Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

  • Refer to instructions
  • Indoor use only

SAFETY

  • For use with a 230V AC supply only.
  • Test before each use (see section 4).If the unit trips repeatedly, seek professional advice.
  • DO NOT allow to get wet or use in a damp atmosphere.
  • DO NOT drop or subject to shock.
  • DO NOT use if it suspected that the unit has been damaged.
  • WARNING! This RCD (residual current device) is an electrical safety device and should not be regarded as a substitute for basic electrical safety precautions

INTRODUCTION

Cuts power automatically to protect against electrocution. Suitable for all types of indoor and outdoor electrical appliances. Easy-to-use, twobutton operation. No wiring needed – plugs straight into 13A socket. No need to remove from socket to reset unit

SPECIFICATION

  • Model No : ………………………………………………….. RCD981.V2
  • Supply: …………………………………………………………………230V
  • Maximum Load : ………………………………………………….3000W
  • Maximum Operating Current: …………………………………….16A
  • Trip Speed : …………………………………………………………. 50ms
  • Trip Current : …………………………………………………………30mA

OPERATION

  • Insert the RCD adaptor into a fi xed 13A socket and then plug the portable appliance into the RCD outlet socket.
  • TESTING
  • Test the RCD before each use.
  • With the appliance connected, push the ‘Test’ button. The RCD will automatically cut the electricity supply and the indicator fl ag will show ‘off ’
  • To reconnect the electrical supply, press the ‘reset’ button. The outlet socket will be energised and the indicator fl ag will show ‘on’ (red).
  • If the RCD disconnects the electrical power at any time, remove the unit from the outlet socket and investigate the apparent fault.
  • If the RCD continues to trip, consult a competent electrician

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information

  • Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505.
  • Important: No Liability is accepted for incorrect use of this product.
  • Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
RCD981.V2 Issue : 1 21/06/21

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SEALEY User Manuals

Related Manuals