CARRO YDC443N2L Marion 44 in Black Color Changing Indoor Flush Mount Ceiling Fan Instruction Manual
- June 14, 2024
- CARRO
Table of Contents
INSTALLATION INSTRUCTIONS
CARROHOME.COM
MANUFACTURING QUALITY
CEILING FANS SINCE FOREVER.
YDC443N2L Marion 44 in Black Color Changing Indoor Flush Mount Ceiling
Fan
This Caro Ceiling Fanniids :
| 10 Speed Options
---|---
| Forward Reverse Fan Direction
| DC Motor, stable & silent, suitable for indoor use
| Built with premium materials for durability & power
| Remote Control
SAFETY PRECAUTIONS
-
Before you begin installing the fan, shut power off at the circuit breaker of the fuse box.
-
Make sure that all electrical connections are in accordance with National Electrical Code, ANSI/NFPA 70 and local codes. Hire a licensed electrician if you are unfamiliar with installing electrical wiring.
-
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 2.1m (7 feet) from the floor and 18 inches from the tip of the blades to the wall.
-
The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds. Use only U.L. listed outlet boxes marked “Acceptable for Fan Support of 15.9 kg (35 Ibs) or less”.
-
Before and after you install the fan, make sure that all mounting components are secured to prevent the fan from falling.
-
Do not insert anything into the fan blades while the fan is operating.
-
To change the direction of the rotation of the blades, the fan must be in operation mode.
-
All set screws must be checked and retightened where necessary before installation.
-
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
-
The splices after being made should be turned upward and pushed carefully up into the outlet box. Conductor wiring identified as grounded is to be connected to a grounded conductor of power supply. Conductor wiring identified as ungrounded conductor is to be connected to an ungrounded conductor. Conductor wiring identified for equipment grounding is to be connected to an equipment- grounding conductor.
-
This device complies with part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
-
CAUTION: Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams.
-
WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or less” and use mounting screws provided with the outlet box.
-
CAUTION: To reduce the risk of injury, use only the screws provided with the outlet box in conjunction with the lock washers.
-
WARNING: To reduce the risk of personal injury, do not bend the blade bracket when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades
-
CAUTION: To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.
-
WARNING: To reduce the risk of fire or electric shock, this fan must be installed with a general use, non-dimmable, single gang, isolating wall control/switch.
-
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur, [t must be understood that common sense, caution and care are factors which cannot be built into this product. These factors must be supplied by the person (s) installing, caring for and operating the unit. -
CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair.
-
WARNING: Do not use corrosive detergents for cleaning.
Fan Diagram
Tools & Materials Required
Package Contents
Before installing, please check to make sure you have received all the
necessary components for installation.
Installation
WARNING: To avoid serious injury or death, turn off the power at the circuit breaker before installing the fan.
-
Disassemble the Light Set
Take out the light assembly from the packaging box, and then remove the lampshade by rotating counterclockwise
Fan Bucket
-
Install the Fan Bucket
2.1 Take the motor housing out of the box, use a screwdriver to loosen and remove the canopy screws and the mounting plate. Save the canopy screws for later use
2.2 Pull out the control box out of the fan bucket. 2.3 Locate 6 bucket setscrews in the hardware pack, and secure the fan bucket to the motor housing with the screws. Make sure all screws are firmly tightened
2.4 Put the control box back into the fan bucket.
Mounting Options -
Install the Mounting Plate
You have two options for mounting plate installation. Pick which one works best for your location
WARNING: Turn off the power from the breaker circuit first!
Note: For better fan performance, make sure the mounting plate is level.
Option 1: Fasten the mounting plate with the ST5x24 wood setscrews (included) when securing to the wooden ceiling beam or support structure with an approved electrical outlet box as shown in Fig 3.1.
Option 2: Use machine screws (provided with outlet box) and washers when securing to an existing ceiling fan-rated outlet box. If the mounting plate is installed at the outlet box, it should be installed on the outlet box with the screws that came with your outlet box itself.
Pull the supply wires (the black, white and ground wires) out of the outlet box and through the hole in the mounting plate and lay them to the side.
WARNING: DO NOT use the plastic outlet box. Use only U.L. listed outlet boxes marked “Acceptable for Fan Support of 15.9 kg (35 Ibs) or less”. -
Hang the Fan
Carefully lift the fan-motor assembly. Hang the motor assembly on the hook of the mounting plate by utilizing one of the holes at the outer rim of the motor housing so that it is securely suspended -
Connect the Wiring
The Green/Yellow wire from the mounting plate connects with the supply Ground wire using the wire nut.
Connect the White wire from the motor to the supply White (Neutral) wire using a wire nut.
Connect the Black wire from the motor to the supply Black/Red (Hot/Live) wire using a wire nut.
Then hide them inside the motor housing. (Make sure all the wires are connected to the correct colors as shown in Fig 5.1)
Attach the other end of safety rope to a safe place.
Note: Installing the ceiling fan with a safety rope is an extra safety feature. It secures the fan to the ceiling hook or safe place and avoids the fan from falling even in the case of material failure.
Wiring Securing the Fan -
Secure the Fan
6.1 Reinstall two of the four canopy screws (located across from each other) that were removed in step 2 to the mounting plate, but DO NOT tighten them yet.
6.2 Using both hands, lift the fan body from the hook. Align the two key slots in the top of the motor assembly with the two loosened screws on the mounting plate.
6.3 Push the fan motor assembly up and turn it counterclockwise to lock in the mounting plate. Tighten the two screws. Reinstall the other two canopy screws into the remaining two holes and tighten the four screws firmly.
WARNING: Falling fan hazard, make sure all screws are tightened to secure the fan motor assembly. -
Install the Fan Blades
7.1 Remove the blade screws from the motor head, then align two blade holes with the screw holes of the motor head and fasten blades with the blade screws as shown in Fig 7.1.
Repeat for the remaining blades.
7.2 The installation of the blades is shown in the Fig 7.2, -
Install the Light Kit
8.1 Feed the light pin wire and safety rope through the center hole of the light kit
8.2 Rotate the light kit clockwise to engage the inner thread inside the middle hole of the light kit with the outer thread of the motor shaft.
8.3 After that, one of four slots in the middle hole of the light kit should be aligned with the slot of the motor shaft so that the slot of the light kit and the slot of the motor shaft make a light kit screw hole.
8.4 Insert the light pin wire plug into the light kit terminal block. Secure the light kit screw in the hardware pack to the light kit screw hole. Make sure the screw is firmly tightened to lock the motor with the light kit.
Lampshade & Power On
-
Install the Lampshade
9.1 Align the lampshade slot with the slot of light kit, and turn it clockwise to securely lock into the light kit as shown in Fig 9.1
9.2 The lampshade installed as shown in Fig 9.2.
WARNING: To prevent SERIOUS INJURY or DEATH, make sure that the lampshade is properly secured. Allow the lampshade to cool completely before removing. -
Power On
Attis time, the ceiling fan has been installed. Turn on the power supply from the breaker circuit of the main switch or the room where the ceiling fan is installed. After the power is on, observe whether the fan light is on.
Remote Control Instructions
Pair the Remote Control to Your Fan
Power on the fan and pair the remote to the fan within 1 min. To pair remote
to fan, press and hold button for 3-5 secs to pair remote to the fan.
Successful pairing will trigger the fan light off.
Remote Control Button Definitions
Turns the fan off.
Switches between summer mode and winter mode.
-Summer mode – (Counter-clockwise)
Downward airflow creates a cooling effect.
Winter mode – (Clockwise )
An upward airflow moves warm air away from the ceiling area and redistributes
it around the living space.
Turns the fan on and decreases fan speed.
Tums the fan on and increases fan speed.
Nature Switches the fan speed between nature mode and normal mode.
Simulates a natural breeze, gentle enough not to disturb while you sleep.
Turns the lights on or off and RF pairing.
Note: Power on the fan and pair the remote to the fan within 1 min. To
pair remote tonfa, press and hold button for 3-5 secs to pair remote to the
fan. Successful pairing will trigger the fan light off.
Switches between warm light and cool light.
Press/Hold button to decrease the light intensity.
Press/Hold to button to increase the light intensify
WARNING: Do not expose the remote control to direct contact with water.
Troubleshooting
Try these troubleshooting steps before contacting Customer Service. For additional operation, maintenance, and troubleshooting information, please contact our customer service center.
SYMPTOM | POSSIBLE SOLUTION |
---|---|
Fan not spinning | 1) Make sure the fan is getting power. 2) Check your circuit |
breaker or fuse panel and wall switch for functionality. 3) Check to make sure
the fan wires are correctly connected to the house wires. 0 Remote control
must be paired with the fan within 1 minute after connecting the fan to the
electricity. 4 Use a multi-meter and test the wiring harness to see if there
is any electrical output. 5 All the pin wiring on the circuit board
must be inserted tight and in the correct position. 6 Remote needs to be
paired with the fan first. 7 Make sure the fan blades spin freely. 9 If you’re
using a wall control, check the power to the breaker from your control and try
working your ceiling fan manually. (Normal switch only for the fan power
on/off)
Fan light not working| 1 Make sure LED wires are connected to the circuit
board. 2 Make sure the whole fan is powered.
The fan is noisy and wobbling| 1. Check if the blade screws are NOT rubbing
against any part of the motor housing. 2. Check the pin wires are NOT
connected against any moving parts. 3. Check the down fan cup is NOT hitting
the motor. 4. Confirm the canopy is NOT touching the ceiling while the fan is
in operation. 5. Check the down rod is NOT slanted. 6. Tighten any loose
screws on the light kit, fan blades, motor coupling, down rod, brackets and
mounting hardware. 7. Confirm the hanger ball is firmly seated in the mounting
bracket. 8. The ceiling beam must meet the minimum tensile test strength of
30KG for installation. 9. Make sure the blades and brackets are NOT bent or
deformed. 10.Verify the wire connections are not rattling against each other.
11. Verify the fan blades are not cracked. If the fan blades are cracked,
replace the damaged blades with a new blade set from the same brand as your
ceiling fan to ensure compatibility. 12. Confirm the light kit is NOT slanting
and hitting the motor.
Unable to pair remote| 1. Check if the wires are connected in the correct
position or not. 2 Check the batteries in the remote. 3. Disconnect the power
for 10 minutes, reconnect the power and pair the remote with the fan
immediately, within 1 minute. Also try pairing.
Fan or light turning on or off by themselves| 1. Confirm the circuit breaker
is not malfunctioning. 2. Verify the wire connections are not frayed. 3. Cut
the fan power for 10 minutes then power on again. 4. All the pin wiring on the
circuit board must be inserted tight and in the correct position.
Care & Cleaning
- Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. Because of the fan’s natural movement, some connections may become loose over time. It is not necessary to remove the fan from the ceiling.
- Clean your fan periodically. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
- (Optional) Apply a light coat of furniture polish to the wood blades.
- (Optional) Cover small scratches with a light application of shoe polish.
DO NOT:
- Use water when cleaning. Water could damage the motor, or the wood, or possibly cause an electrical shock.
- Apply oil to your fan or motor. The motor has permanently lubricated sealed ball bearings.
WARNING: Power off the fan before performing maintenance or cleaning the fan.
FCC Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
Important: Please read and save these instructions before installation
Basic Product Specifications
Model | YDC443N2L-FM | Voltage | 120V |
---|---|---|---|
Fan Blade Span | 44″ | Rated Wattage | 38W(Fan 22W Lamp 16W) |
Gross Weight | 12:8lbs. | Motor RPM | 65-200rpm |
Maximum Airflow | 3480CFM | Maximum Noise | 55dB(A) |
U.S. Patent Nos.: 10,511,206 and 11,296,561.
Other Patent(s) Pending.
Questions
Have questions about our products? Contact us and talk to our helpful tech
support team.
Technical Support Business Hours:
Monday – Friday (Holidays observed).
9:00 am to 5:30 pm PST.
Tel:888-253-2374