Deltatherm DTR0170 Floor Heating Cable for Membrane Instructions

June 15, 2024
Deltatherm

Deltatherm DTR0170 Floor Heating Cable for Membrane Instructions

Deltatherm DTR0170 Floor Heating Cable for Membrane
Instructions

Features

Voltage

  • 120V, 240/208V, 1-phase.

Cold lead length

  • 10’ (3 m).

Construction

  • Heating cable made of a twin conductor for a simpler and faster installation, compatible with uncoupling membrane systems.

Watt density

  • 9W/sq. ft. (97W/sq. m), 4” (102 mm) spacing.
  • 10W/sq. ft. (108W/sq. m), 3 5/8” (92 mm) spacing.

Control

  • Two types of control method possible (see instruction manual for details):
    • Surface heating control with electronic thermostat in floor mode (F) and temperature sensor.
    • Ambient heating control with electronic thermostat in ambient mode with floor limit (A or AF) and temperature sensor.
      Note: A ground fault circuit interrupter (GFCI) must be used with this heating device unless exempted by the applicable national and/or local electrical code for the area of installation.

Included materials

  • 15′ (4.6 m) floor sensor.
  • Measurements table label (to be placed in electrical panel).

Installation

  • Never cut or shorten the heating cable.
  • For indoor applications only.
  • On concrete slab or plywood subfloor.
  • On uncoupling membrane sold in option.
  • For heating cable installation on uncoupling membrane systems, consult the membrane manufacturer’s instructions to ensure that it is compatible with the use of heating cables.

Warranty

  • 25-year warranty on the heating cable.

Application

  • Kitchen, bathroom, entrance way, family room, living room.

Features

Models

|

Covered surface depending on spacing 1

---|---

 3 1/2’’ (88 mm)2

|

 3 3/4’’ (95 mm)

|

 Length

|

 Weight

Watts| Product # 240/208V| Product # 120V| Cable diameter (mm)| 10W/sq. ft.| 108W/sq. m| 9.6W/sq. ft.| 9.6W/sq. ft.| ft.| m| lb| kg
85| | DTR 0082| 4.3| 9.5| 0.9| 10.0| 0.9| 32| 9.75| 2.6| 0.9
120| | DTR 0122| 4.3| 12.0| 1.1| 12.5| 1.2| 40| 12.19| 2.6| 0.9
150| | DTR 0152| 4.3| 16.0| 1.5| 16.5| 1.5| 53| 16.15| 3.1| 1.4
170| DTR 0170| DTR 0172| 4.3| 18.5| 1.7| 19.0| 1.8| 61| 18.59| 3.1| 1.4
240| DTR 0240| DTR 0242| 4.3| 24.0| 2.2| 25.0| 2.3| 80| 24.38| 3.8| 1.6
300| DTR 0300| DTR 0302| 4.3| 30.5| 2.8| 31.5| 2.9| 101| 30.78| 4| 1.8
360| DTR 0360| DTR 0362| 4.3| 36.5| 3.4| 37.5| 3.5| 120| 36.58| 4.2| 1.9
420| DTR 0420| DTR 0422| 4.3| 42.5| 4.0| 44.0| 4.1| 141| 42.98| 4.9| 2.2
475| DTR 0475| DTR 0472| 4.3| 48.5| 4.5| 50.0| 4.6| 160| 48.77| 6| 2.7
600| DTR 0600| DTR 0602| 4.3| 60.5| 5.6| 62.5| 5.8| 200| 60.96| 6.9| 3.1
720| DTR 0720| DTR 0722| 4.3| 72.5| 6.7| 75.0| 7.0| 240| 73.15| 7.9| 3.6
840| DTR 0840| DTR 0842| 4.3| 84.5| 7.9| 87.5| 8.1| 280| 85.34| 8.7| 4
960| DTR 0960| DTR 0962| 4.3| 96.5| 9.0| 100.0| 9.3| 320| 97.54| 9.3| 4.2
1080| DTR 1080| | 4.3| 109.0| 10.1| 112.5| 10.5| 360| 109.73| 10| 4.6
1140| | DTR 1142| 4.3| 115| 10.66| 119| 11.03| 380| 115.82| 11.6| 5.2
1200| DTR 1200| | 4.3| 121.0| 11.2| 125.0| 11.6| 400| 121.92| 11| 5
1320| | DTR 1322| 4.3| 133| 12.35| 137.5| 12.77| 440| 134.11| 13.7| 6.2
1440| DTR 1440| | 4.3| 145.0| 13.5| 150.0| 13.9| 480| 146.30| 13| 5.9
1450| | DTR 1452| 4.3| 145| 13.5| 150| 13.9| 480| 146.30| 16| 7.2
1500| | DTR 1502| 4.3| 151| 14| 156.5| 14.5| 500| 152.40| 17.4| 7.9
1600| DTR 1600| | 4.3| 169.0| 15.7| 175.0| 16.3| 560| 170.69| 15| 6.8
1680| | DTR 1682| 4.3| 169.5| 15.7| 175| 16.3| 560| 170.69| 20.3| 9.1
1920| DTR 1920| | 4.3| 193.5| 18.0| 200.0| 18.6| 640| 195.07| 18| 8.2
2280| DTR 2280| | 4.3| 229.5| 21.3| 237.5| 22.1| 760| 231.65| 22| 10
2640| DTR 2640| | 4.3| 266.0| 24.7| 275.0| 25.5| 880| 268.22| 26| 11.8
2900| DTR 2900| | 4.3| 292.5| 27.2| 302.5| 28.1| 968| 295.04| 30| 13.6
3000| DTR 3000| | 4.3| 302.0| 28.1| 312.5| 29.0| 1000| 304.80| 31| 14
3360| DTR 3360| | 4.3| 338.5| 31.4| 350| 32.5| 1120| 341.38| 36.9| 16.8

  1. Does not represent the surface of the room but rather the surface covered by the floor heating system, excluding fixtures and other spaces to consider.
  2. Spacing with the NADCM membrane when the cable is installed with 3 spacing castellations. 208V = 75% of wattage at 240V.
    15′ (4.6 m) floor sensor and 10′ (3 m) cold lead included.

Options

Product # Kit Description
NADCM-M-80 Fleeceback uncoupling membrane in sheet, 2’ 6-5/16’’ X 3’ 3’’,

8.16 sq. ft., sold in box of 10 sheets
NADCM-M-150| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
NADCM-S-80| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
NADCM-S-150| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
OTM-CC| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
OTM-SA| Fleeceback uncoupling membrane in roll, 46′ 9” x 3′ 3”, 150 sq. ft.
KIT-SP1| Repair kit
KIT-CBL-SN| 15 ft. (4.6 m) floor sensor