54| 1190
1065
| 56| 1150
1015
| 58| 1065
965
| –
–
–| –| –
| | Low| 925| –| 900| –| 870| –| 840| –| 800| –| 775| –| 710| –| 695| –
| | High*| 1950| –| 1865| –| 1790| –| 1715| –| 1630| –| 1550| –| 1475| 36|
1390| 38
SA072( )-35C
Bottom Return
| **** 72,000| Med-High
Med-Low**
| 1860
1300
| –| 1780
1240
| –| 1710
1200
| –| 1635
1160
| –| 1575
1120
| –| 1500
1065
| 36
50
| 1415
995
| 38
54
| 1325
910
| 40
59
41| 43| 44| 46| 48
| | Low| 1165| 46| 1115| 48| 1060| 50| 1025| 52| 985| 54| 940| 57| 890| 60|
825| 65
| | High*| 2030| –| 1940| –| 1860| –| 1785| –| 1695| –| 1615| –| 1535| 35|
1445| 37
SA072( )-35C
Side Return
| **** 72,000| Med-High
Med-Low**
| 1935
1350
| –| 1850
1290
| –| 1780
1250
| –| 1700
1205
| –| 1340
1165
| 40
46
| 1560
1110
| –| 1470
1035
| 36
52
| 1380
945
| 39
56
40| 41| 43| 44| 48
| | Low| 1215| 44| 1160| 46| 1105| 48| 1065| 50| 1025| 52| 980| 54| 925| 58|
860| 62
BLOWER PERFORMANCE – FG7SA Continued
**Model Number| ****Heating Input (Btuh)| ****Motor Speed|
External Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise**|
SA072( )-35C
Side +
Bottom
or 2 Sides
| ****
72,000
| High* Med-High
Med-Low**
Low
| 2050
1955
1365
1225
| –
–
| 1960
1870
1300
1170
| –
–
| 1880
1800
1260
1115
| –
–
| 1800
1715
1220
1075
| –
–
| 1710
1655
1175
1035
| –
–
| 1630
1575
1120
985
| –
–
| 1550
1485
1045
935
| –| 1460
1390
955
865
| 37
38
56
62
|
36
51
57
|
39
44
| 41
46
| 42
48
| 44
50
| 45
52
| 48
54
|
| | High*| 1940| –| 1860| 36| 1790| 37| 1710| 39| 1625| 41| 1540| 43| 1450|
46| 1355| 49|
SA090( )-35C
Bottom Return
| ****
90,000
| Med-High**
Med-Low
| 1820
1290
| 37
52
| 1760
1245
| 38
54
| 1695
1200
| 39
56
| 1620
1155
| 41
58
| 1545
1110
| 43
60
| 1466
1060
| 45
63
| 1380
995
| 48| 1280
915
| 52|
–| –|
| | Low| 1145| 58| 1110| 60| 1070| 62| 1035| 64| 1000| –| 950| –| 905| –| 835|
–|
| | High*| 2020| –| 1935| –| 1860| 36| 1780| 37| 1690| 39| 1600| 42| 1510| 44|
1410| 47|
SA090( )-35C
Side Return
| ****
90,000
| Med-High**
Med-Low
| 1895
1345
| 35
50
| 1830
1295
| 36
51
| 1765
1250
| 38
53
| 1685
1200
| 40
56
| 1610
1155
| 41
58
| 1525
1100
| 44
61
| 1435
1035
| 46
64
| 1330
950
| 50|
–|
| | Low| 1190| 56| 1155| 58| 1115| 60| 1075| 62| 1040| 64| 980| –| 940| –|
870| –|
SA090( )-35C
Side +
Bottom
or 2 Sides
| ****
90,000
| High*
Med-High** Med-Low
Low
| 2040
1910
1355
1205
| –| 1955
1850
1310
1165
| –| 1880
1780
1260
1125
| 35
37
53
59
| 1795
1700
1215
1085
| 37
39
55
61
| 1705
1625
1165
1050
| 39
41
57
63
| 1620
1540
1115
1000
| 41
43
60
| 1525
1450
1050
950
| 44
46
63
| 1425
1345
960
875
| 47
50
|
35
49
55
| 36
51
57
|
–
–
|
–| –|
| | High*| 2205| 36| 2150| 37| 2095| 38| 2030| 39| 1970| 41| 1900| 42| 1830|
44| 1740| 46|
SA108( )-35C
Bottom Return
| ****
108,000
| Med-High**
Med-Low
| 2050
1700
| 39
47
| 1995
1680
| 40
48
| 1955
1645
| 41
49
| 1895
1610
| 42
50
| 1840
1565
| 43
51
| 1775
1525
| 45
52
| 1700
1460
| 47
55
| 1610
1375
| 50
58
|
| | Low| 1390| 58| 1370| 58| 1355| 59| 1320| 61| 1300| 62| 1270| 63| 1225| 65|
1175| –|
| | High*| 2295| 35| 2235| 36| 2180| 37| 2110| 38| 2050| 39| 1975| 41| 1900|
42| 1810| 44|
SA108( )-35C
Side Return
| ****
108,000
| Med-High**
Med-Low
| 2130
1770
| 38
45
| 2075
1750
| 39
46
| 2035
1710
| 39
47
| 1970
1675
| 41
48
| 1915
1630
| 42
49
| 1845
1585
| 43
50
| 1765
1520
| 45
53
| 1675
1430
| 48
56
|
| | Low| 1445| 55| 1425| 56| 1410| 57| 1375| 58| 1350| 59| 1320| 61| 1275| 63|
1225| 65|
| | High*| 2315| 35| 2260| 35| 2200| 36| 2130| 38| 2070| 39| 1995| 40| 1925|
42| 1825| 44|
SA108( )-35C
Side + Bottom
| ****
108,000
| Med-High** Med-Low| 2155
1785
| 37
45
| 2095
1765
| 38
45
| 2055
1725
| 39
46
| 1990
1690
| 40
47
| 1930
1645
| 41
49
| 1865
1600
| 43
50
| 1785
1535
| 45
52
| 1690
1445
| 47
55
|
or 2 Sides| | Low| 1460| 55| 1440| 56| 1425| 56| 1385| 58| 1365| 59| 1335| 60|
1285| 62| 1235| 65|
| | High*| 2255| 41| 2200| 42| 2125| 44| 2065| 45| 2010| 46| 1935| 48| 1855|
50| 1755| 53|
SA126( )-45D
Bottom only or 2 openings
| ****
126,000
| Med-High**
Med-Low
| 2075
1720
| 45
54
| 2025
1695
| 46
55
| 1970
1655
| 47
56
| 1940
1630
| 48
57
| 1875
1580
| 50
59
| 1810
1520
| 52
61
| 1750
1455
| 53
64
| 1680
1390
| 56
67
|
–| 1310| –| 1300| –| 1260| –| 1230| –|
| | Low| 1360| 69| 1375| 68| 1365| 68| 1315|
| | High*| 2230| 42| 2180| 43| 2105| 44| 2045| 46| 1990| 47| 1915| 49| 1835|
51| 1740| 54|
SA126( )-45D
Side Return
| ****
126,000
| Med-High**
Med-Low
| 2055
1705
| 45
55
| 2005
1680
| 47
56
| 1950
1640
| 48
57
| 1920
1615
| 49
58
| 1855
1565
| 50
60
| 1790
1505
| 52
62
| 1735
1440
| 54
65
| 1665
1375
| 56
68
|
| | Low| 1345| 69| 1360| 69| 1350| 69| 1300| –| 1230| –| 1290| –| 1250| –|
1220| –|
( ) Can be C or N
- Factory Set Cooling Speed ** Factory Set Heating Speed
NOTES
- Two openings are required for airflows above 1600 CFM if filter(s) is(are) adjacent to furnace.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are not recommended.
BLOWER PERFORMANCE – FG7SA Continued
Model Number
| ****
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
SK054( )-23A
| ****
54,000
| High* Med-High
Med-Low**
Low
| 1375
1155
790
650
| 29
35
51
| 1340
1130
775
640
| 30
35
52
| 1300
1110
765
630
| 31
36
52
| 1270
1085
750
610
| 31
37
53
| 1225
1055
730
590
| 33
38
55
| 1175
1015
700
565
| 34
39
| 1115
975
665
530
| 36
41
| 1035
910
610
480
| 39
44
|
–
–
| –
–
| –
–
|
–| –| –| –| –|
SK072( )-24B
| ****
72,000
| High* Med-High
Med-Low**
Low
| 1610
1295
1155
910
| 33
41
46
59
| 1590
1275
1135
885
| 34
42
47
60
| 1575
1260
1115
860
| 34
42
48
| 1560
1250
1095
835
| 34
43
49
| 1540
1220
1065
810
| 35
44
50
| 1495
1195
1040
785
| 36
45
51
| 1460
1170
1015
765
| 37
46
53
| 1415
1120
980
735
| 38
48
54
|
–| –| –| –| –| –|
SK090( )-24B
| ****
90,000
| High* Med-High
Med-Low**
Low
| 1675
1330
1180
940
| 40
50
56
| 1655
1315
1165
925
| 40
51
57
| 1640
1300
1150
900
| 41
51
58
| 1620
1280
1135
880
| 41
52
59
| 1590
1255
1115
850
| 42
53
60
| 1560
1230
1090
825
| 43
54
61
| 1520
1200
1060
795
| 44
56
63
| 1475
1150
1010
760
| 45
58
66
|
–| –| –| –| –| –| –| –|
SK108( )-35C
| ****
108,000
| High* Med-High
Med-Low**
Low
| 2395
2190
1785
1145
| 33
37
45
| 2335
2135
1770
1110
| 34
37
45
| 2285
2115
1740
1070
| 35
38
46
| 2230
2080
1725
1035
| 36
38
46
| 2200
2030
1685
1000
| 36
39
47
| 2140
1975
1645
950
| 37
41
49
| 2080
1915
1615
905
| 38
42
50
| 2000
1810
1565
835
| 40
44
51
|
–| –| –| –| –| –| –| –|
SK126( )-45D
| ****
126,000
| High* Med-High
Med-Low**
Low
| 2445
2195
1795
1480
| 38
43
52
63
| 2395
2170
1780
1475
| 39
43
52
63
| 2385
2140
1770
1450
| 39
44
53
64
| 2330
2120
1760
1440
| 40
44
53
65
| 2275
2090
1725
1440
| 41
45
54
65
| 2225
2030
1690
1415
| 42
46
55
| 2130
1975
1655
1405
| 44
47
56
| 2015
1855
1610
1375
| 46
50
58
|
–| –| –|
( ) Can be C or N
-
Factory Set Cooling Speed ** Factory Set Heating Speed
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are not recommended.
MODEL IDENTIFICATION CODE
SPECIFICATIONS
FG7SA MODEL NUMBERS| -045-23A| -054-23A| -072-24B| -090-24B| -072-35C|
-090-35C| -108-35C| -126-45D
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 54,000| 72,000| 90,000| 72,000| 90,000| 108,000|
126,000
Heating Capacity – Btuh| 36,000| 43,200| 57,600| 72,000| 57,600| 72,000|
86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 –
4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1.0 – 4 – PSC| 1.0 – 4 – PSC
Motor FLA| 4.80| 4.80| 8.20| 8.20| 7.50| 7.50| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70|
40-70
Shipping Weights| 100lbs| 100lbs| 110lbs| 115lbs| 115lbs| 120lbs| 125lbs|
145lbs
SKU| 905004F| 905005F| 904989F| 905006F| 905007F| 905008F| 905009F| 905010F
FG7SK MODEL NUMBERS| -054-23A| -072-24B| -090-24B| -108-35C| -126-45D
---|---|---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 43,200| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 3/4 –
4 – PSC| 1.0 – 4 -PSC
Motor FLA| 4.80| 8.20| 8.20| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 110lbs| 115lbs| 125lbs| 145lbs
SKU| 905011F| 905012F| 905013F| 905014F| 905015F
ACCESSORIES
FG7S (A, K) KITS
Description| SKU
“A” Cabinet fixed speed, high efficiency, FSHE| 904872
“B” Cabinet fixed speed, high efficiency, FSHE| 904873
“C” Cabinet fixed speed, high efficiency, FSHE| 904874
“D” Cabinet fixed speed, high efficiency, FSHE| 904875
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.) and High Altitude LP| 905028
Canada LP Conversion kit (0 to 4,500 ft.) and High Altitude LP| 905029
Side return filter kit| 541036
Furnace Twinning Kit| 1010035
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this
product which fails in normal use and service within the terms and conditions
of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (03/2019)
Broan® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>