Teleflex EU-24063-HPMSB Pressure Injectable Three-Lumen PICC Instruction Manual
- June 4, 2024
- Teleflex
Table of Contents
EU-24063-HPMSB Pressure Injectable Three-Lumen PICC
**Instruction Manual
**
Pressure Injectable Three-Lumen PICC
Contents:
1: Three Lumen Catheter: 6 Fr. (2.14 mm OD) x 40 cm, Pressure Injectable,
TPort Connector, Blue FlexTip®, Contamination Guard and Placement Wire
1: GlideThruTM Peel-Away Sheath: 6 Fr. x 2-3/4″ (7 cm) Radiopaque over 6 Fr.
Dilator
1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm)
(Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow
Advancer
1: Injection Needle: EclipseTM1 22 Ga. x 1-5/8″ (4 cm)
1: Injection Needle: EclipseTM1 25 Ga. x 1″ (2.54 cm) RW
1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
1: Filter Needle: 18 Ga. TW x 1-1/2″ (3.81 cm) with Blunt Fill Tip
2: Syringe: 10 mL Luer-Lock
1: Syringe: 3 mL Luer-Lock
1: SecondSiteTM Adjustable Hub: Fastener
1: SecondSiteTM Adjustable Hub: Catheter Clamp
1: SharpsAway® Disposal Cup
1: SharpsAway® II Locking Disposal Cup
1: Catheter Trimmer
1: Towel: 24″ x 36″ (61 cm x 91 cm)
1: Drape: 60″ x 76″ (152 cm x 193 cm)
1: Drape: 36″ x 41″ (91 cm x 104 cm) with 3″ x 5″ (8 cm x 13 cm) fenestration
1: Towel
1: Safety Scalpel: #11
1: Patient ID Card
1: Sterile Procedure Sign
1: Patient Information Booklet
1: Chart Sticker
1: PICC Line Insertion Checklist
1: Paper Tape Measure
1: Tourniquet
5: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
1: Dressing: Tegaderm®2 I.V. 4″ x 6″ (10 cm x 15.5 cm)
1: Dressing: GRIP-LOK®3 Catheter Fixation Device
10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1: Surgical Apparel: Cap
1: Surgical Apparel: Impervious Gown
1: Dressing: Steri-Strip®2 1/2″ x 4″ (1.2 cm x 10 cm)
1: Surgical Apparel: Mask
1: Surgical Apparel: Mask with Shield
1: Transducer Cover: 4-12/16″ x 95″ (12 cm x 244 cm)
3: Valve: MicroCLAVE®4 Neutral Displacement Connector
1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson, and Company.
2A registered trademark of 3M Company.
3A registered trademark of TIDI.
4A registered trademark of ICU Medical, Inc.
All components are CE 2797 unless otherwise noted.
Warning: Read all package insert warnings, precautions, and instructions
prior to use. Failure to do so may result in severe patient injury or death.
www.teleflex.com/IFU Not made with natural
rubber latex. Fluid path components are non-pyrogenic.
Contraindications: The Pressure Injectable PICC is contraindicated
wherever there is the presence of device-related infections or the presence of
thrombosis in the intended insertion vessel or catheter pathway. A clinical
assessment of the patient must be completed to ensure no contraindications
exist.
Lumen| Priming Volume*
(mL)| Gravity Flow
Rate† (mL/hr)| Pump Flow
Rate†† (mL/hr)| MAX Pressure
Injection Flow Rate** (mL/sec)
---|---|---|---|---
Distal ( 17 G a . ) Medial ( 19 G a.)
Proximal ( 19 Ga.)| 0.55
0.44
0.42| 1370
317
317| 6800
2820
2920| 6 not
rated not
rated
- Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. Pump flow rates are determined at a maximum pump pressure of 10 PSIG and represent approximate flow capabilities.
** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.
EU Authorized Representative and Importer:
7997 Teleflex Medical IDA Business and Technology Park Dublin Road,
Athlone Co. Westmeath, Ireland
Arrow International LLC Subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd.
Morrisville, NC 27560 USA
LBL056520 R00 (2021-06)
Pressure Injectable Three-Lumen PICC EU-24063-HPMSB Pressure Injectable
Three-Lumen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>