Champion Power Equipment 100900 2000W Dual Fuel Inverter Generator User Guide
- June 15, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
Champion Power Equipment 100900 2000W Dual Fuel Inverter Generator
Product Information
Specifications
- Model: 100900 – 2000W Dual Fuel Inverter Generator
- Power Output: 2000W
- Fuel Type: Dual Fuel (Gasoline and Propane)
Product Usage Instructions
Engine will not start
Possible causes:
- No fuel
- Faulty spark plug
- Low oil level
- Spark plug wire loose
- Fuel valve is closed
- Old fuel or water in fuel
- Flooded with fuel
- Choke in the wrong position
Engine starts but runs roughly
Possible causes:
- Dirty air filter
- Dirty fuel valve
- Clogged spark arrestor
- Out of fuel
Engine shuts down during operation
Possible causes:
- Low oil level
- Clogged spark arrestor
Generator cannot supply enough power or overheating
Possible causes:
- Generator is overloaded
- Dirty air filter
- Choke in wrong position
Engine is running but no AC output
Possible causes:
- Poor cord connection
- Circuit breaker is open
- Loose wiring
AC Overload: Button illuminated red
Possible causes:
- Engine hunts or falters
- Other issues
- Engine governor defective
- Dirty fuel valve
- Carburetor is dirty and running lean
- Choke in wrong position
Dual Fuel Models Only: Engine will not stop
Possible causes:
- Propane valve is still open
- Overload
Repeated circuit breaker tripping
Possible causes:
- Faulty power cords or device
- Circuit breaker still too hot
TROUBLESHOOTING
Problem
Cause | Solution |
---|---|
Engine will not start. |
- No fuel. – Add fuel.
- Faulty spark plug. – Clean and adjust spark plug or replace.
- Low oil level. – Fill crankcase to the proper level.
- Spark plug wire loose. – Attach wire to spark plug.
- Fuel valve is closed. – Open fuel valve.
- Old fuel or water in fuel. – Drain fuel and replace with fresh fuel.
- Flooded with fuel. – Let unit stand for 10 mins.
- Choke in the wrong position. – Move choke until it stops under RUN position or push in completely.
Engine starts but runs roughly.|
- Dirty air filter. – Clean or replace air filter.
- Dirty fuel valve. – Clean the fuel valve.
- Clogged spark arrestor. – Clean spark arrestor.
- Out of fuel. – Fill fuel tank.
Engine shuts down during operation.|
- Low oil level. – Fill crankcase to the proper level. Place generator on a flat, level surface.
- Clogged spark arrestor. – Clean spark arrestor.
Generator cannot supply enough power or overheating.|
- Generator is overloaded. – Review load and adjust. See “Connecting Electrical Loads.”
- Dirty air filter. – Clean or replace air filter.
- Choke in wrong position. – Move choke until it stops under RUN position or push in completely.
Engine is running but no AC output.|
- Poor cord connection. – Check all connections.
- Circuit breaker is open. – Reset circuit breaker.
- Loose wiring. – Inspect and tighten wiring connections.
- AC Overload: Button illuminated red – Reduce AC load and press Overload Reset Button until illuminated green.
Engine hunts or falters.|
- Other. – Contact the help line.
- Engine governor defective. – Contact the help line.
- Dirty fuel valve. – Clean the fuel valve.
- Carburetor is dirty and running lean. – Contact the help line.
- Choke in wrong position. – Move choke until it stops under RUN position or push in completely.
DUAL FUEL MODELS ONLY: Engine will not stop.|
- Propane valve is still open. – Turn the propane valve to the CLOSED position on the tank.
Repeated circuit breaker tripping.|
- Overload. – Review load and adjust. See “Connecting Electrical Loads.”
- Faulty power cords or device. – Check for damaged, bare or frayed wires. Replace defective device.
- Circuit breaker still too hot. – Let unit sit for 5 mins.
For other issues and technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
Specifications
Model | 100900 |
---|---|
Power Output | 2000W |
Fuel Type | Dual Fuel |
FAQ (Frequently Asked Questions)
Where can I get technical support for my generator?
What should I do if the AC overload button is illuminated red?
Check if the engine is hunting or faltering. If not, there may be other issues like a defective engine governor, dirty fuel valve, dirty carburetor, or choke in the wrong position.
Why does the engine shut down during operation?
The engine may shut down due to a low oil level or a clogged spark arrestor.
What should I do if my generator won't start?
Check for common issues such as no fuel, a faulty spark plug, or a low oil level, and follow the corresponding solutions provided in the troubleshooting guide.
How can I prevent my generator from shutting down during operation?
Ensure the oil level is proper and the spark arrestor is clean. Place the generator on a flat, level surface.
Who do I contact for technical support if the troubleshooting guide does not resolve my issue?