Champion Power Equipment 100813 Electric Start Generator Instruction Manual
- June 15, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
- 100813 Electric Start Generator
- Specifications
- Generator Specifications:
- Engine Specifications:
- Oil Specifications:
- Fuel Specifications:
- Battery Specifications:
- Temperature Specifications:
- Product Usage Instructions
- Introduction
- Safety Definitions
- Important Safety Instructions
- Controls and Features
- Assembly
- Unpacking
- Install the Wheel Kit
- Connect the Battery
- Add Engine Oil
- Add Fuel
- Grounding
- Q: Where can I register my product?
- Q: Are the specifications subject to change?
- Q: How do I keep my family safe from carbon monoxide?
- Q: What should I do if I experience symptoms of carbon monoxide
100813 Electric Start Generator
Specifications
Generator Specifications:
- Model: 100813
- Power Output: 7500W
- Start Type: Electric Start
Engine Specifications:
- Manufacturer: Champion Power Equipment, Inc.
- Location: Santa Fe Springs, CA, USA
Oil Specifications:
- Type: Engine oil
Fuel Specifications:
- Type: Gasoline
Battery Specifications:
- Type: Rechargeable battery
Temperature Specifications:
- Operating Temperature: N/A
Product Usage Instructions
Introduction
The Champion Power Equipment Model #100813 7500W Electric Start
Generator is a portable power source designed to provide
electricity in remote locations or during power outages. This user
manual contains important safety precautions and instructions for
proper usage of the generator.
Safety Definitions
Before operating the generator, it is crucial to understand the
following safety definitions:
-
Carbon Monoxide (CO): A colorless, odorless
gas that can be deadly if inhaled in high concentrations. -
Carbon Monoxide Detectors: Devices that can
detect the presence of carbon monoxide in the air. -
Generator: The main unit responsible for
generating electricity. -
Control Panel: The interface that allows users
to control and monitor the generator’s functions.
Important Safety Instructions
It is essential to read and follow these safety instructions
before operating the generator:
-
Take your generator outside to prevent carbon monoxide
buildup. -
Educate yourself about carbon monoxide risks to protect your
family. -
Always read the operator’s manual first for proper usage
guidelines. -
Be aware of the symptoms of carbon monoxide poisoning.
-
Install carbon monoxide detectors in your living areas.
-
Keep the generator outside and away from doors, windows, and
garages. -
If you experience symptoms of carbon monoxide poisoning, leave
the area immediately. -
Ensure that fumes from the generator are directed away from
nearby people.
Controls and Features
The generator comes with the following controls and
features:
-
Generator: The main unit responsible for
generating electricity. -
Control Panel: Allows users to control and
monitor the generator’s functions, such as starting and stopping,
voltage regulation, and fuel level. -
Tools Needed: A list of tools required for
assembly and maintenance of the generator.
Assembly
Follow these steps to assemble the generator:
Unpacking
- Remove all packaging materials from the generator.
Install the Wheel Kit
- Attach the provided wheel kit to the generator for easy
transportation.
Connect the Battery
- Connect the rechargeable battery to the generator following the
provided instructions.
Add Engine Oil
- Fill the engine with the recommended type of engine oil as
specified in the user manual.
Add Fuel
- Fill the fuel tank with gasoline according to the user manual’s
instructions.
Grounding
- Properly ground the generator to prevent electrical
hazards.
Operation
Follow these guidelines for operating the generator:
-
Ensure that the generator is placed on a stable and level
surface. -
Turn the fuel valve to the “ON” position.
-
Follow the instructions on the control panel to start the
generator. -
Monitor the control panel for information on voltage output,
fuel level, and other indicators. -
To turn off the generator, follow the provided shutdown
procedure.
Maintenance
Regular maintenance is crucial for optimal performance and
longevity of the generator. Refer to the user manual for detailed
maintenance instructions.
Storage
If the generator will not be used for an extended period, follow
these storage guidelines:
-
Drain the fuel tank and run the generator until it shuts off to
prevent fuel-related issues. -
Store the generator in a cool, dry place away from direct
sunlight and moisture. -
Cover the generator with a protective cover to prevent dust and
debris accumulation.
FAQ
Q: Where can I register my product?
A: You can register your product online at
championpowerequipment.com or visit championpowerequipment.com for
more information.
Q: Are the specifications subject to change?
A: Yes, specifications, descriptions, and illustrations in this
manual are subject to change without notice.
Q: How do I keep my family safe from carbon monoxide?
A: Take your generator outside, educate yourself about carbon
monoxide risks, install carbon monoxide detectors, and keep the
generator away from living areas.
Q: What should I do if I experience symptoms of carbon monoxide
poisoning?
A: Leave the area immediately and seek fresh air. Contact
emergency services for medical assistance.
OPERATOR’S MANUAL
MODEL #100813 7500W ELECTRIC START GENERATOR
REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com
or visit championpowerequipment.com
READ AND SAVE THIS MANUAL. This manual contains important safety precautions
which should be read and understood before operating the product. Failure to
do so could result in serious injury. This manual should remain with the
product.
Specifications, descriptions and illustrations in this manual are as accurate
as known at the time of publication, but are subject to change without notice.
REV 20220701
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
CARBON MONOXIDE KILLS
CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator
outside is absolutely mandatory to keep your family safe from carbon monoxide.
But there’s even more you can do. By educating yourself about all carbon
monoxide risks, you’ll be better prepared to protect your family from this
colorless, oderless threat.
ALWAYS READ MANUAL THE OPERATOR’S
MANUAL FIRST
KNOW THE SYMPTOMS
· Headache
· Dizziness
· Nausea
· Fatigue
· Shortness of breath
STAY ALERT WITH CARBON MONOXIDE DETECTORS
KEEP IT OUTSIDE AND AWAY FROM DOORS, WINDOWS, AND GARAGES
IF YOU FEEL SYMPTOMS, LEAVE RIGHT AWAY
POINT FUMES AWAY FROM NEARBY PEOPLE
www.TakeYourGeneratorOutside.com
100813 – 7500W ELECTRIC START GENERATOR
TABLE OF CONTENTS
Introduction………………………………………… 4 Safety Definitions ………………………………… 4 Important
Safety Instructions ……………….. 5
Fuel Safety ……………………………………………… 7 Safety Labels……………………………………………. 8 Safety
Symbols………………………………………….. 9 Operation Symbols ……………………………………… 10 Quick Start
Label Symbols………………………………. 11
Controls and Features …………………………. 12
Generator ………………………………………………. 12 Control Panel …………………………………………… 13 Tools
Needed …………………………………………… 14
Assembly …………………………………………… 15
Unpacking ……………………………………………… 15 Install the Wheel Kit…………………………………….. 15
Connect the Battery…………………………………….. 15 Add Engine Oil………………………………………….. 16 Add
Fuel ……………………………………………….. 17 Grounding ……………………………………………… 18
Operation …………………………………………… 18
Generator Location……………………………………… 18 Surge Protection ……………………………………….. 19
Starting the Engine……………………………………… 19 Connecting Electrical Loads
…………………………….. 20 Do Not Overload Generator ……………………………… 21
GFCI……………………………………………………. 21 Stopping the Engine…………………………………….. 22 Operation
at High Altitude ……………………………….22
TABLE OF CONTENTS
Maintenance ……………………………………… 23
Cleaning the Generator ………………………….. …….. 23 Changing the Engine Oil
…………………………. …….. 23 Cleaning and Adjusting the Spark Plug(s) ………………… 24
Cleaning the Air Filter ……………………………. …….. 24 Cleaning the Spark Arrestor
…………………………….. 24 Adjusting the Governor………………………………….. 24 Generator Battery
………………………………………. 25 Maintenance Schedule………………………………….. 25
Storage …………………………………………….. 25
Short Term Storage (up to 30 days) ………………. …….. 25 Mid Term Storage (30 days
1 year) …………….. …….. 26 Long Term Storage (over 1 year) …………………. …….. 26
Removing from Storage…………………………………. 26
Specifications……………………………………. 27
Generator Specifications…………………………. …….. 27 Engine Specifications …………………………….
…….. 27 Oil Specifications………………………………… …….. 27 Fuel Specifications
………………………………. …….. 27 Battery Specifications……………………………. …….. 27 Temperature
Specifications………………………. …….. 27
Troubleshooting…………………………………. 28 Warranty* …………………………………………. 29
Warranty Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 29 Repair/Replacement Warranty……………………………29 Do Not
Return The Unit To The Place Of Purchase ………..29 Warranty Exclusions
…………………………………….29 Other Exclusions ………………………………… ……..29 Limits of Implied
Warranty and Consequential Damage……29 Contact Information ……………………………………..29
3
100813 – 7500W ELECTRIC START GENERATOR
INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product.
CPE designs, builds, and supports all of our products to strict specifications
and guidelines. With proper product knowledge, safe use, and regular
maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the
information in this manual at the time of publication, and we reserve the
right to change, alter and/or improve the product and this document at any
time without prior notice.
Since CPE highly values how our products are designed, manufactured, operated
and are serviced, and also highly value your safety and the safety of others,
we would like you to take the time to review this product manual and other
product materials thoroughly and be fully aware and knowledgeable of the
assembly, operation, dangers and maintenance of the product before use. Fully
familiarize yourself, and make sure others who plan on operating the product
fully familiarize themselves too, with the proper safety and operation
procedures before each use. Please always exercise common sense and always err
on the side of caution when operating the product to ensure no accident,
property damage, or injury occurs. We want you to continue to use and be
satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the
complete model and serial numbers of your product. Transcribe the information
found on your product’s nameplate label to the table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100813
SERIAL NUMBER
INTRODUCTION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible
dangers. The safety symbols, and their explanations, deserve your careful
attention and understanding. The safety warnings do not by themselves
eliminate any danger. The instructions or warnings they give are not
substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which,if not avoided, will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
DATE OF PURCHASE
PURCHASE LOCATION
4
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous
gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST
AWAY. DO NOT operate the generator inside any building, including garages,
basements, crawlspaces and sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to
enter a confined area through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains
carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a
home or garage, EVEN IF doors and windows are open. ONLY use OUTSIDE and far
away from windows, doors, and vents.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide
alarms with battery back-up according to the manufacturer’s instructions.
IMPORTANT SAFETY INSTRUCTIONS
DANGER
Operate equipment with guards in place. Rotating parts can entangle hands,
feet, hair, clothing and/or accessories. Traumatic amputation or severe
laceration can result.
Keep hands and feet away from rotating parts. Tie up long hair and remove
jewelry. DO NOT wear loose-fitting clothing, dangling drawstrings or items
that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles. DO NOT use electrical cords that are
worn, damaged or frayed. Use only Champion electrical cords for proper
application. DO NOT operate generator in wet weather. DO NOT allow children or
unqualified persons to operate or service the generator. Use a ground fault
circuit interrupter (GFCI) in damp areas and areas containing conductive
material such as metal decking. Connection to your home’s electrical system
requires a listed 30A transfer switch installed by a licensed electrician and
approved by the local authority having jurisdiction. The connection must
isolate the generator from the utility power and must comply with all
applicable laws and electrical codes.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately. NEVER use this product to power
life support devices or life support appliances. NEVER use this product to
power medical devices or medical appliances. Inform your electricity provider
immediately if you or anyone in your household depends on electrical equipment
to live. Inform your electrical provider immediately if a loss of power would
cause you or anyone in your household to experience a medical emergency.
5
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator: Disconnect the spark plug wire and place it
where it cannot contact the plug or any other metal object. DO NOT check for
spark with the plug removed. Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible
material can catch fire on contact.
DO NOT touch hot surfaces. Avoid contact with hot exhaust gases. Allow
equipment to cool before touching. Maintain at least 3 ft. (91.4 cm) of
clearance on all sides to ensure adequate cooling. Maintain at least 5 ft.
(1.5 m) of clearance from combustible materials.
WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine
faster than you can let go. Broken bones, fractures, bruises or sprains could
result. Unintentional startup can result in entanglement, traumatic amputation
or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt and
then pull rapidly to avoid kickback. DO NOT start or stop the engine with
electrical devices plugged in and turned on.
CAUTION
Start the generator and allow the engine to stabilize before connecting
electrical loads. Connect electrical equipment in the off position, and then
turn them on for operation. Turn electrical equipment off and disconnect
before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or
void the warranty.
Use the generator only for intended uses. Operate only on level surfaces. DO
NOT expose generator to excessive moisture, dust, or dirt. DO NOT allow any
material to block the cooling slots. If connected devices overheat, turn them
off and disconnect them from the generator. DO NOT use the generator if:
Electrical output is lost Equipment sparks, smokes or emits flames
Equipment vibrates excessively
WARNING
Although the generator contains a spark arrester, maintain a minimum distance
of 5 ft. (1.5 m) from dry vegetation to prevent fires.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or
electrical devices connected to it. DO NOT overload the generator. DO NOT
tamper with the governed speed. DO NOT modify the generator in any way.
6
100813 – 7500W ELECTRIC START GENERATOR
Fuel Safety
DANGER
GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors: Gasoline is highly flammable and explosive.
Gasoline can cause a fire or explosion if ignited. Gasoline is a liquid fuel
but it’s vapors can ignite. Gasoline is a skin irritant and needs to be
cleaned up
immediately if spilled on skin or clothes. Gasoline has a distinctive odor,
this will help detect potential
leaks quickly. Gasoline expands or contracts with ambient temperatures.
Never fill the gasoline tank to full capacity, as gasoline needs room to
expand when temperatures rise. In the case of any petroleum gasoline fire,
flames should never be extinguished unless the fuel supply valve can be turned
OFF. By not doing so, if a fire is extinguished and the supply of fuel is not
turned OFF, an explosion hazard could be created. When adding or removing
gasoline: DO NOT light or smoke cigarettes. Turn the generator off and let
cool for at least two minutes before removing the gasoline cap. Always loosen
the cap slowly to relieve pressure in the tank. Only fill or drain gasoline
outdoors in a well-ventilated area. DO NOT pump gasoline directly into the
generator at the gas station. Always use an approved container to transfer the
fuel to the generator. DO NOT overfill the gasoline tank. Always keep gasoline
away from sparks, open flames, pilot lights, heat and other sources of
ignition. When starting the generator: DO NOT attempt to start a damaged
generator. Always check that the gasoline cap, air filter, spark plug, fuel
lines and exhaust system are properly in place. Always allow spilled gasoline
to evaporate fully before attempting to start the engine. Always be certain
that the generator is resting firmly on level ground.
IMPORTANT SAFETY INSTRUCTIONS
When operating the generator: DO NOT move or tip the generator during
operation. When transporting or servicing the generator: Always check that the
fuel valve is in the OFF position and the gasoline tank is empty. Disconnect
the spark plug wire. When storing the generator: Store away from sparks, open
flames, pilot lights, heat and other sources of ignition. Do not store
generator or gasoline near furnaces, water heaters, or any other appliances
that produce heat or have automatic ignitions.
DANGER
NEVER place a gasoline container, gasoline tank, LPG cylinder or any
combustible material in the path of the exhaust stream during operation of the
engine.
WARNING
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
7
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety Labels
These labels warn you of potential hazards that can cause serious injury. Read
them carefully. If a label comes off or becomes hard to read, contact
Technical Support Team for possible replacement.
D
A
C
B
Top LABEL
Back DESCRIPTION
A
1028-L-SF-E
DANGER
PELIGRO
DANGER
Using a generator indoors CAN KILL El uso de un generador en
Utiliser une génératrice à l’intérieur
YOU IN MINUTES. Generator exhaust interiores PUEDE MATARLO EN PEUT VOUS TUER EN QUELQUES
contains carbon monoxide. This is a MINUTOS. El escape del
MINUTES. L’échappement de la
poison you cannot see or smell.
generador contiene monóxido de génératrice contient du monoxyde de
carbono. Éste es un veneno que no carbone. Il s’agit d’un poison que vous
se puede ver ni oler.
ne pouvez ni voir ni sentir.
· NUNCA lo use dentro del hogar ni · Ne l’utilisez JAMAIS dans la
el garaje, INCLUSO SI las puertas maison ou le garage MÊME SI les
NEVER use inside a ONLY use OUTSIDE y ventanas están abiertas.
home or garage, and far away from · Úselo SÓLO a la INTEMPERIE
EVEN IF doors and windows, doors, lejos de ventanas, puertas, y
windows are open. and vents.
orificios de ventilación.
portes et les fenêtres sont ouvertes. · Utilisez la UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes et trappes de ventilation.
UNLEADED FUEL ONLY. Minimum octane rating of 87. Maximum 10% ethanol.
B
GASOLINA REGULAR SOLAMENTE. 87 octanos como mínimo. Máximo de etanol de 10%.
ESSENCE SANS PLOMB SEULEMENT. Indice d’octane minimal de 87. Maximum 10 % d’éthanol.
WARNING
ADVERTENCIA
C
DO NOT TOUCH!
Operation of this equipment may create sparks that can start ¡NO TOCAR! Los gases de
Exhaust gases, muffler fires around dry vegetation. A spark arrestor may be
escape, el silenciador y los
La operación de este equipo puede producir chispas que pueden provocar incendios alrededor de la vegetación seca. Un supresor de chispas puede que
and engine components required. The operator should contact local fire agencies for compnonentes del motor están sea necesario. El operador debe comunicarse con las agencias locales de
are extremely HOT and laws and regulations relating to fire prevention requirements. extremadamente CALIENTES y bomberos para las leyes y reglamentos relativos a los requisitos de prevención
cause burns.
If installed, clean every 100 hours or every season.
causan quemaduras.
de incendios. Si está instalado, limpie cada 100 horas o cada temporada.
CHAMPION POWER EQUIPMENT, INC.
12039 SMITH AVENUE SANTA FE SPRINGS, CA 90670 USA / É.-U.
1-877-338-0999
FREQUENCY (Hz) FRÉQUENCE (Hz)
RPM TR / MIN
60 3600
MAX AMBIENT TEMP. 104°F TEMP. AMBIANTE MAX. 40°C
H INSULATION CLASS
CLASSE D’ISOLATION
D
WWW.CHAMPIONPOWEREQUIPMENT.COM MADE IN CHINA / FABRIQUÉ EN CHINE
PHASE PHASE
1
MODEL MODÈLE
100813
POWER FACTOR FACTEUR DE PUISSANCE
1.0
GASOLINE WATTS WATTS D’ESSENCE
7500
SERIAL NO. N° DE SÉRIE
XXXXXXXXXXXX
AC VOLTS VOLTS C.A.
120/240
XXXX MANUFACTURE DATE
DATE DE FABRICATION
AC AMPS AMPÈRES C.A.
62.5/31.3
8
3536-L-PR-A 1032-L-OP-B
1291-L-SF-A
Safety Icons/ CO Danger
Fuel Hot Surface
Dataplate
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL
MEANING
Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product.
Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat from the muffler and exhaust gas can ignite combustible objects.
Ground. Consult with local electrician to determine grounding requirements
before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices
can result in electric shock. Improper connections to a building can allow
current to backfeed into utility lines, creating an electrocution hazard. A
transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death. Keep generator at least 5
feet (1.5m) from all objects to prevent combustion.
Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.
Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from smoking, open flames, sparks, pilot lights, heat, and other ignition sources.
Wet Conditions Alert. Do not expose to rain or use in damp locations.
9
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Operation Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL
Start
MEANING
On
Stop or Off
Neutral Bonded to Frame. Neutral circuit IS electrically connected to the
frame/ground of the generator.
Locking Receptacle
Circuit Breaker Reset: Push
Fuel/Gasoline Valve On/Off
SYMBOL
Choke
MEANING
Run
Ground Terminal
10
100813 – 7500W ELECTRIC START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
1
2
10W-30
3
4
5
6
7
8
1
2
3
3109-L-OP-B
Starting the Engine
DANGER
Move generator outside and far away from windows, doors and intake ventilation
covers.
1. Check oil level. Recommended oil is 10W-30.
2. Check gasoline level. When adding gasoline, use a minimum octane rating of
87 and an ethanol content of 10% or less by volume.
3. Turn the fuel valve to “ON” position. 4. Press ignition switch to the “ON”
position. 5. Move choke lever to “CHOKE” position. 6. Pull the recoil cord. 7.
Move the choke lever to “RUN” position. 8. Plug in desired device.
Stopping the Engine 1. Turn off and unplug all connected electrical loads. 2. Press the ignition switch to the “OFF” position. 3. Turn the fuel valve to the “OFF” position. Electric Start See page 18 in “Operation” section.
11
100813 – 7500W ELECTRIC START GENERATOR
CONTROLS AND FEATURES
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize
yourself with the location and function of the controls and features. Save
this manual for future reference.
Generator
1
2 3
4 5
6
11 10
8
9
7
1. Gasoline Tank 5.7 gal. (21.5 L) 2. Choke Used to start the engine. 3.
Fuel Valve Used to turn fuel supply on and off to engine. 4. Air Filter
Protects the engine by filtering dust and debris
from the intake air. 5. Recoil Starter Used to manually start the engine. 6.
Never Flat Wheels 9.5 in. (24.1 cm) 7. Oil Fill Cap/Dipstick Used to check
and fill oil level.
8. Battery Provides 12V DC power the starting system.
9. Ground Terminal Consult an electrician for local grounding regulations.
10. Control Panel See “Control Panel” section.
11. Folding Handle Used to move unit by lifting and rolling on wheels. Do
not use to lift or carry the unit.
12
100813 – 7500W ELECTRIC START GENERATOR
Control Panel
2 1
CONTROLS AND FEATURES
3
B
C
A
1. Ignition Switch Used to START or STOP the generator.
2. Intelligauge Four mode digital meter for displaying voltage, frequency
(hertz), run time, and total run time.
3. Circuit Breakers (Push Reset) Protects the generator against electrical
overloads.
AC
BY CD
RECEPTACLES
(4×) 120V AC, 20A GFCI (NEMA 5-20R) May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical loads.
120/240V AC, 30A Locking (NEMA L14-30R) May be used to supply electrical power
for operation of 120/240 Volt AC, 30 Amp, single phase, 60 Hz electrical
loads.
120/240V AC, 31.3 Amp (NEMA 14-50R) May be used to supply electrical power for
operation of 120/240 Volt AC, 31.3 Amp, single phase, 60 Hz electrical loads.
13
100813 – 7500W ELECTRIC START GENERATOR
Parts Included
Accessories Oil Funnel ………………………………………………….. 1 Engine Oil……………………………………….1.2
qt. (1.1 L)
Assembly Parts Wheels 9.5 in. (24.1 cm) Never Flat Wheel (A) ……………………. 2 Roll
Pin (B) ……………………………………………… 2 Large R-clip (C) …………………………………………. 2 Engine
Vibration Mounts Support Leg with Vibration Mounts (D) …………………… 1 Flange Bolt
(M8×16) (E) …………………………………. 2 Flange Lock Nut (M8) (F) ………………………………… 2 Folding
Handle Handle (G) ………………………………………………. 1 Short Pin (H) ……………………………………………. 2
Small R-clip (I) ………………………………………….. 2
Tools Needed
Wrench/Socket Set (metric) Pliers Phillips Screwdriver
CONTROLS AND FEATURES
A
B
C
D
G
EF
H
I
14
100813 – 7500W ELECTRIC START GENERATOR
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory
without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our
Technical Support Team at
1-877-338-0999. Please have your serial
number and model number available.
Unpacking
1. Set the shipping carton on a solid, flat surface. 2. Remove everything
from the carton except the generator. 3. Carefully cut each corner of the box
from top to bottom. Fold
each side flat on the ground to provide a surface area to work with the
generator.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
ASSEMBLY
E D
F
Install the Handle
1. Place the Handle (G) inside the mounting channel on the frame.
2. Secure the Handle to the frame using an Short Pin (H).
3. Place an R-clip (I) on the end of the Short Pin and fasten securely.
I
H
G
1. Before adding fuel and oil, tip the generator on it’s end. 2. Slide the Roll Pin (B) through the Wheel (A) from the outside. 3. Slide the Roll Pin through the mount point on the frame. 4. Secure with the R-clip (C). 5. Repeat to attach the second Wheel.
C
B
A
Connect the Battery
1. Remove the protective cover from the black () lead on the battery.
2. Attach the black () lead to the () terminal on the battery with the bolt
and secure with the nut.
Install the Support Leg 1. Attach the Support Leg (D) to the generator frame
with Flange
Bolts (E) and Flange Lock Nuts (F). 2. Slowly tip the generator back down so
that it rests on the
Wheels and Support Leg.
15
100813 – 7500W ELECTRIC START GENERATOR
Add Engine Oil
WARNING
DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil. Damage to the generator as a
result of failing to follow these instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no
additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30 automotive oil. However,
using the listed conventional oils shown in the “Recommended Engine Oil Type”
chart may be used for typical use including the first 5 hours of the break-in
run time period of the engine. If running generator in extreme temperatures,
refer to the “Recommended Engine Oil Type” chart.
Recommended Engine Oil Type 10W-30
5W-30
10W-40
5W-30 Full Synthetic
°F -20
0
20 40 60 80 100 120
°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
Ambient temperature
1. Place the generator on a flat, level surface. 2. Remove oil fill
cap/dipstick to add oil. 3. Using a funnel, add up to 1.2 qt. (1.1 L) of oil
(included) and
replace oil fill cap/dipstick. DO NOT OVERFILL.
ASSEMBLY
MAX OIL DIP STICK
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. When using the dipstick to check oil level, DO
NOT screw in the dipstick while checking.
NOTICE
Check oil level often during the break-in period. Refer to the Maintenance
section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil
level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the
break in period stay at or below 50% of the running watt rating and vary the
load occasionally to allow stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using
synthetic oil does not decrease the recommended oil change interval. Full
synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C)
temperatures.
4. Check engine oil level daily and add as needed.
16
100813 – 7500W ELECTRIC START GENERATOR
Add Fuel DANGER
Gasoline vapors are highly flammable and extremely explosive. DO NOT light or
smoke cigarettes. Fire or explosion can cause severe burns or death. Only fill
or drain fuel outdoors in a well-ventilated area. DO NOT pump gasoline
directly into the generator. Use an approved container to transfer the fuel to
the generator. Never use a gasoline container, gasoline tank, or any other
fuel item that is broken, cut, torn or damaged. DO NOT overfill the gasoline
tank. Always keep fuel away from sparks, open flames, pilot lights, heat and
other sources of ignition.
Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87
and an ethanol content of 10% or less by volume. y b c DO NOT mix oil with
gasoline. 1. Remove the gasoline cap. 2. Slowly add gasoline to the tank. Tank
is full when gasoline
reaches red circle on screen. DO NOT OVERFILL. Gasoline can expand after
filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for
gasoline expansion, although more than ¼ in. (6.4 mm) is recommended. Gasoline
can be forced out of the tank as a result of expansion if overfilled, and can
affect the stable running condition of the generator.
3. Screw on the gasoline cap and wipe away any spilled fuel.
ASSEMBLY
CAUTION
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol
content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank. DO NOT mix oil and
gasoline. DO NOT overfill the tank. Fill tank to approximately ¼ in. (6.4 mm)
below the top of the tank to allow for gasoline expansion. DO NOT pump
gasoline directly into the generator at the pump. Use an approved fuel
container to transfer the gasoline to the generator. DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result in gasoline
splashing over the generator and operator while filling.
NOTICE
The generator engine works well with 10% or less ethanol blended gasoline.
When using ethanol-gasoline blends there are some issues worth noting:
Ethanol-gasoline blends can absorb more water than
gasoline alone. These ethanol blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and carburetor. The compromised
gasoline can be drawn into the carburetor and cause damage to the engine
and/or create potential hazards. If a fuel stabilizer is used, confirm that
it is formulated to work with ethanol-gasoline blends. Any damages or
hazards caused by using ethanol blended gasoline higher than 10% by volume,
improperly stored gasoline, and/or improperly formulated stabilizers, are not
covered by manufacturer’s warranty. It is advisable to always shut off the
gasoline supply and run the engine to starvation after each use. See Storage
instructions for extended non-use.
17
100813 – 7500W ELECTRIC START GENERATOR
Grounding
Your generator must be properly connected to an appropriate ground to help
prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the frame of the generator has been provided
(see Controls and Features for terminal location). For remote grounding,
connect a length of heavy gauge (12 AWG minimum) copper wire between the
generator ground terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure compliance
with local electrical codes.
Neutral Floating
Neutral circuit IS NOT electrically connected to the frame/ ground of the
generator.
The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
Electrical devices that require a grounded receptacle pin connection will
not function if the receptacle ground pin is not functional.
Neutral Bonded to Frame
Neutral circuit IS electrically connected to the frame/ground of the
generator.
The generator system ground connects lower frame crossmember below the
alternator. The system ground is connected to the AC neutral wire.
- See your Specifications section for specified type of grounding.
OPERATION
OPERATION
Generator Location
WARNING
NEVER operate the generator inside any building, garage, basement, crawlspace,
shed, enclosure or compartment, including a generator compartment of a
recreational vehicle.
NEVER operate or start the generator in the back of an SUV, camper, trailer,
truck bed (regular sides, flat or other configuration), under staircases,
stairwells, next to walls or buildings or in any other location that will not
allow for adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather conditions such as rain
or snow. Using a generator in wet conditions could result in serious injury or
death due to electrocution.
In some state’s generators may be required to be registered with the local
utility company when used at construction sites and may be subject to
additional rules and regulations, consult your local municipal authority.
Generators should always be operated on a flat, level surface at all times
(even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of clearance from all
combustible material.
Generators must also have a minimum of 3 feet (91.4 cm) of air flow clearance
on all sides to allow for adequate performance cooling, maintenance and
servicing.
Always place the generator in a well-ventilated area. NEVER place the
generator near air intake vents or where exhaust fumes could be drawn into
occupied or confined spaces.
Always carefully consider wind and air currents when positioning generator.
Always allow generators to properly cool before transport or for storage
purposes.
Failure to follow proper safety precautions may result in personal injury,
damage to the generator and void the manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become hot. If adequate
cooling and breathing space are not supplied, or if the generator is blocked
or enclosed, temperatures can become extremely heated and may lead to fire.
18
100813 – 7500W ELECTRIC START GENERATOR
WARNING
Do not expose to rain or use in damp locations. Keep all objects a minimum of
5 feet (1.5m) away from the generator at all times. Heat from the muffler
surface and exhaust gas stream can ignite combustible materials.
OPERATION
Electric Start 1. Move the choke to the “CHOKE” position.
1a. For restarting a warm engine, move the choke to 75% of the “CHOKE”
position.
WARNING
If you must operate in rain or damp locations, DO NOT operate without proper
protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air
ventilation for the engine exhaust gas stream may be used.
Visit championpowerequipment.com or call to find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use
components that are designed to operate within a narrow voltage range and may
be affected by momentary voltage fluctuations. While there is no way to
prevent voltage fluctuations, you can take steps to protect sensitive
electronic equipment.
Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding
your sensitive equipment. Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually all short-duration
voltage fluctuations.
Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start or stop
the generator with electrical devices plugged in or turned on.
3. Turn the gasoline fuel valve to the “ON” position.
2. Press and hold the ignition switch to the “START” position. Release as the
engine begins to start. If the engine fails to start within five seconds,
release the switch and wait at least ten seconds before attempting to start
the engine again.
CAUTION
If the ignition switch is held down in the “START” position longer than 5
seconds it could damage the starter. 3. Do not over-choke. As soon as engine
starts, move the choke
to the “RUN” position over a 2-5 second duration.
19
100813 – 7500W ELECTRIC START GENERATOR Manual Start 1. Push the ignition
switch to the “ON” position.
2. Move the choke to the “CHOKE” position. 2a. For restarting a warm engine,
move the choke to 75% of the “CHOKE” position.
3. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
OPERATION
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke to “RUN” position for up to 3 pulls of the recoil cord. Too
much choke leads to spark plug fouling/engine flooding due to lack of incoming
air. This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient > 86°F (30°C), keep choke
in 75% of the “CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke to “RUN” position for up to 3 pulls of the recoil cord. Too
much choke leads to spark plug fouling/engine flooding due to lack of incoming
air. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F (15°C), the choke
must be in 100% of the “CHOKE” position for manual start procedures. Do not
over-choke. As soon as engine starts, gradually move the choke lever to the
“RUN” position over a 2-5 second duration.
NOTICE
If the engine starts but does not run make certain that the generator is on a
flat, level surface. The engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level falls below a critical
threshold.
4. Do not over-choke. As soon as engine starts, move the choke to the “RUN” position over a 2-5 second duration.
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC single
phase, 60 Hz electrical loads.
DO NOT connect 3-phase loads to the generator.
DO NOT overload the generator.
Use only a high quality, insulated, compatible (3-wire or 4-wire) grounded
cord set rated equal to or greater (volts and amps) than the receptacle
plugging into.
20
100813 – 7500W ELECTRIC START GENERATOR
OPERATION
WARNING
Always remember to plug your appliances directly into the generator and do not
plug the generator power cord into any electrical outlet or connect to the
circuit breaker panel in your home. Connecting a generator to your home’s
electric utility company’s power lines, or to another power source, called
`backfeeding’ is a dangerous practice that is illegal in many states and
municipalities.
This action if done incorrectly could damage your generator, appliances and
could cause serious injury or death to you or a utility worker when attempting
to restore power during an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and suffer a fatal
shock.
Whether injuries occur or not, if installed incorrectly and not to applicable
laws and codes, you may be subject to fines or the utility company may
disconnect your home power should this practice be found in your home.
If the generator will be connected to a building electrical system, those
connections must isolate the generator power from the utility power. You are
responsible for ensuring your generator’s electricity does not backfeed into
the electric utility power lines. These connections must comply with all
applicable laws and codes Consult your local utility company or a qualified
electrician to properly install this connection.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts
necessary for your purposes:
1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you
need to keep your items running.
3. Identify the highest starting wattage of all devices identified in step 1.
Add this number to the number calculated in step 2. Starting wattage is the
extra burst of power needed to start some electric driven equipment. Following
the steps listed under “Power Management” will guarantee that only one device
will be starting at a time.
Power Management
Use the following formula to convert voltage and amperage to watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow these steps
to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to get up to temperature.
3. Make sure all circuit breakers are set to the run position. 4. Plug in and
turn on the first item. It is best to attach the item
with the largest load first. 5. Allow the engine to stabilize. 6. Plug in and
turn on the next item. 7. Allow the engine to stabilize. 8. Repeat steps 5-6
for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.
GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI)
receptacles. In the event of a ground fault, a GFCI trips automatically to
stop the flow of electricity and prevent serious injury. The green indicator
light (A) on the receptacle will also turn off. Press the “RESET” (B) button
located on the front of the receptacle to restore flow of electricity. The
indicator light will also turn back on. GFCI does not protect against circuit
overloads. To ensure proper operation of the GFCI duplex, perform this test
monthly: 1. With the generator running, plug a lamp into the GFCI
receptacle. Turn the lamp on. 2. Press the “TEST” (C) button located on the
front of the
receptacle to trip the device. This should immediately stop the flow of
electricity and shut off the lamp. If the electricity is not stopped, do not
use this receptacle until it has been serviced or replaced. 3. Press the
“RESET” button located on the front of the receptacle to restore the flow of
electricity. If the indicator light does not come back on or if the GFCI
cannot be reset then it must be replaced.
A
B C
21
100813 – 7500W ELECTRIC START GENERATOR
NOTICE
In any electrical application, some current will flow through the protective
ground conductor to the ground, this is called leakage current. It takes 4 mA
(0.004 A) and higher of leakage current from the hot wire to the ground to
cause a GFCI to trip. On circuits protected by GFCI’s, leakage current can
cause unnecessary and intermittent tripping. Some stationary motors, such as a
bathroom vent fan, fluorescent lighting fixtures or some refrigerators, may
produce enough leakage to cause nuisance tripping. To avoid nuisance tripping,
a GFCI should not supply: Fluorescent or other types of electric-discharge
lighting
fixtures. Permanently installed electric motors, like air conditioners,
furnaces or refrigerators.
Stopping the Engine
1. Turn off and unplug all connected electrical loads. Never start or stop
the generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to stabilize internal
temperatures of the engine and generator.
3. Press the ignition switch to the “OFF” position.
4. Turn the fuel valve to the “OFF” position.
OPERATION
Important: Always ensure that the fuel valve and the ignition switch are in
the “OFF” position when the generator is not in use.
NOTICE
If the engine will not be used for a period of two (2) weeks or longer, please
see the Storage section for proper engine and fuel storage.
Operation at High Altitude
The density of air at high altitudes is lower than at sea level. Engine power
is reduced as the air mass and air-fuel ratio decrease. Engine power and
generator output will be reduced approximately 3½% for every 1000 ft. of
elevation above sea level. At high altitudes increased exhaust emissions can
also result due to the increased enrichment of the air fuel ratio. Other high
altitude issues can include hard starting, increased fuel consumption and
spark plug fouling.
To alleviate high altitude issues other than the natural power loss, CPE can
provide a high altitude carburetor main jet. The alternative main jet and
installation instructions can be obtained by contacting our Technical Support
Team. Installation instructions are also available in the Technical Bulletin
area of the CPE website.
The part number and recommended minimum altitude for the application of the
high altitude carburetor main jet is listed in the following table.
In order to select the correct high altitude main jet it is necessary to
identify the carburetor model. For this purpose, a code is stamped on the side
of the carburetor. Select the correct high altitude jet part number
corresponding to the carburetor code found on your particular carburetor.
Carb. Code High Alt. Jet Part Number
Z950-1
100155681 100062835
Min. Altitude
3281 ft. (1000 m) 6562 ft. (2000 m)
WARNING
Operation using the alternative main jet at elevations lower than the
recommended minimum altitude can damage the engine. For operation at lower
elevations, the originally supplied standard main jet must be used. Operating
the engine with the wrong engine configuration at a given altitude may
increase its emissions and decrease fuel efficiency and performance.
22
100813 – 7500W ELECTRIC START GENERATOR
MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only
operate the unit on a flat, level surface in a clean, dry operating
environment. DO NOT expose the unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.
WARNING
Improper maintenance will void your warranty.
NOTICE
Maintenance, replacement, or repair of emission control devices and systems
may be performed by any non-road engine repair establishment or individual.
The owner/operator is responsible for all periodic maintenance. Complete all
scheduled maintenance in a timely manner. Correct any issue before operating
th e generator. For service or parts assistance, contact our Technical Support
Team at 1-877-338-0999.
Cleaning the Generator
CAUTION
DO NOT spray engine with water. Water can enter the generator through the
cooling slots and damage the generator windings. It can also contaminate the
fuel system.
1. Use a damp cloth to clean exterior surfaces of the generator. 2. Use a
soft bristle brush to remove dirt and oil. 3. Use an air compressor (25 PSI)
to clear dirt and debris from
the generator. 4. Inspect all air vents and cooling slots to ensure that they
are
clean and unobstructed. To prevent accidental starting, remove and ground the
spark plug wire before performing any service.
MAINTENANCE Changing the Engine Oil
Change oil when the engine is warm. Refer to the oil specification to select
the proper grade for your operating environment. 1. Remove the oil drain bolt
with a 12 mm socket
(not included) and extension.
DRAIN BOLT 2. Allow the oil to drain completely into an appropriate container.
3. Replace the oil drain bolt. 4. Add oil according to Add Engine Oil in
Assembly section.
DO NOT OVERFILL. Oil not included for routine maintenance. 5. Dispose of used
oil at an approved waste management
facility.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. If using the dipstick to check oil level, DO NOT
screw in the dipstick while checking.
23
100813 – 7500W ELECTRIC START GENERATOR
Cleaning and Adjusting the Spark Plug(s)
1. Remove the spark plug cable from the spark plug. 2. Use a spark plug
socket tool (not included), or a
13/16 in. (21 mm) socket (not included) to remove the plug. 3. Inspect the
electrode on the plug. It must be clean and not
worn to produce the spark required for ignition. 4. Make certain the spark
plug gap is
0.024-0.031 in. (0.6-0.8 mm).
MAINTENANCE
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark arrestor.
2. Remove the two or three screws (varies by model) holding the cover plate
which retains the spark arrestor to the muffler.
3. Remove the spark arrestor screen. 4. Carefully remove the carbon deposits
from the spark arrestor
screen with a wire brush.
SPARK PLUG GAP
5. Refer to the spark plug types in Specifications when replacing the plug.
6. Firmly re-install the plug. 7. Attach the spark plug cable to the spark
plug.
Cleaning the Air Filter
1. Remove the snap-on cover holding the air filter to the assembly.
2. Remove the foam element. 3. Wash in liquid detergent and water. Squeeze
thoroughly dry in
a clean cloth. 4. Saturate in clean engine oil. 5. Squeeze in a clean,
absorbent cloth to remove all excess oil. 6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in place.
- See your model’s parts list for specified type of spark arrestor.
5. Replace the spark arrestor if it is damaged. 6. Position the spark arrestor on the muffler and attach with the
screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in degraded engine performance.
NOTICE
Federal and local laws and administrative requirements indicate when and where spark arrestors are required. When ordered, spark arrestors are required for operation of this generator in National Forest lands. In California, this generator must not be used on any forest-covered land, brush-covered land, or grass-covered land unless the engine is equipped with a spark arrestor.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.
The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. Contact our Technical Support Team at 1-877-338-0999 for all other service and/or adjustment needs.
24
100813 – 7500W ELECTRIC START GENERATOR
Generator Battery
Your generator is equipped with an automatic battery charging circuit that
charges the battery while the engine is running. The battery will maintain a
proper charge if the unit is used on a regular basis (about once every two
weeks). If it is used less frequently, the battery should be connected to a
trickle charger or battery maintainer (not included) to keep the battery
properly charged.
Maximum charging rate should not exceed 1.5 amps. Follow the instructions
included with the battery charger. The battery should be fully charged at
least once per month. If the battery is not able to start the engine, it can
be started by manually pulling the engine recoil cord. If the battery voltage
is extremely low, the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a standard automotive
style battery charger for re-charging before it can be used.
Disconnect the Battery
1. Remove the protective cover from the black () battery lead.
2. Disconnect the black () lead from the black () terminal on the battery
and store the cap screw and nut.
3. Repeat steps 1-2 for the red (+) battery lead.
4. Store the battery in a cool, dry place.
Charge the Battery
For a generator equipped with batteries for electric starting, proper battery
maintenance and storage should be followed. A trickle charger or battery
maintainer should be used to charge the battery while the generator is in
storage. Maximum charging rate should not exceed 1.5 amps. Follow the
instructions included with the trickle charger or battery maintainer. The
battery should be fully charged at least once per month.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at
1-877-338-0999 to locate the nearest
CPE certified service dealer for your generator or engine maintenance needs.
EVERY 8 HOURS OR DAILY
Check oil level Clean around air intake and muffler
FIRST 5 HOURS
Change oil
STORAGE
EVERY 50 HOURS OR EVERY SEASON Clean air filter Change oil if operating under
heavy load or in hot
environments
EVERY 100 HOURS OR EVERY SEASON Change oil Clean/adjust spark plug
Check/adjust valve clearance Clean spark arrestor Clean fuel tank and filter
EVERY 250 HOURS Clean combustion chamber
EVERY 3 YEARS Replace fuel line
- To be performed by knowledgeable, experienced owners or CPE certified service centers.
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed: When storing the generator make sure the ignition switch
and fuel valve are set to the “OFF” position.
Short Term Storage (up to 30 days)
Ethanol blended gasoline may gum up and clog the carburetor if the generator is not run or carburetor drained within 4 weeks. 1. Be sure all appliances are disconnected from the generator. 2. Start the generator as instructed in Starting the Engine
section. 3. Turn the fuel valve to the “OFF” position. 4. Let the engine run until fuel starvation has stopped the
engine. This usually takes a few minutes. 5. Move the ignition switch to the “OFF” position.
25
100813 – 7500W ELECTRIC START GENERATOR
Mid Term Storage (30 days 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life of up to 1 year
with the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place. 1. Be sure all appliances are disconnected from the
generator. 2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the “ON” position. 4. Start and run the generator
for 10 minutes so the treated
gasoline cycles through the fuel system. 5. Option 1: Drain Gasoline from
Carburetor
5a. Turn ignition switch to the “OFF” position and allow generator to cool
completely before continuing.
5b. Turn the fuel valve to the “OFF”. 5c. Use the drain bolt on the carburetor
to empty any
excess gasoline from the carburetor into an appropriate container. Use a
funnel (and appropriate hose if necessary) under the carburetor drain bolt to
avoid spillage.
5d. When gasoline stops flowing from the carburetor, replace and tighten the
carburetor drain bolt and be sure to properly dispose of the drained gasoline
according to local regulations or guidelines.
6. Option 2: Run Dry 6a. With the generator running, turn the fuel valve to
the “OFF” position and allow the generator to run until the engine stops from
complete fuel starvation. This may take a few minutes. 6b. Turn ignition
switch to the “OFF” position and allow generator to cool completely before
continuing.
7. Remove the spark plug cap and spark plug and pour about a tablespoon of
oil into the cylinder.
8. Pull the recoil cord slowly to crank the engine to distribute the oil and
lubricate the cylinder.
9. Install the spark plug and spark plug cap. 10. Clean the generator
according to Cleaning the Generator. 11. Store the generator in a cool, dry
place out of direct sunlight.
STORAGE
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must be completely
drained of gasoline.
1. The generator is to be OFF and all appliances disconnected.
2. Turn the fuel valve to the “ON” position.
3. Use the drain bolt on the carburetor to empty any excess gasoline from the
gasoline tank and carburetor into an appropriate container. Use a funnel (and
appropriate hose if necessary) under the carburetor drain bolt to avoid
spillage.
4. When gasoline stops flowing from the carburetor, replace and tighten the
carburetor drain bolt and be sure to properly dispose of the drained gasoline
according to local regulations or guidelines.
5. Turn the fuel valve to the “OFF” position.
6. Follow steps 7-11 according to Mid Term Storage.
Removing from Storage
NOTICE
If the generator has been improperly stored for a period longer than 30 days
with ethanol blended gasoline in the gasoline tank and/or carburetor, all fuel
must be drained and the carburetor must be thoroughly cleaned of ethanol build
up. This process involves technically advanced tasks. For assistance please
call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all ethanol
blended gasoline prior to the generator being stored, follow the below steps
when removing from storage.
1. Be sure the ignition switch is in the “OFF” position.
2. Add gasoline to the generator according to Add Fuel.
3. Turn the fuel valve to the “ON” position.
4. After 5 minutes check the carburetor and air filter areas for any leaking
gasoline. If any leaks are found, the carburetor will need to be disassembled
and cleaned or replaced. If no gasoline leaks are found, turn the fuel valve
to the “OFF” position.
5. Check engine oil level and add clean, fresh oil if needed. See Oil
Specifications for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or cobwebs. If
necessary, clean air filter according to Cleaning the Air Filter.
7. Start the generator according to Starting the Engine.
26
100813 – 7500W ELECTRIC START GENERATOR
SPECIFICATIONS
Generator Specifications
Generator Model ……………………………………. 100813 Start Type ………………………………….. Electric,
Manual Watts (Starting/Running) ………………………… 9375/7500 AC
Volts…………………………………………….. 120/240 AC Amps @ 120 (Starting/Running) …………………
78.1/62.5 AC Amps @ 240 (Starting/Running)…………………. 39.1/31.3 Frequency
…………………………………………….. 60 Hz Phase ………………………………………………… Single Gross Weight
………………………………. 213.8 lb. (97 kg) Net Weight………………………………….. 200.6 lb. (91 kg)
Length ……………………………………… 29.9 in. (76 cm) Width …………………………………….. 27.2 in. (69.1
cm) Height……………………………………… 25.2 in. (64.1 cm)
Engine Specifications
Model ………………………………………………… FH420 Displacement ………………………………………… 420 cc
Type…………………………………………… 4-Stroke OHV Spark Plug OEM Type……………………………………………..
F6RTC Replacement Type…………………. NGK BPR6ES or equivalent Gap ……………………………
0.024-0.031 in. (0.6-0.8 mm) Valve Intake Clearance …………….. 0.004-0.006 in.
(0.10-0.15 mm) Exhaust Clearance ………….. 0.006-0.008 in. (0.15-0.20 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at
www.championpowerequipment.com.
SPECIFICATIONS
Oil Specifications
DO NOT OVERFILL. Type…………………………………….. *See following chart Capacity
………………………………………..1.2 qt. (1.1 L)
Recommended Engine Oil Type 10W-30
5W-30
10W-40
5W-30 Full Synthetic
°F -20
0
20 40 60 80 100 120
°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
Ambient temperature
NOTICE
Temperature will affect engine oil and engine performance. Change the type of
engine oil used based on temperature shown in the “Recommended Engine Oil
Type” table.
Fuel Specifications
Use regular unleaded gasoline with a minimum octane rating of 87 and an
ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT
OVERFILL.
Gasoline Capacity ……………………………. 5.7 gal. (21.5 L)
Battery Specifications
Type………………….. Rechargeable, Non-Spillable Lead Acid Volts …………………………………………….
………. 12 Capacity ………………………………………… ……. 14 Ah
Temperature Specifications
Starting Temperature Range (°F/°C) ……….. 5 to 104/-15 to 40
NOTICE
An important message about temperature: Your product is designed and rated for
continuous operation at ambient temperatures up to 40°C (104°F). When your
product is needed it may be operated at temperatures ranging from 5°F (-15°C)
to 122°F (50°C) for short periods of time. If exposed to temperatures outside
this range during storage, it should be brought back within this range before
operation. In any event, the product must always be operated outdoors, in a
wellventilated area and away from doors, windows and vents.
27
100813 – 7500W ELECTRIC START GENERATOR
TROUBLESHOOTING
TROUBLESHOOTING
Problem Generator will not start.
Cause No fuel. Faulty spark plug. Unit loaded during start up.
Generator will not start; Generator starts but runs roughly.
Generator will not start electrically.
Generator shuts down during operation.
Low oil level.
Choke in the wrong position. Spark plug wire loose. Generator battery is dead.
Battery switch is in the OFF position. Out of fuel.
Low oil level.
Generator cannot supply enough power or overheating.
Generator is overloaded. Insufficient ventilation.
No AC output. Generator gallops.
Cable not properly connected. Connected device is defective. Circuit breaker is open. Faulty brush assembly. Faulty AVR (auto voltage regulator). Loose wiring. Other. Engine governor defective.
Repeated circuit breaker tripping.
Overload. Faulty cords or device.
For further technical support:
Technical Support Team Toll Free
1-877-338-0999
support@championpowerequipment.com
Solution Add fuel. Replace spark plug. Remove load from unit. Fill crankcase to the proper level. Place generator on a flat, level surface. Adjust choke. Attach wire to spark plug. Recharge generator battery. Turn battery switch to ON position. Fill fuel tank. Fill crankcase to the proper level. Place generator on a flat, level surface. Review load and adjust. See “Connecting Electrical Loads.” Check for air restriction. Move to a well ventilated area. Check all connections. Replace defective device. Reset circuit breaker Replace brush assembly (Service Center). Replace AVR (Service Center). Inspect and tighten wiring connections. Contact the help line. Contact the help line. Review load and adjust. See “Connecting Electrical Loads.” Check for damaged, bare or frayed wires. Replace defective device.
28
100813 – 7500W ELECTRIC START GENERATOR
WARRANTY*
WARRANTY*
CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical
support please visit: https://www.championpowerequipment.com/register To
complete registration you will need to include a copy of the purchase receipt
as proof of original purchase. Proof of purchase is required for warranty
service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of
three years (parts and labor) from the original date of purchase and 270 days
(parts and labor) for commercial and industrial use. Transportation charges on
product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original
purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone
or e-mail. If the problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the defective part or
component at a CPE Service Center. CPE will provide you with a case number for
warranty service. Please keep it for future reference. Repairs or replacements
without prior authorization, or at an unauthorized repair facility, will not
be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment: Normal Wear
Products with mechanical and electrical components need periodic parts and
service to perform well. This warranty does not cover repair when normal use
has exhausted the life of a part or the equipment as a whole. Installation,
Use and Maintenance This warranty will not apply to parts and/or labor if the
product is deemed to have been misused, neglected, involved in an accident,
abused, loaded beyond the product’s limits, modified, installed improperly or
connected incorrectly to any electrical component. Normal maintenance is not
covered by this warranty and is not required to be performed at a facility or
by a person authorized by CPE.
Other Exclusions
This warranty excludes:
Cosmetic defects such as paint, decals, etc.
Wear items such as filter elements, o-rings, etc.
Accessory parts such as starting batteries, and storage covers.
Failures due to acts of God and other force majeure events beyond the
manufacturer’s control.
Problems caused by parts that are not original Champion Power Equipment
parts.
When applicable, this warranty does not apply to products used for prime power
in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time,
use of this product, freight, or any incidental or consequential claim by
anyone from using this product. THIS WARRANTY AND THE ATTACHED U.S. EPA and/or
CARB EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as an exchange will be
subject to the warranty of the original unit. The length of the warranty
governing the exchanged unit will remain calculated by reference to the
purchase date of the original unit. This warranty gives you certain legal
rights which may change from state to state or province to province. Your
state or province may also have other rights you may be entitled to that are
not listed within this warranty.
Contact Information
Address Champion Power Equipment, Inc. 12039 Smith Ave. Santa Fe Springs, CA
90670 USA www.championpowerequipment.com Customer Service Toll Free:
1-877-338-0999
info@championpowerequipment.com Fax no.:
1-562-236-9429 Technical Service Toll
Free: 1-877-338-0999
tech@championpowerequipment.com EMERGENCY 24 HOUR SUPPORT:
1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty, shall supersede the other.
29
CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and
state of California Air Resources Board (CARB) Exhaust and Evaporative
emissions regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA, California Air Resources Board, and CPE are pleased to explain the
Federal and California Exhaust and Evaporative Emission Control Systems
Warranty on your 2022 small off-road engine (SORE) and engine powered
equipment. In California, new equipment that use small off-road engines (SORE)
must be designed, built and equipped to meet the State’s stringent anti-smog
standards.
CPE must warrant the exhaust and evaporative emission control system on your
small off-road engine (SORE) for the period listed below, provided there has
been no abuse, neglect, unapproved modification, or improper maintenance of
your equipment leading to the failure of the exhaust and evaporative emission
control systems.
Your evaporative emission control system may include parts such as:
carburetors, fuel tanks, fuel lines, (for liquid fuel and fuel vapors), fuel
caps, valves, canisters, filters, clamps, connectors, and other associated
components. Also included for your exhaust emission control system may be the
fuel-injection system, the ignition system, catalytic converter and other
exhaust emission related assemblies. Where a warrantable condition exits, CPE
will repair your small off-road engine (SORE) at no cost to you including
diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE:
This exhaust and evaporative emission control system is warranted for two
years. If any exhaust and evaporative, emission related part on your engine or
equipment is defective in, the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) owner, you are responsible for the
performance of the required maintenance listed in your Owner’s Manual. CPE
recommends that you retain all your receipts covering maintenance on your
small off-road engine (SORE), but CPE cannot deny warranty coverage solely for
the lack of receipts.
As the small off-road engine (SORE) owner, you should be aware that CPE may
deny you warranty coverage if your small off-road engine (SORE) or a part has
failed due to abuse, neglect, improper maintenance or unapproved
modifications.
You are responsible for presenting your small off-road engine to an Authorized
CPE distribution center, service center or alternate service outlet as
described in (3)(f) below or CPE dealer or CPE, Santa Fe Springs, Ca. as soon
as the problem exists. The warranty repairs shall be completed in a reasonable
amount of time, not to exceed 30 days.
If you have any questions regarding your warranty coverage, you should
contact:
Champion Power Equipment, Inc. Customer Service 12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Exhaust and Evaporative
Emission Control System (ECS) Warranty Coverage.
1. APPLICABILITY: This warranty shall apply to 1995 and later model year
California small off-road engines (SORE) (for other states, 1997 and later
model year engines). The ECS Warranty Period shall begin on the date the new
engine or equipment is delivered to its original, end-use purchaser, and shall
continue for 24 consecutive months thereafter.
2. GENERAL EMISSIONS WARRANTY COVERAGE CPE warrants to the original, end-use
purchaser of the new engine or equipment and to each subsequent purchaser that
each of its small off-road engines (SORE) is:
2a. Designed, built and equipped to conform to U.S. EPA emissions standards
for spark-ignited engines at or below 19 kilowatts and all applicable
regulations adopted by the California Air Resources Board and
2b. Free from defects in materials and workmanship that cause the failure of a
warranted part to be identical in all material respects to the part as
described in the engine manufacturer’s application for certification for a
period of two years.
3. THE WARRANTY ON EXHAUST AND EVAPORATIVE EMISSION-RELATED PARTS WILL BE
INTERPRETED AS FOLLOWS:
3a. Any warranted part that is not scheduled for replacement as required
maintenance in the Owner’s Manual shall be warranted for the ECS Warranty
Period. If any such part fails during the ECS Warranty Period, it shall be
repaired or replaced by CPE according to Subsection “d” below. Any such part
repaired or replaced under the ECS Warranty shall be warranted for any
remainder of the ECS Warranty Period.
3b. Any warranted, exhaust and evaporative emissions-related part which is
scheduled only for regular inspection as specified in the Owner’s Manual shall
be warranted for the ECS Warranty Period. A statement in such written
instructions to the effect of “repair or replace as necessary”, shall not
reduce the ECS Warranty Period. Any such part repaired or replaced under the
ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
3c. Any warranted, exhaust and evaporative emissions-related part which is
scheduled for replacement as required maintenance in the Owner’s Manual shall
be warranted for the period of time prior to the first scheduled replacement
point for that part. If the part fails prior to the first scheduled
replacement, the part shall be repaired or replaced by CPE according to
Subsection “d” below. Any such exhaust and evaporative emissions-related part
repaired or replaced under the ECS Warranty, shall be warranted for the
remainder of the ECS Warranty Period prior to the first scheduled replacement
point for such emissions-related part.
3d. Repair or replacement of any warranted, exhaust and evaporative emissions-
related part under this ECS Warranty shall be performed at no charge to the
owner at a CPE Authorized Service Outlet.
3e. The owner shall not be charged for diagnostic labor which leads to the
determination that a part covered by the ECS Warranty is in fact defective,
provided that such diagnostic work is performed at a CPE Authorized Service
Outlet.
3f. CPE shall pay for covered exhaust and evaporative emissions warranty
repairs at non-authorized service outlets under the following circumstances:
i. The service is required in a population center with a population over
100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet
AND
ii.The service is required more than 100 miles from a CPE Authorized Service
Outlet. The 100 mile limitation does not apply in the following states:
Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New
Mexico, Oregon, Texas, Utah and Wyoming.
3g. CPE shall be liable for damages to other original engine components or
approved modifications proximately caused by a failure under warranty of an
emission-related part covered by the ECS Warranty.
3h. Throughout the ECS Warranty Period, CPE shall maintain a supply of
warranted exhaust and evaporative emission-related parts sufficient to meet
the expected demand for such exhaust and evaporative emission-related parts.
3i. Any CPE Authorized and approved exhaust and evaporative emission-related
replacement part may be used in the performance of any ECS Warranty
maintenance or repair and will be provided without charge to the owner. Such
use shall not reduce CPE’s warranty obligation.
3j. Unapproved add-on or modified parts may not be used to modify or repair a
CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds
for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for
failures of any warranted parts of a CPE engine caused by the use of such an
unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty
Fuel Metering System
Air Induction System Ignition System Exhaust Gas Recirculation (EGR) System
Air Injection System Catalyst or Thermal Reactor System Particulate Controls
Miscellaneous items used in Above Systems Evaporative Controls
Parts Description
Carburetor and internal parts (and/or pressure regulator or fuel injection
system), Air/fuel ratio feedback and control system, Cold start enrichment
system. Controlled hot air intake system, Intake manifold, Air filter. Spark
plug, Magneto or electronic ignition system, Spark advance/retard system. EGR
valve body, and carburetor spacer if applicable, EGR rate feedback and control
system.
Air pump or pulse valve, Valves affecting distribution of flow, Distribution
manifold. Catalytic Converter, Thermal Reactor, Exhaust Manifold.
Traps, Filters, Precipitators, and any other device used to capture
particulate emissions. Vacuum, Temperature, and time sensitive valves and
switches, Electronic Controls, Hoses, Belts, Connectors, and Assemblies. Fuel
Tank, Fuel Cap, Fuel Lines (for liquid fuel and fuel vapors), Fuel Line
Fittings, Clamps, Pressure Relief Valves, Control Valves, Control Solenoids,
Electronic Controls, Vacuum Control Diaphragms, Control Cables, Control
Linkages, Purge Valves, Gaskets, Liquid/Vapor Separator, Carbon Canister,
Canister Mounting Brackets, Carburetor Purge Port Connector.
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along
with your warranty registration card or other proof of original purchase date,
at your expense, to any Champion Power Equipment dealer who is authorized by
Champion Power Equipment, Inc. to sell and service that CPE product during his
normal business hours. Alternate service locations defined in Section (3)(f)
above must be approved by CPE prior to service. Claims for repair or
adjustment found to be caused solely by defects in material or workmanship
will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities,
or to obtain warranty service, please write or call Customer Service at
Champion Power Equipment, Inc.
Champion Power Equipment, Inc. 12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service tech@championpowerequipment.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>