Features

- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- 1 U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption <0. 75W
- 100% full load burn-in test
- High operating temperature up to 70°C
- Operating altitude up to 5000 meters (Note. 8)
- High efficiency, long life and high reliability
- 3 years warranty
Description
LRS-350 series is a 350W single-output enclosed type power supply with 30mm of
low profile design. Adopting the input of 11 SVAC or 230VAC (select by switch)
, the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V,
15V, 24V, 36V and 48V.
In addition to the high efficiency up to 89%, with the built-in long life fan
LRS-350 can work under -25~ + 70°C with full load. Delivering an extremely low
no load power consumption (less than 0. 75W), it allows the end system to
easily meet the worldwide energy requirement. LRS-350 has the complete
protection functions and 5G anti-vibration capability; it is complied with the
international safety regulations such as IEC/UL 62368-1. LRS-350 series serves
as a high price-to-performance power supply solution for various industrial
applications.
Model Encoding

Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment’s or apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL|  LRS-350-3.3|  LRS-350-4.2|  LRS-350-5|
LRS-350-12|  LRS-350-15|  LRS-350-24|  LRS -350-36|
LRS-350-48
---|---|---|---|---|---|---|---|---
OUTPUT|  DC VOLTAGE|  3.3V| 4.2V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT|  60A| 60A| 60A| 29A| 23.2A| 14.6A| 9.7A| 7.3A
CURRENT RANGE|  0 ~ 60A| 0 ~ 60A| 0 ~ 60A| 0 ~ 29A| 0 ~ 23.2A| 0 ~ 14.6A|
0 ~ 9.7A| 0 ~ 7.3A
RATED POWER|  198W| 252W| 300W| 348W| 348W| 350.4W| 349.2W| 350.4W
RIPPLE & NOISE (max.) **Note.2|  150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE|  2.97 ~ 3.6V| 3.6 ~ 4.4V| 4.5 ~ 5.5V| 10.2 ~ 13.8V|
13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3|  ±4.0%| ±4.0%| ±3.0%| ±1.5%| ±1.0%| ±1.0%|
±1.0%| ±1.0%
LINE REGULATION Note.4|  ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%| ±0.5%
LOAD REGULATION Note.5|  ±2.5%| ±2.5%| ±2.0%| ±1.0%| ±0.5%| ±0.5%|
±0.5%| ±0.5%
SETUP, RISE TIME|  1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)|  16ms/230VAC 12ms/115VAC at full load
INPUT|  VOLTAGE RANGE|  90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~
370VDC (switch on 230VAC)
FREQUENCY RANGE|  47 ~ 63Hz
EFFICIENCY (Typ.)|  79.5%| 81.5%| 83.5%| 85%| 86%| 88%| 88.5%| 89%
AC CURRENT (Typ.)|  6.8A/115VAC 3.4A/230VAC
INRUSH CURRENT (Typ.)|  60A/115VAC 60A/230VAC
LEAKAGE CURRENT|  <2mA / 240VAC
PROTECTION|  OVER LOAD|  110 ~ 140% rated output power
3.3~36V Hiccup mode, recovers automatically after fault condition is removed.
48V Shut down and latch off o/p voltage, re-power on to recover.
OVER VOLTAGE|  3.8 ~ 4.45V| 4.6 ~ 5.4V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18 ~
21V| 28.8 ~ 33.6V| 41.4 ~ 46.8V| 55.2 ~ 64.8V
3.3~36V Hiccup mode, recovers automatically after fault condition is removed.
48V Shut down and latch off o/p voltage, re-power on to recover.
OVER TEMPERATURE|  3.3~36V Hiccup mode, recovers automatically after
fault condition is removed. 48V Shut down and latch off o/p voltage, re-power
on to recover.
FUNCTION|  FAN ON/OFF CONTROL (Typ.)|  RTH3≧50℃ FAN ON, ≦40℃ FAN
OFF
ENVIRONMENT|  WORKING TEMP.|  -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY|  20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY|  -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT|  ±0.03%/℃ (0 ~ 50℃)
VIBRATION|  10 ~ 500Hz, 5G 10 min./1 cycle, 60min. each along X, Y, Z
axes
OVERVOLTAGE CATEGORY|  Ⅲ: According to EN61558, EN50178, EN60664-1,
EN62477-1; altitude up to 2000 meters
SAFETY|  SAFETY STANDARDS|  IEC/UL 62368-1, BSMI CNS15598-1, EAC TP
TC 004, KC K60950-1 (for LRS-350-12/24 only), BIS  IS13252(Part1): 2010/IEC
60950-1: 2005, BS EN/EN61558-1, BS  EN61558-2-16 Designed by AS/NZS
61558.1/2.16, AS/NZS 62368.1,BS EN/EN62368-1,
WITHSTAND VOLTAGE|  I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE|  I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/
70% RH
EMC EMISSION|  Compliance to BSMI CNS15936, EAC TP TC 020,KC
KN32,KN35(for LRS-350-12/24 only)
EMC IMMUNITY|  Compliance to BS EN/EN55035, EAC TP TC 020,KC
KN32,KN35(for LRS-350-12/24 only)
OTHERS|  MTBF|  2099.9K hrs min. Telcordia SR-332 (Bell core) ;
328.6Khrs min. MIL-HDBK-217F (25℃)
DIMENSION|  21511530mm (LWH)
PACKING|  0.76Kg; 15pcs/12.4Kg/0.67CUFT
NOTE**|
- 
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 
- 
Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 
- 
Tolerance: includes set up tolerance, line regulation and load regulation. 
- 
Line regulation is measured from low line to high line at rated road. 
- 
Load regulation is measured from 0% to 100% rated load. 
- 
Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 
- 
The 150% peak load capability is built in for up to 1 second for 12~48V. LRS-350 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level (115VAC/230VAC). 
- 
The ambient temperature derating of 5°C/1 000m is needed for operating altitude greater than 2000m (6500ft). 
- 
This power supply does not meet the harmonic current requirements outlined by BS EN/ENS 1000-3-2. Please do not use this power supply under the following conditions: 
 a) the end-devices is used within the European Union, and
 b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
 c) the power supply is:- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system
 Exception:
 Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2
 a) professional equipment with a total rated input power greater than 1000W;
 b) symmetrically controlled heating elements with a rated power less than or equal to 200W
 
- 
RCM is on voluntary basis and meets relevant JEC or AS/NZ.S standards complying with AS/NZS 4417.1. 
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.oom/serviceDisclaimer.aspx
Block Diagram

Derating Curve

Static Characteristics

Mechanical Specification

Terminal Pin No. Assignment:
| Pin No. | Assignment | Pin No. | Assignment | 
|---|---|---|---|
| 1 | AC/L | 4~6 | DC OUTPUT -V | 
| 2 | AC/N | 7~9 | DC OUTPUT +V | 
| 3 | FG | 