SCHNEIDER ELECTRIC LAD4DDL TeSys Deca U-Line Transient Suppressor User Manual

May 15, 2024
Schneider Electric

SCHNEIDER-ELECTRIC-LOGO

SCHNEIDER ELECTRIC LAD4DDL TeSys Deca U-Line Transient Suppressor

Product Information

Specifications

  • Product Name: TeSys Deca U-Line Transient Suppressor
  • Model Number: LAD4DDL
  • Functional Unit: Suppressor module for contactors and control relays CAD
  • Materials: Brass (20%), Electronic components (6.5%), Paper (0.1%), PA Polyamide (73.4%)
  • Reference Product Mass: 12g

Product Usage Instructions

Description
The TeSys Deca U-Line Transient Suppressor is designed to provide flywheel diode protection against transient overvoltage for contactors and control relays CAD. It features clip-on side mounting and maintains the overall size of the contactor.

Installation
The TeSys Deca U-Line Transient Suppressor, model LAD4DDL, does not require any installation operations. It is designed to be easily integrated with compatible contactors and control relays.

Usage Scenario
The product is suitable for applications where a 30% load rate of the rated current is required, with a utilization time of 30%.

Environmental Information
The product is made of environmentally friendly materials with a recyclability potential of 20%. Detailed information on the environmental impacts, service life, and energy model used can be found in the product environmental profile.

FAQ

Q: Where can I find information on ROHS and REACH substances?
A: Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website at https://www.se.com/ww/en/work/support/green-premium/

Q: What is the recyclability rate of the product?
A: The recyclability rate of the product is 20%, calculated based on the REEECY’LAB tool developed by Ecosystem.

Q: What is the service life time of the product?
A: The reference service life time of the product is 20 years.

General information

Reference product LAD4DDL
Description of the product TeSys Deca suppressor module, for contactors

and control relays CAD.
Description of the range| The range product report includes :Suppressors modules, TeSys Deca,the representative product number: LAD4DDL
The environmental impacts of this reference product are representative of the impacts of the other products of the range which are developed with a similar technology.
Functional unit| It provides a flywheel diode protection ensuring no transient overvoltage. Clip-on side mounting, overall size of the contactor is unchanged.

Constituent materials

Reference product mass 12 g including the product, its packaging and additional elements and accessories

SCHNEIDER-ELECTRIC-LAD4DDL-TeSys-Deca-U-Line-Transient-
Suppressor-1

Substance assessment

Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website https://www.se.com/ww/en/work/support/green-premium/

Additional environmental information

End Of Life| Recyclability potential:| 20%| Recyclability rate has been calculated based on REEECY’LAB tool developed by Ecosystem, for components/materials not covered by the tool, data from the “ECO’DEEE recyclability and recoverability calculation method” was taken. If no data was found a conservative assumption was used (0% recyclability).
---|---|---|---

Environmental impacts

Reference service life time 20 years
Product category Other equipments – Passive product – non-continuous

operation
Installation elements| Ref LAD4DDL does not require any installation operations.
Use scenario| load rate / rated current (In): 30 % of In percentage of utilization time: 30%

Technological representativeness

| The Modules of Technologies such as material production, manufacturing process and transport technology used in this PEP analysis (LCA-EIME in this case) are Similar and representative of the actual type of technologies used to make the product in production
Geographical representativeness| France
 | [A1 – A3]| [A5]| [B6]| [C1 – C4]
Energy model used| Electricity Mix; Production mix; Low voltage; FR| Electricity Mix; Production mix; Low voltage; FR| Electricity Mix; Production mix; Low voltage; FR| Electricity Mix; Production mix; Low voltage; FR

Mandatory Indicators TeSys Deca U-Line Transient Suppressor – LAD4DDL

Impact indicators| Unit| Total| Manufacturing

[A1 – A3]

| Distribution

[A4]

| Installation

[A5]

| Use

[B1 – B7]

| End of Life

[C1 – C4]

| Benefits

[D]

Contribution to climate change| kg CO2 eq| 1.49E-01| 1.10E-01| 1.45E-03| 0| 0| 3.68E-02| -1.16E-02
Contribution to climate change-fossil| kg CO2 eq| 1.48E-01| 1.10E-01| 1.45E-03| 0| 0| 3.68E-02| -1.15E-02
---|---|---|---|---|---|---|---|---
Contribution to climate change-biogenic| kg CO2 eq| 7.81E-04| 7.81E-04| 0| 0| 0| 0| -2.70E-05
Contribution to climate change-land use and land use change| kg CO2 eq| 0.00E+00| 0| 0| 0| 0| 0*| 0.00E+00

Contribution to ozone depletion

| kg CFC-11

eq

|

9.69E-09

|

9.57E-09

|

2.22E-12

|

0*

|

0*

|

1.11E-10

|

-3.58E-09

Contribution to acidification

|

mol H+ eq

|

1.02E-03

|

9.82E-04

|

9.19E-06

|

0*

|

0*

|

3.29E-05

|

-6.28E-05

Contribution to eutrophication, freshwater| kg (PO4)³¯ eq| 1.76E-06| 1.76E-06| 5.44E-10| 0| 0| 1.50E-09| -3.55E-08
Contribution to eutrophication marine| kg N eq| 1.73E-04| 1.62E-04| 4.31E-06| 0| 0| 6.77E-06| -6.35E-06
Contribution to eutrophication, terrestrial| mol N eq| 1.81E-03| 1.68E-03| 4.73E-05| 0| 0| 8.21E-05| -7.10E-05
kg|  |  |  |  |  |  |
Contribution to photochemical ozone formation – human health COVNM| 5.47E-04| 5.11E-04| 1.19E-05| 0| 0| 2.45E-05| -2.73E-05
eq|  |  |  |  |  |  |
Contribution to resource use, minerals and metals| kg Sb eq| 3.59E-06| 3.59E-06| 0| 0| 0| 0| -1.66E-06

Contribution to resource use, fossils

|

MJ

|

2.41E+00

|

1.87E+00

|

2.02E-02

|

0*

|

0*

|

5.23E-01

|

-1.58E-01

Contribution to water use| m3 eq| 4.16E-02| 3.64E-02| 5.51E-06| 0| 0| 5.21E-03| -5.06E-03

represents less than 0.01% of the total life cycle of the reference flow Life cycle assessment performed with EIME version v5.9.4, database version 2022-01 in compliance with ISO14044.

Detailed results, including all the optional indicators mentioned in PCRed4, and the split of the Use Phase (B1 to B7), are available in the LCA report and on demand in a digital format – Country Customer Care Center – http://www .schneider-electric.com/contact

According to this environmental analysis, proportionality rules may be used to evaluate the impacts of other products of this range, ratios to apply can be provided upon request

Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the environmental assessment of an installation.

Registration number :| ENVPEP111253EN_V2| Drafting rules| PEP-PCR- ed4-2021 09 06
---|---|---|---
Verifier accreditation N°|  | Supplemented by| PSR-0005-ed2-2016 03 29
Date of issue| 2024/02/05| Information and reference documents| www .pep-ecopassport.org
 |  | Validity period| 5 years
Independent verification of the declaration and data, in compliance with ISO 14021 : 2016

Internal                      X                   External

The PCR review was conducted by a panel of experts chaired by Julie ORGELET (Ddemain) PEP are compliant with XP C08-100-1 :2016 or EN 50693:2019

The elements of the present PEP cannot be compared with elements from another program.

Document in compliance with ISO 14021 : 2016 « Environmental labels and declarations. Type II environmental declarations »

Schneider Electric Industries SAS Country Customer Care Center
http://www.schneider-electric.com/contact 35, rue Joseph Monier
CS 30323
F- 92500 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776 €

www.se.com
ENVPEP111253EN_V2

Published by Schneider Electric
©2023 – Schneider Electric – All rights reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals