levoit D302 Humidifiers Bedroom Large Room User Manual
- June 14, 2024
- Levoit
Table of Contents
- Package Contents
- Specifications
- READ AND SAVE THESE INSTRUCTIONS SAFETY INFORMATION
- General Safety
- SAFETY INFORMATION (CONT.)
- GETTING TO KNOW YOUR HUMIDIFIER
- CONTROLS
- USING YOUR HUMIDIFIER
- CARE & MAINTENANCE
- Reassembling
- TROUBLESHOOTING
- WARRANTY INFORMATION
- CUSTOMER SUPPORT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
levoit D302 Humidifiers Bedroom Large Room User Manual
Package Contents
- 1x Ultrasonic Cool Mist Humidifier
- 2x Water Filter Sponge (1 Pre-Installed)
- 1x Cleaning Brush
- 1x User Manual
Specifications
Power Supply | AC 120V, 60Hz |
---|---|
Rated Power | 25W |
Water Tank Capacity | 3 L / 0.79 gal |
Max Runtime | Up to 25 hours on minimum mist setting Note: _The |
humidifier may run for a longer or shorter time depending on the
environmental_ temperature and humidity.
Noise Level| < 28dB
Effective Range| 10-27 m2 / 107-290 ft2
Dimensions| 18.3 x 20.6 x 29.4 cm / 7.2 x 8.1 x 11.6 in
Weight| 1.38 kg / 3 lb
READ AND SAVE THESE INSTRUCTIONS SAFETY INFORMATION
To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines.
General Safety
Only use the humidifier as described in this manual.
- Place the humidifier and cord so that it will not be knocked over. Do not place near large pieces of furniture or in high-traffic areas.
- When not in use, turn the humidifier off and disconnect from power by removing the plug from the outlet.
- Do not use the humidifier in wet
- Keep the humidifier out of reach from children.
- Do not open the base or remove the water level sensor for self-
- Always unplug your humidifier from the power outlet before cleaning your humidifier or detaching the water tank from the humidifier base.
- Always make sure to place the humidifier on a flat, level surface before operation.
- Only fill the water tank with clean Never fill the water tank with any other liquids.
- Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
- Do not place the humidifier directly on floors, carpets, or rugs.
- Do not use other items as replacement parts for this product.
- Do not cover the nozzle while the humidifier is on. Doing so may damage the humidifier.
- Remove the water tank from the base before moving the humidifier.
- Do not immerse the humidifier base, power cord, or plug in water. If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately ( see page 12).
- This humidifier is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Supervise children when they are near the humidifier.
- Children should not clean or perform maintenance on the humidifier without supervision.
- Children should be supervised to ensure that they do not play with the humidifier.
- Not for commercial use. Household use Only.
SAFETY INFORMATION (CONT.)
Caution: Risk of Leaks and Electric Shock
Do not add supplemental water treatment liquids into the water tank or base chamber. This will damage the humidifier and cause leaks.
Power & Cord
- Ensure that the plug fits properly into a polarized socket
- Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids.
- Your humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not bypass this safety feature.
- If the power supply cord is damaged, it must be replaced by Arvest Corporation or similarly qualified persons in order to avoid an electric or fire hazard. Please contact Customer Support (page 12).
GETTING TO KNOW YOUR HUMIDIFIER
- A. Nozzle
- B. Water Tank Cover
- C. Water Filter Housing
- D. Water Filter
- E. Mist Tube
- F. Water Tank
- G. Float
- H. Refill Indicator Light
- I Control Knob
- J. Base
- K. Cleaning Brush
- L. Power Cord
- M. Max Water Line (Tank)
- N. Water Outlet Valve
- O. Noise Silencer
- P. Air Outlet
- Q. Max Water Line (Base)
- R. Float Brackets
- S. Transducer
- T. Secondary Float
- U. Feet
- V. Air Inlet
CONTROLS
Control Knob
- Rotate clockwise to turn on the humidifier and to adjust the mist level.
- Rotate counterclockwise to turn off the humidifier.
N o te: There is a clicking sound when the humidifier turns on/off
Refill Indicator Light
- The red light turns on when the water tank is empty. Refill the water tank (see page 7).
- The red light turns off when the water tank is filled.
GETTING STARTED
-
Remove all packaging
-
Take the water tank off of the base and remove all tape. (Figure 1.1]
-
Rinse and reassemble all parts before first use (see Cleaning, page 8).
Note: Check to make sure that the water filter is correctly in place. If not, then rotate the filter clockwise to secure it in place. [Figure 1.2)
- Check to make sure that the float is securely in place. ( **Figure 1.3)
**
- Choose a hard, flat location for the humidifier at least 30 cm/12 inches away from any walls. The surface must be water-resistant [Figure 1.4 ]
- Mist should be directed away from walls, furniture, bedding, and appliances [Figure 1.5]
Filling & Refilling
Note: Make sure the water tank is clean before filling
-
Tum the humidifier off
-
Remove the water tank cover by holding the nozzle and pulling upward. Figure 1.6)
-
Fill the tank with room-temperature water. [ Figure 17 )
Note:
- We recommend using purified or distilled water to fill the tank
- Do not fill post the tank’s max water line
- Do not fill with hot water
CAUTION
-
Do not add water directly into the base chamber. Figure 1.8)
-
Do not add water through the mist tube. [Figure 1.9
- Replace the water tank cover
Note: Make sure the nozzle on the water tank cover is placed over the
mist tube, or the humidifier may not work correctly. (Figure 1.10 )
Filling & Refilling (cont.)
- Optionally, add 10-15 drops of essential oil into the base chamber for aromatherapy. (Figure 1.11)
Note: For best results, we recommend using Water- soluble essential oil
USING YOUR HUMIDIFIER
- Plug in the humidifier. Rotate the Control Knob clockwise to tum the humidifier on. Adjust the knob to your desired mist level. ( **Figure 2.1)
**
-
Rotate the nozzle to adjust the direction of the mist. ( Figure 2.2)
-
When your room has reached your preferred humidity level, turn the humidifier to a lower setting, or turn it off.
-
Rotate the Control Knob counterclockwise to turn the humidifier off
Note: If there is no water in the tank or the tank is removed, the humidifier will stop misting and the Refill Indicator light will turn on. Refill the tank and properly place it on the base to use your humidifier.
Important Tips
Your humidifier must have the correct level of water in the base chamber to work properly. If there is too much water in the base chamber, the humidifier cannot create mist.
- Never pour water directly into the base chamber. **(Figure 2.3)
**
-
Only add water to the water tank. The humidifier will automatically release the correct amount of water into the base chamber.
-
Avoid moving or shaking the humidifier.. [Figure 2.4 ] This may cause the water tank to release too much water into the base chamber.
-
Before moving the humidifier, turn it off, unplug it, and remove the water tank
-
If your humidifier doesn’t produce mist correctly, check the max water line to see if there is too much water in the base chamber. Pour out extra water if water is over the max line. ( **Figure 2.5)
Note: The max water line is only for this purpose. Do not pour water into
the base chamber.
**
CARE & MAINTENANCE
Note :
- All maintenance should be done on a water- resistant surface, such as a kitchen counter
- Change the water daily to avoid bacteria growth.
- Use a tissue or cloth to clean the nozzle regularly,
- If not using the humidifier for 3 days or longer, do not leave water inside. Clean and dry the humidifier instead
Cleaning
You should clean your humidifier every 3 days, and when you’re ready to store it.
Note :
- Never immerse the base in water or liquid.
- Do not use detergents to clean the humidifier
- Avoiding water or liquid going into the oar outlet when cleaning the base chamber
Cleaning (cont.)
-
Unplug the humidifier.
-
Remove and rinse the water tank cover. (Figure 3.1)
-
Remove the water tank from the base and pour out any water from the tank and base chamber. [ Figure 3.2 ]
Note: When pouring out water, hold down the float to ensure that it does not fall out of the base chamber -
Remove the water filter assembly from the tank by rotating it counterclockwise and lifting it out. ( Figure 3.3)
-
Rinse the tank, water filter assembly, and base chamber with room temperature water. [ Figure 3.4 ]
Descaling Your Humidifier
- Remove the water filter from the tank by rotating it counterclockwise and lifting it out. [Figure 3.5]
- Fill the tank with 710 mL/3 US cups of distilled white vinegar. ( **Figure 3.6)
**
-
Replace the tank cover and swish the vinegar around the tank. [Figure 3.7]
-
Place the tank on the base and soak for 15-20 minutes. Vinegar will drain into the base chamber and loosen scale (mineral buildup) in the tank and in the base chamber (including the transducer and float). [Figure 3.8]
-
Remove the tank, remove the tank cover, and pour out any vinegar, (Figure 3.9]
-
Flip the tank over and remove the noise silencer. To remove the noise silencer, press the release tabs and gently pull away from the humidifier. **(Figure 3.10)
**
-
Remove the float from the base chamber by pulling up ane end of the float ( Figure 3.11]
and pulling the shaft out from the float brackets. One side of the float brackets is open (U-shaped) to allow the shaft to be removed. [Figure 3.12 ) -
Place the float, water filter assembly, and noise silencer in a small container. Fill with enough vinegar to cover them. Soak for 15-20 minutes. [Figure 3.13]
Descaling Your Humidifier (cont.) -
Use the cleaning brush and a soft cloth to remove scale from all parts
-
Rinse all parts until any vinegar smell is completely gone. (Figure 3.14]
-
Dry all parts with a cloth. Make sure all parts are completely dry before reassembling or storing
Reassembling
- Flip the water tank over and place the noise silencer back into the tank **[Figure 3.15)
**
-
Place the water filter assembly back into the tank and rotate it clockwise to secure it in place. Figure 3.16
-
Place the float back into the base chamber.
a. Make sure the correct side of the float is facing up. [Figure 3.17]
b. Insert the smaller prong into the closed side of the float brackets. ( Figure 3.18]
c. Place the larger prong into the open (U-shaped) side of the float brackets. -
Place the tank back on the base. Refill the tank, if necessary
-
Place the tank properly on the base and place the tank cover on the water tank.
TROUBLESHOOTING
Problem | Possible Solution |
---|---|
Little or no mist comes out | Turn the mist level to a higher setting |
Fill the water tank
There may be too much water in the base chamber. Empty the base chamber.
Refill the water tank (not the base chamber) and place the water tank properly
onto the base.
Make sure the air inlet on the bottom of the base is not blocked. The
humidifier should not be set on carpet or other surfaces that may block the
air inlet.
Make sure the nozzle is not blocked or dogged,
Make sure the humidifier is on a level surface.
The water temperature may be too low. Turn the mist level to the highest
setting and let the humidifier run for a while, then adjust to the desired
setting.
If the water tank or base was washed with detergent, rinse thoroughly with
clean water to remove any detergent
Clean the water filter assembly (see page 8) or replace the filter with a new
one (see page 10).
Humidifier doesn’t turn on, or turns off unexpectedly.| Plug in the humidifier
and turn it on,
Add purified or distilled water to the water tank.
Humidifier produces an unusual smell| If the humidifier is new, unplug and
rinse all parts, then place in a cool, dry place for 12 hours.
Clean the water tank and base chamber (see Care & Maintenance, page 8).
Humidifier makes a loud or unusual noise.| Make sure the water tank is
properly in place (see Getting Started, page 7).
Set mist level to a lower setting.
Empty the base chamber Refill the water tank (not the base chamber) and place
the water tank properly onto the base.
The humidifier may be malfunctioning, Stop using the humidifier and contact
Customer Support (see page 12).
White scale (mineral buildup) appears around the humidifier| We recommend
using purified or distilled water to fill the humidifier. Avoid using water
with high mineral content
Clean the humidifier (see Care & Maintenance, page 8).
Make sure the silicone sealing ring around the water outlet valve is secure.
Avoid running the humidifier in a room with high relative humidity.
Wipe any excess water off the top and bottom of the base.
Water leaks from the humidifier.| Do not shake the humidifier.
Make sure to place the humidifier on a flat, level surface.
Check the water tank for leaks. If there are leaks, contact Customer Support
(see page 12).
Condensation forms around humidifier or windows.| Humidity may be too high.
Tum down the mist level, turn off the humidifier, or open a door or window in
the room.
Mold grows inside the humidifier| Clean the water tank and base chamber
regularly (see Care & Maintenance, page 8).
Refill Indicator Light turns on.| Fill the water tank
Place the water tank properly on the base.
Clean the water filter (see page 8) or replace it with a new one. To request a
new water filter, contact Customer Support (see page 12).
WARRANTY INFORMATION
Product | Dual 150 Ultrasonic Cool Mist Humidifier |
---|---|
Model | LUH-D302-WCA, LUH-D302-BCA |
For your own reference, we strongly recommend that you record your order ID
and date of purchase
Date of Purchase|
Order ID|
Terms & Policy
Arovast Corporation (“Arovast”) warrants this product to the original purchaser to be free from defects in material and workmanship, under normal use and conditions, for a period of 2 years from the date of original purchase.
Arovast agrees, at our option during the warranty period, to repair any defect in material or workmanship or furnish an equal product in exchange without charge, subject to verification of the defect or malfunction and proof of the date of purchase.
There is no other express warranty. This warranty does not apply:
- If the product has been modified from its original condition;
- If the product has not been used in accordance with directions and instructions in the user manual;
- To damages or defects caused by accident, abuse, misuse or improper or inadequate maintenance;
- To damages or defects caused by service or repair of the product performed by an unauthorized service provider or by anyone other than Arovast,
- To damages or defects occurring during commercial use, rental use, or any use for which the product is not intended;
- To damages or defects exceeding the cost of the product.
Arovast will not be liable for indirect, incidental, or consequential damages in connection with the use of the product covered by this warranty.
This warranty extends only to the original consumer purchaser of the product and is not transferable to any subsequent owner of the product regardless of whether the product is transferred during the specified term of the warranty.
This warranty does not extend to products purchased from unauthorized sellers. Arovast’s warranty extends only to products purchased from authorized sellers that are subject to Arovast’s quality controls and have agreed to follow its quality controls
All implied warranties are limited to the period of this limited warranty.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
If you discover that your product is defective within the specified warranty period, please contact Customer Support via support@levoit.com. DO NOT dispose of your product before contacting us. Once our Customer Support Team has approved your request, please return the product with a copy of the invoice and order ID.
This warranty is made by: Arovast Corporation 202 N. Miller St., Suite A Anaheim, CA 92806 JSA
CUSTOMER SUPPORT
If you have any questions or concerns about your new product, please contact our helpful Customer Support Team.
Arovast Corporation 1202 N. Miller St., Suite A Anaheim, CA 92806 USA
Email: support@levoit.com Toll-
Free: 888-726-8520
Support Hours
Mon-Fri, 9:00 am-5:00pm PST/PDT
*Please have your order invoice and order ID ready before contacting Customer Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>