VEVOR XKJ-805S-1 Shallow Well Pump Instruction Manual
- June 15, 2024
- VEVOR
Table of Contents
VEVOR XKJ-805S-1 Shallow Well Pump Instruction Manual
XKJ-805S-1
**XKJ-1105S
**
This is the original instructions, please read all manual instructions carefully before operating. VEVOR reserves clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there is any technology or software updates on our product.
This appliance can be used by people aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Attention!
If the appliance or the supply cord is damaged, it must be repaired by the
manufacturer, its service agent or a qualified person. )
Meaning of crossed-out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection faculties. Contact your local government for information regarding the collection systems available.
Read the instructions carefully and follow the rules for safe operation. The operator shall take full responsibility for personal injury, pump damage and other property losses caused by violation of safety cautions.
APPLICALTION
It is applicable to household water supply, equipment support, well water lifting, pipeline pressurization, garden watering, vegetable greenhouse watering, fish farming and poultry raising, etc.
Transfer clean water and other non-corrosive liquids with low viscosity; do not transport inflammable, explosive, gasified liquids and liquids containing solid particles or fibers. The liquid PH value shall be between 6.5 and 85.
Remark:
The pump can work automatically, equipped with a pressure tank, a pressure switch and other necessary parts. Function features of the automatic pump are as follows: when the power is on, turn on the water tap and the pump will start working automatically; when the water tap is turned off, the pump will stop working automatically. If a water tower is used along with the automatic pump, connect to the upper limit switch and the pump will start or stop working automatically with the water level in the water tower.
TECHNICAL DATA
Model | XKJ-805S-1 | XKJ-1105S |
---|---|---|
Nominal voltage | 115V – , 60Hz | 110-120V — 60Hz |
Amp | 7A | 10A |
Max.head | 40m | 50m |
Max.flow | 3.7m3/h | 4.5m3/h |
Max.Suction depth | 8m | 8m |
Protection class | IPX4 | IPX4 |
Insulation class | F | F |
Max. ambient temperature | +40°C | +40°C |
Max. Iiquid temperature | +35°C | +35°C |
Safety Precautions
-
To ensure normal and safe operation of the electric pump, read the manual carefully before use.
-
To avoid electric shock, make sure the pump is safely grounded and equipped with an earth leakage circuit breaker. Do not get the plug wet and do not use any socket in an area with high humidity.
-
Do not touch the electric pump while working; do not wash, swim near the working area or let livestock into the water to avoid accidents.
-
Avoid splashing pressured water to the electric pump. Do not immerse the pump in water.
-
Keep the pump in a well-ventilated place.
-
If the environment temperature is below 4°C or after a long period of non-use, the liquid inside shall be discharged for freeze and frost protection.
-
The pumped liquid may be hot and under high pressure, so before moving and disassembling the pump, valves in both sides of the pump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded.
-
Never use the pump to transport inflammable, gasifying or explosive liquid that exceeds the specified liquids in this manual.
-
The power supply should be in accordance with the voltage stated in the nameplate. If the pump is not be used for a long time, empty it completely,
PAPILINE INSTALLATION
This product shall be installed and maintained by a qualified person who s proficient with this instruction. The installation and operation must be in accordance with local regulations and the recognized operation criteria. Install the pipeline properly according to the requirement of this instruction, and protect it from freezing.
- Make the inlet pipeline as short as possible and keep bends as few as possible during installation. Keep the pump in a dry and well- ventilated place. In condition of outdoor installation, make sure the pump is properly protected by weather-proof covering.
- Installation of valves on inlet and out let pipelines is necessary. The valve installed on inlet pipeline shall be one-way valve.
Correct Installation Diagram [A]
A:
- Drain plug
- Electric ump
- Water tap
- Outlet pipe
- Filling plug
- Tie-in
- Inlet pipe
- Foot valve
Incorrect Installation Diagram B
Notes for inlet pipeline installation:
-
Do not use soft rubber tube for inlet pipeline during pump installation.
-
The bottom valve shall be vertically installed with a distance of 30 cm from the water bottom to avoid suction of sediment (B1).
-
All connections of the inlet pipeline must be sealed. To ensure water suction, it” s necessary to reduce the quantity of bents of the pipeline.
-
The diameter of inlet pipeline must not be less than that of the pump inlet to avoid big hydraulic loss and small water flow.
-
Pay attention to the water level during operation.
The bottom valve shall not be above the water surface (B2). -
In case the inlet pipeline is more than 10 m in length or over 4 m in hoisting height, the diameter of the inlet pipeline must be bigger than
Note for outlet pipeline installation:
The diameter of the outlet pipeline shall be not less than that of the pump outlet to reduce the pressure drop, high flow rate and
START-UP AND MAINTENANCE
Do not switch on the pump if the pump chamber is not fully illed with water. Do not touch the electric pump unless the power of pump is cut off for over 5 minutes. Do not remove the pump bonnet unless the water in pump chamber is completely drained.
Stir the fan with a screwdriver to check if the pump rotates flexibly before
startup. Remove the filling plug and prime the pump chamber fully with clean
water, then screw the flling plug. Keep the valve wide opened during startup.
When the pump runs normally, adjust the valve to the required flow (The range
of flow and head is shown on the nameplate).
Note:
- If no water can be pumped in 5 minutes after the pump s filled with water and started up, turn off and refill the pump, or check the leakage of inlet pipelines, then restart the pump.
- For frost and freeze protection, remove the discharge plug on the air tank and drain the water in the pump chamber completely. Before restarting the pump, it’s necessary to remove the filling plug, fill the pump fully with water, and then screw the filling plug.
- If not used for a long time, discharge the water in the pump chamber and store the pump in a dry, well-ventilated place.
- If the ambient temperature is high, make sure the pump works in a well- ventilated place to avoid electrical faults caused by dew on electrical parts
- In the case of overheat or abnormal operation of the pump motor, cut off the power supply immediately, and check the faults according to the following form,
TROBLESHOOTING
Check the pump after power cut-off
Symptom | Cause | Corrective Action |
---|---|---|
The motor can not be started | **Single-phase power supply(three-phase |
electric motor):
a. poor connection of the power switch;
b. fuse is burned out;
c. loose power lead;
d. phase failure of the cable.| a. repair switch contactor replace
the switch;
b. replace the safety fuse;
c. check and tighten the power connector;
d. repair or replace cables.
The capacitor is burned out.| Replace with a same type capacitor(send to the
maintenance point for repair).
The rotating shaft and bearing are jammed.| Replace the bearing(send to the
maintenance point for repair).
The impeller is jammed.| Turn the rotating shaft of the fan blade terminal
with a screwdriver to let it rotate flexibly or demount thump bodytoclear
sundries.
The stator winding is damaged.| Replace winding coils(send to the maintenance
point for repair).
The motor is in operation, but no water is discharged| Incorrect direction of
pump rotation.| In Vert two-phase wirings of the motor
(three-phase motor).
The pump is not fully filled with water.| Re-fill the pump with water.
The impeller is damaged.Replace the impeller| (send to the maintenance point
for repair).
Leakage of the suction pipe. pipelines.| Check the tightness of various joints
of the inlet
Water level is too low.| Adjust installation height of the pump.
Freeze caused by accumulated water in the pipeline or the chamber.| Start up
the pump after the ice is melted.
Water that is too hot can result in the failure of plastic pant| Replace the
damaged parts(send to the maintenance point for repair).
Symptom| Cause| Corrective Action**
---|---|---
Insufficient pressure.| Incorrect pump type.| Select a suitable model.
The inlet pipeline is too long or with too many bedsore/and the pipe diameter
is not selected as required.| Apply the pipe with the stipulated diameter, and
make the inlet pipe short.
The inlet pipeline, filter screen or pump chamber is blocked by foreign
materials.| Clean pipeline, foot valve or pump chamber, clear foreign
materials.
Motor works intermittently or the stator winding is burned out| The impeller
is jammed or in overload operation for a long time.| Clear for eignmaterials
inthe pumpchamber; operate the pump under the rated flow.
Incorrect grounding, broken cable or the electric pump is struck by
lightning.| Properly grounded, replace the broken cable, and replace winding
coils.
E-mail: CustomerService@vevor.com
Manufacturer: Leo Group Pump(Zhejiang) Co., Ltd.
Add: NO.1, 3rd Street, East Industry Center, Wenling 317500 Zhejiang P.R.
China.
Made in China
Read User Manual Online (PDF format)