Deltatherm DTR0170 Floor Heating Cable for Membrane Instructions
- June 15, 2024
- Deltatherm
Table of Contents
Deltatherm DTR0170 Floor Heating Cable for Membrane Instructions
Features
Voltage
- 120V, 240/208V, 1-phase.
Cold lead length
- 10’ (3 m).
Construction
- Heating cable made of a twin conductor for a simpler and faster installation, compatible with uncoupling membrane systems.
Watt density
- 9W/sq. ft. (97W/sq. m), 4” (102 mm) spacing.
- 10W/sq. ft. (108W/sq. m), 3 5/8” (92 mm) spacing.
Control
- Two types of control method possible (see instruction manual for details):
- Surface heating control with electronic thermostat in floor mode (F) and temperature sensor.
- Ambient heating control with electronic thermostat in ambient mode with floor limit (A or AF) and temperature sensor.
Note: A ground fault circuit interrupter (GFCI) must be used with this heating device unless exempted by the applicable national and/or local electrical code for the area of installation.
Included materials
- 15′ (4.6 m) floor sensor.
- Measurements table label (to be placed in electrical panel).
Installation
- Never cut or shorten the heating cable.
- For indoor applications only.
- On concrete slab or plywood subfloor.
- On uncoupling membrane sold in option.
- For heating cable installation on uncoupling membrane systems, consult the membrane manufacturer’s instructions to ensure that it is compatible with the use of heating cables.
Warranty
- 25-year warranty on the heating cable.
Application
- Kitchen, bathroom, entrance way, family room, living room.
Models
|
Covered surface depending on spacing 1
---|---
3 1/2’’ (88 mm)2
|
3 3/4’’ (95 mm)
|
Length
|
Weight
Watts| Product # 240/208V| Product # 120V| Cable diameter (mm)| 10W/sq. ft.|
108W/sq. m| 9.6W/sq. ft.| 9.6W/sq. ft.| ft.| m| lb| kg
85| –| DTR 0082| 4.3| 9.5| 0.9| 10.0| 0.9| 32| 9.75| 2.6| 0.9
120| –| DTR 0122| 4.3| 12.0| 1.1| 12.5| 1.2| 40| 12.19| 2.6| 0.9
150| –| DTR 0152| 4.3| 16.0| 1.5| 16.5| 1.5| 53| 16.15| 3.1| 1.4
170| DTR 0170| DTR 0172| 4.3| 18.5| 1.7| 19.0| 1.8| 61| 18.59| 3.1|
1.4
240| DTR 0240| DTR 0242| 4.3| 24.0| 2.2| 25.0| 2.3| 80| 24.38| 3.8|
1.6
300| DTR 0300| DTR 0302| 4.3| 30.5| 2.8| 31.5| 2.9| 101| 30.78| 4|
1.8
360| DTR 0360| DTR 0362| 4.3| 36.5| 3.4| 37.5| 3.5| 120| 36.58|
4.2| 1.9
420| DTR 0420| DTR 0422| 4.3| 42.5| 4.0| 44.0| 4.1| 141| 42.98|
4.9| 2.2
475| DTR 0475| DTR 0472| 4.3| 48.5| 4.5| 50.0| 4.6| 160| 48.77| 6|
2.7
600| DTR 0600| DTR 0602| 4.3| 60.5| 5.6| 62.5| 5.8| 200| 60.96|
6.9| 3.1
720| DTR 0720| DTR 0722| 4.3| 72.5| 6.7| 75.0| 7.0| 240| 73.15|
7.9| 3.6
840| DTR 0840| DTR 0842| 4.3| 84.5| 7.9| 87.5| 8.1| 280| 85.34|
8.7| 4
960| DTR 0960| DTR 0962| 4.3| 96.5| 9.0| 100.0| 9.3| 320| 97.54|
9.3| 4.2
1080| DTR 1080| –| 4.3| 109.0| 10.1| 112.5| 10.5| 360| 109.73| 10|
4.6
1140| –| DTR 1142| 4.3| 115| 10.66| 119| 11.03| 380| 115.82| 11.6|
5.2
1200| DTR 1200| –| 4.3| 121.0| 11.2| 125.0| 11.6| 400| 121.92| 11|
5
1320| –| DTR 1322| 4.3| 133| 12.35| 137.5| 12.77| 440| 134.11|
13.7| 6.2
1440| DTR 1440| –| 4.3| 145.0| 13.5| 150.0| 13.9| 480| 146.30| 13|
5.9
1450| –| DTR 1452| 4.3| 145| 13.5| 150| 13.9| 480| 146.30| 16| 7.2
1500| –| DTR 1502| 4.3| 151| 14| 156.5| 14.5| 500| 152.40| 17.4|
7.9
1600| DTR 1600| –| 4.3| 169.0| 15.7| 175.0| 16.3| 560| 170.69| 15|
6.8
1680| –| DTR 1682| 4.3| 169.5| 15.7| 175| 16.3| 560| 170.69| 20.3|
9.1
1920| DTR 1920| –| 4.3| 193.5| 18.0| 200.0| 18.6| 640| 195.07| 18|
8.2
2280| DTR 2280| –| 4.3| 229.5| 21.3| 237.5| 22.1| 760| 231.65| 22|
10
2640| DTR 2640| –| 4.3| 266.0| 24.7| 275.0| 25.5| 880| 268.22| 26|
11.8
2900| DTR 2900| –| 4.3| 292.5| 27.2| 302.5| 28.1| 968| 295.04| 30|
13.6
3000| DTR 3000| –| 4.3| 302.0| 28.1| 312.5| 29.0| 1000| 304.80| 31|
14
3360| DTR 3360| –| 4.3| 338.5| 31.4| 350| 32.5| 1120| 341.38| 36.9|
16.8
- Does not represent the surface of the room but rather the surface covered by the floor heating system, excluding fixtures and other spaces to consider.
- Spacing with the NADCM membrane when the cable is installed with 3 spacing castellations. 208V = 75% of wattage at 240V.
15′ (4.6 m) floor sensor and 10′ (3 m) cold lead included.
Options
Product # Kit | Description |
---|---|
NADCM-M-80 | Fleeceback uncoupling membrane in sheet, 2’ 6-5/16’’ X 3’ 3’’, |
8.16 sq. ft., sold in box of 10 sheets
NADCM-M-150| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq.
ft.
NADCM-S-80| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq.
ft.
NADCM-S-150| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq.
ft.
OTM-CC| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
OTM-SA| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
KIT-SP1| Repair kit
KIT-CBL-SN| 15 ft. (4.6 m) floor sensor