Macurco OX-6 Oxygen Monitor Gas Detection Owner’s Manual
- June 14, 2024
- MaCURCO
Table of Contents
Macurco OX-6 Oxygen Monitor Gas Detection
Product Information
- Specifications
- Product: Macurco Building & Home Solutions Cryosauna & Cryogenics
- Gas Detection: Oxygen Depletion
- Shut-Down Control: Yes
- Notification: Audio and Visual
- Oxygen Detection Activation: 19.5% O2 by volume or sooner
- Oxygen Range: 18-21 Vol %
Product Usage Instructions
- Installation
- The cryo sauna installation should include the following:
- An oxygen detection system
- The detector should be installed near the sauna cabin
- The detector should be installed in proximity to the occupant’s breathing zone
- Alarm Activation
- The alarm will activate when oxygen levels fall below the set point of 19.5% O2 by volume or sooner. The alarm provides both audio and visual notification to both the occupant and the operator.
- Effects and Symptoms of Oxygen Depletion
- The effects and symptoms of oxygen depletion are as follows:
- Oxygen Range: 11-18 Vol % – No discernible symptoms can be detected by the individual. A risk assessment must be undertaken to understand the cause and determine whether it is safe to continue working.
- Oxygen Range: 8-11 Vol % – Reduction of physical and intellectual performance without the sufferer being aware. Possibility of fainting within a few minutes without prior warning. Risk of death below 11%.
- Oxygen Range: 6-8 Vol % – Fainting occurs after a short time. Resuscitation is possible if carried out immediately.
- Oxygen Range: 0-6 Vol % – Fainting almost immediately. Brain damage even if rescued.
- FAQ
- Q: What is the activation point for the oxygen detection system?
- A: The oxygen detection system is set to activate an alarm at 19.5% O2 by volume or sooner.
- Q: Where should the oxygen detector be installed?
- A: The oxygen detector should be installed near the sauna cabin, in proximity to the occupant’s breathing zone.
- Q: What happens when oxygen levels fall below the alarm set point?
- A: The alarm will provide both audio and visual notification to notify both the occupant and the operator.
- Q: What are the effects and symptoms of oxygen depletion?
- A: The effects and symptoms vary depending on the oxygen range. In general, there may be no discernible symptoms at first, but as oxygen levels decrease, there can be a reduction in physical and intellectual performance, the possibility of fainting, and in severe cases, the risk of brain damage or death.
- Q: Is resuscitation possible when oxygen levels are very low?
- A: Resuscitation is possible if carried out immediately when oxygen levels are between 6-8 Vol %.
MODELS
Control & Notification
Fixed Gas Detection for Oxygen Depletion, Shut-Down Control & Notification
- The cryo sauna installation shall include an oxygen detection system set to activate an alarm at 19.5% O2 by volume or sooner.
- The detector should be installed near the sauna cabin, in proximity to the occupant’s breathing zone.
- The alarm shall provide both audio and visual notification to notify both the occupant and operator when oxygen levels fall below the alarm set point.
O2 (Vol %) | Effects and Symptoms |
---|---|
18-21 | **No discernible symptoms can be detected by the individual. A |
risk assessment must be undertaken to understand the cause and determine
whether it is safe to continue working.
11- 18| Reduction of physical and intellectual performance without
the sufferer being aware.
8-11| Possibility of fainting within a few minutes without prior
warning – Risk of death below 11%.
6-8| Fainting occurs after a short time. Resuscitation is possible if
carried out immediately.
0-6| Fainting almost immediately. Brain damage
even if rescued.**
- Inert cryogenic liquids like nitrogen when vaporized produce a large volume of cold inert gas displacing air causing oxygen deficiency and may accumulate in low points.
- Storage and handling of Nitrogen must meet the applicable requirements of NFPA 55, Compressed Gases and Cryogenic Fluids Code 2013.
- Customers need to consult with local and state agencies on all building, installation, and usage permitting and licensing requirements.
OX-6 Oxygen (O2) Detector, Controller & Transducer
Key Features
- Dual alarm relay (Low & high levels)
- Digital display / Onboard buzzer
- Low voltage (OX-6) 12-24AC/DC or line Voltage (OX-12) 120VAC
- Can be used standalone or connected to a burglar / fire panel, or Macurco panel
Applications
- Food Packaging
- Electronics
- Therapy chiropractors
- Fitness and athletic centers
- Hospitals / R & D laboratories
- Pharmaceuticals
Accessories
- Horn and Strobe (16 – 32 VDC only)
- PS-24 (Plugin 24VDC power)
- DVP-120 control panel
- O2 test gas