GLOBAL INDUSTRIAL 812541 Portable Power Station User Manual

June 14, 2024
GLOBAL INDUSTRIAL

GLOBAL INDUSTRIAL - logo

User’s manual
Customer Service
US: 1-800-645-2986
Portable Power Station
Model: 812541

GLOBAL INDUSTRIAL 812541 Portable Power Station -

Read the instructions carefully before use and follow the instructions pertaining to risk of fire, electric shock, or injury to persons. Keep these instructions in a safe location for future reference. For questions, visit globalindustrial.com or contact Customer Service at 1-800-645-2982

WARNINGS & PRECAUTIONS

  •  Failure to follow installation instructions will void warranty.
  • To reduce the risk of injury, close supervision is necessary when the product is used near children.
  • DO NOT put fingers or hands into the product.
  • DO NOT use a battery pack or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
  • DO NOT operate the power pack with a damaged cord or plug, or a damaged output cable.
  • DO NOT disassemble the power pack, take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock.
  • DO NOT expose a power pack to fire or excessive temperature. Exposure to fire or temperature above 130°C may cause explosion. The temperature of 130°C can be replaced by the temperature of 265°F.
  • Use of an attachment not recommended or sold by power pack manufacturer may result in a risk of fire, electric shock, or injury to persons.
  • To reduce risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the power pack.
  • To reduce the risk of electric shock, unplug the power pack form the outlet before attempting any instructed servicing.
  • When charging the internal battery, work in a well ventilated area and do not restrict ventilation in any way.
  • RISK OF EXPLOSIVE GASES To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of the battery. Review cautionary marking on these products and on engine.
  • RISK OF ELETRICAL SHOCK Never use power pack to supply power tools to cut or access to live parts or live wirings, or materials that may contain live parts or live wirings inside, such as building walls, etc.
  • Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help.Liquid ejected from the battery may cause irritation or burns.
  • Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that the safety of the product is maintained.
  • Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
  • Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery can produce a short circuit current high enough to weld a ring or the like to metal, causing a severe burn.
  • NEVER smoke or allow a spark or flame in vicinity of battery or engine.
  • GROUNDING INSTRUCTIONS This product must be grounded. If it has malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes ordinances.
  • WARNING – Improper connection of the equipment grounding conductor is able to result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
  • Different electrical appliances have different voltage standards. Before use, please carefully check whether the rated voltage range of the product is consistent with the voltage range of the portable power station, otherwise it may lead to dangerous situations.
  • After the battery is discharged to the cut-off voltage, continuing to discharge is called over-discharge. It can easily cause serious power loss of the battery, thereby greatly shortening its service life. Therefore, deep discharge should be avoided as much as possible when using the battery.
  • The product should be kept away from fire, high temperature environment, humid and rainy environment during use and storage, otherwise it may lead to dangerous situations.
  • This product has a built-in high-voltage power supply, and nonprofessionals should not disassemble it by themselves.
  • DO NOT discard the product at the end of its service life. Recycle the product according to local laws and regulations.
  • This product should be protected from rain, water immersion, and violent vibration during transportation.
  • It cannot be used at an altitude exceeding 2000m.
  • The product is AC output. Please do not insert your hands or hand-held metal conductors into the AC socket.
  • DO NOT drop, squeeze or collide with the product, so as not to subject the product to external pressure, which may cause short circuit of the internal circuit of the product and damage to the battery.
  • This product and its accessories may contain some small parts. Please keep the product and its accessories out of the reach of children. Children may accidentally damage the product and its accessories, or swallow small parts, causing suffocation or other dangers, children or people with mental retardation need to use this product accompanied by their guardians.
  • Do not use the product during thunderstorms. This may cause product failure or electric shock.
  • If the product accidentally falls into water during use, place it in a safe open area and do not turn it on again;
  • When transporting and lifting products, it is necessary to ensure that the lifting rings are tightly and firmly installed, otherwise safety accidents may occur.
  • When using the expandable battery, ensure the deviation range of the battery capacity between batteries is within 10%. Batteries of different specifications and manufacturers cannot be used; otherwise, the product may be damaged and security risks may arise.
  • Please use the charger, charging cable and photovoltaic charging interface provided with the product to charge the product, otherwise there will be security risks.
  • The product must be securely and effectively grounded before use.
  • If any fault occurs during the use of the product, it should be stopped immediately, and can be used only after the troubleshooting is complete, otherwise it will cause damage to the product.
  • The screen should be protected from collision during the application and delivery.
  • All input and output socket covers shall be closed after use.
  • DO NOT touch any of the socket connections on the product with your hands or metal devices while the device is on. Otherwise there will be a safety hazard resulting in life safety.
  • Please select solar panels according to the electrical parameters specified by the manufacturer. If the voltage is above these parameters, it may damage the product.
  • Prohibit products from using AC output loads during AC mains charging(The charging socket is 20A and can only withstand charging current). Otherwise, it will cause security risks.

Technical Parameters

Item Parameter
Nominal Power 5KW
Peak Power 10KW
Battery Parameters LiFePo4 51.2V 100AH
Battery Expansion Supports parallel expansion of up to 6 battery packs
Grid Connection No
Product Size 33.07 x 29.52 x 34.33 inch
Product Weight 305.34 lbs
Ambient Temperature Range 14 – 104°F

Relative humidity : s80% Altitudes2000 Meter
Transport and Storage Environment| Temperature: 5-131°F
Relative humidity: s93% (no condensation) Atmospheric pressure : 70kPa — 106kPa
Input| PV Charging| 120-450V 18A Support MPPT Tracking LP-20 Aviation Sockets
Mains Charging| 110-120V 60HZ 2200W 20A Triangular socket
Output| USB-A4 Output| Independent 18W Output4 : 5V3A 9V2A 12V1.5A Support QC3.0/QC2.0/AFC/FCP/BC1.2/APPLE and other fast charging protocols
USB-C2 Output| Independent 100W Output2 : 5V3A 9V3A 12V3A
15V3A 20V5A Support PPS/PD/QC3.0/QC2.0/AFC /FCP/ BC1.2/APPLE and other fast charging protocols
DC Output| 5521 interface2, cigarette lighter socket1 12V10A
AC Output| American Standard Socket L5-301 30A 125V 60HZ
AC Output| American Standard Socket TT-30R
1 30A •125V •60HZ
AC Output| American Standard Duplex Socket GFCI 5-20R*3 20A • 125V • 60HZ
Charging Time| PV charging| About 1.6H ( 4500W )
Mains charging| About 2.4H ( 2200W )
Support PV charging while discharging; do not support mains charging while discharging

Package Contents:

  • Portable power station*1
  • Product manual*1
  • Diagonal 3mm hex wrench*1
  • AC power supply charging cable*1
  • TT-30P Plug*1
  • Photovoltaic charging connector*1
  • L5-30 Plug*1
  • 17mm fork wrench*1
  • Cigarette lighter to 5521 interface connection cable*1

Application and Function Instruction:

Transform LiFePO4 DC to AC sine wave by inverter. When the product is out of power, it can be charged by mains and PV. Without Mains, this product can output AC to charge devices with corresponding power such as fridges, electric hammers, induction cookers, rice makers, fans, washing machines, TV, and air- conditioner. This product supports PV charging while discharging. Its structure meets UL2743 standards and can replace the gasoline generator for outdoor emergency work on rainy days. The product supports six expandable external batteries at maximum, reaching 35.84KWH with a more durable loaded application. This product is equipped with two 10-inch foam wheels and two 7-inch universal wheels with brakes, making it to be moved easier. At the top of the product, we designed a hook for safe lifting and handling. Besides, boxes on the top and side allow users to put tools and accessories in outdoor works. The main screen is a 7-inch high-resolution capacitance touch screen with characteristics like anti-glare, high-definition, and high sensitivity. All port covers are plastic. All output AC sockets are not only installed independently with overload and short circuit protectors but also ground fault circuit interrupter (GFCI) to protect users from security issues. Also, the product has protective functions like output overload, short circuits, and leakage. The product has the low-battery warning (when the battery capacity ≤ 20% , the battery capacity icon on the display changes to red warning tips).

Product Main Structure Composition
The portable power station is mainly composed of a metal protection frame, metal shell, PV reverse control machine, touch screen, USB/DC panel, LiFePO4 battery, and other main accessories.

Panel Function Description

  •  Front Panel
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Front
Panel

  • Rear Panel
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Rear
Panel

Panel Function Description

  • Left Door
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Left
Door

  • Right Door
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Right
Door

Display Interface Description

  •  Home Page
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Home
Page

  •  Battery Information Page
    The battery includes five status:1. Disconnected, 2. Standby: the battery is connected and standby, 3. Charging: the battery is connected and charging, 4. Discharge: the battery is connected and discharging, 5. Failure.
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Expandable
Battery Display Interface Description

  • Charging Input Page
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Charging Input
Page

  • Load Output Page
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Load Output
Page

  • Set Up Page
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Set Up
Page

  • Language Setting Page
    The product supports three language settings: English, French, Spanish (the default setting is English.)
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Language Setting
Page

  • Screen Sleep Time Page
    There are four settings for the off time: 30 seconds, 1 minute, 5 minutes, and never (the default setting is 5 minutes.)
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Screen Sleep Time
Page

  • Charging History Page
    The charging history will save the charging capacity record of the previous seven days, and display the record according to the total charging power (Ah) of each day. In that case, only the data of seven days is displayed.
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Charging History
Page

  • The Fault Icon Instructions
    Fault icons are divided into three types, high temperature, short circuit and overload. If the product is in abnormal state, the corresponding fault icon and troubleshooting prompt will appear on the screen.
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Display Interface
Description
    GLOBAL INDUSTRIAL 812541 Portable Power Station -
Output

  •  Fault Code Display
    The fault code can display four fault numbers at the same time, increasing from left to right. See Chapter 5 (Failure Code Description Table) for details about the meaning of the code.
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Fault
Code

  •  Fault History
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Fault
History

  • Fault Code Query and Troubleshooting
    GLOBAL INDUSTRIAL 812541 Portable Power Station - Fault Code Query and
Troubleshooting

Operation and Usage

  1.  Steps for the First Start of Portable Power Station
    – Turn on all circuit breaker switches at the side door.
    – Check whether there is any visible damage to the appearance of the station, and whether the output interfaces are loose or damaged (If abnormal conditions occur, stop using)
    – Fix the grounding post on the back of the station to the ground.
    – Press the “POWER” button on the front panel, and if the green light comes on, it indicates that the startup has been successful. Observe the screen to see whether the battery is fully charged. When the battery level is below 30%, it is recommended to fully
    charge it before use. When the product is powered on, the AC output defaults to on, and the DC/USB output defaults to off.

  2. Charging Steps
    – AC charging:First, confirm whether the mains grid voltage and frequency are within the range of mains charging input parameters of this product. Second, confirm that there is no load on the AC output socket, and plug one end of the AC charging cable in the accessory into the charging socket on the back of the power station, and another one end to the mains power socket. Then, check whether the charging power and remaining charging time on the screen correspond to the product parameters. During the charging process, the AC switch on the screen must be in the “ON” state, otherwise it cannot be charged.
    – Solar photovoltaic charging: Please check the photovoltaic input voltage range before charging. After confirming that the positive and negative poles of the input interface correspond correctly to the positive and negative poles on the product socket, insert the input interface into the photovoltaic charging socket at the bottom left corner of the power station. Then, turn on the POWER switch on the front panel and check if the photovoltaic charging power and remaining charging time displayed on the screen correspond to the product parameters. During the charging process, the POWER switch must be turned on, otherwise the product cannot be charged (Ensure that there is sufficient sunlight when using photovoltaic charging).
    Operation and Usage

  3. AC Output On-load Usage
    AC on load: Before use, please check that the power range and voltage range of the on-load electrical equipment should match the output parameters of the station. Press and turn on the RESET button on the GFCI5-20R socket;Check whether the breakers at the side doors are all open. Insert the power plug of the loaded product into the output socket at the front of the station, and turn on the AC switch on the front. The load should work normally. Check the output on-load power parameters on the display screen.

  4. DC/USB Output On-load Usage
    Before using the power station, please check that the voltage and the corresponding parameter range of the on-load electrical device are consistent with the power station. Insert the interface plug of the on-load electrical device into the corresponding interface in the front, and turn on the DC switch on the screen. The load should work normally. Check the output on-load power parameters on the screen.

  5. Expandable Battery Usage
    Ensure that the specifications of the expandable battery are the same as those of the main battery. When the main and the expandable battery are off, insert one end of the expandable battery cable into the battery expansion port on the rear panel of the station and the other end into the socket in the expandable battery. Then turn on the portable power station and expandable battery switch in turn. Check whether the battery status in the main display is in the normal status, and the capacity deviation range between the two batteries should be within 10% before expansion (otherwise, the battery life will be reduced and other battery failures will occur during use). The expandable battery can be charged independently by the charger equipped with the machine, or can be simultaneously charged by the mains and photovoltaic with the main battery.

Fault Code Comparison Table

Fault
Codes| Meaning| Description| Troubleshooting Methods
---|---|---|---
1| BatVoltLow| Battery under-voltage alarm| Stop Using and Charge Immediately
2| BatOverCurrSw| Battery discharge average current overcurrent software protection| Reduce the Loaded Power
3| BatOpen| Battery not connected alarm| Contact After-sales Service
4| BatlowEod| Battery under-voltage stop discharge alarm| Stop Using and Charge Immediately
5| BatOverCurrHw| Battery overcurrent hardware protection| Reduce the Loaded Power
6| BatOverVolt| Charge overvoltage protection| Stop Charging
7| BusOverVoltHw| Bus overvoltage hardware protection| Contact After-sales Service
8| BusOverVoltSw| Bus overvoltage software protection| Contact After-sales Service
9| PvVoltHigh| PV overvoltage protection| Stop Charging and Check PV Voltage
10| PvBoostOCHw| Boost overcurrent software protection| Contact After-sales Service
11| PvBoostOCHw| Boost overcurrent hardware protection| Contact After-sales Service
12| SpiCommErr| SPI communication failure between master and slave chips| Contact After-sales Service
13| OverloadBypass| Bypass overload protection| Reduce the Loaded Power
14| Overtoadlnverter| Inverter overload protection| Reduce the Loaded Power
15| AcOverCurrHw| Inverter overcurrent hardware protection| Reduce the Loaded Power
16| AuxDSpReq0ffPWM| Slave chip requests shutdown fault| Contact After-sales Service
17| InvShort| Inverter short-circuit protection| Turn off all Power and Check the Output Load and Socket
19| OverTemperMppt| PV radiator over temperature protection| Reduce Load or Turn Power off and Allow to Cool Naturally
20| OverTemperinv| Over temperature protection of inverter heat sink| Reduce Load or Turn Power off and Allow to Cool Naturally
21| FanFail| Fan failure| Contact After-sales Service
22| EEPROM| Memory failure| Contact After-sales Service
23| ModeNumErr| Model setting error| Contact After-sales Service
24| Busduff| Positive and negative bus voltage imbalance| Contact After-sales Service
25| BusShort| Bus short circuit| Contact After-sales Service
26| RlyShort| Inverted AC output backfl ow to bypass AC output| Contact After- sales Service
28| LinePhaseErr| Mains input phase error| Check Mains Charging Input Voltage
29| BusVoltLow| Bus voltage low protection| Check Mains Charging Input Voltage
30| BatCapacityLowl| Battery capacity rate below 15% alarm| Turn off, Stop Using and Charge Immediately
31| BatCapacitylow2| Battery capacity rate below 5% alarm| Turn off, Stop Using and Charge Immediately
---|---|---|---
32| BatCapacityLowStop| Battery low capacity shutdown| Turn off, Stop Using and Charge Immediately
58| BMSComErr| BMS communication failure| Contact After-sales Service
59| BMSErr| BMS error| Contact After-sales Service
60| BMSUnderTem| BMS low temperature alarm| Stop Using and Check the Ambient Temperature
61| BMSVoerTem| BMS over temperature alarm| Stop Using and Check
62| BMSOverCur| BMS overcurrent alarm| Reduce the Loaded Power
63| BMSUnderVolt| BMS under-voltage alarm| Turn off, Stop Using and Charge Immediately
64| BMSOverVolt| BMS overvoltage alarm| Stop Charging and loading to Cancel the Fault

Trouble Shooting

Issue Suggested Action
Unable to Perform Mains  Charging • If the mains input voltage range and

frequency exceed the parameter range of the power station, it cannot be charged.
• The AC switch on the screen should be in the open status. If the AC switch is closed, it c annot be charged.
• Check whether the specifications of the charging cable are consistent with those equip ped with this power station and check whether there is an open circuit.
• When charging, the AC output socket should not be plugged into the load, otherwise it cannot start charging.
Unable to Perform Photovoltaic Charging| • Check whether the voltage range and current of the photovoltaic panel are within the parameter range of the power station.
• Make sure to use it in sufficient light.
• Before PV charging, the POWER switch should be turned on so that the power station can be charged under the startup status.
• Check whether the photovoltaic circuit breaker out of the side door is on.
• Check whether the positive and negative poles of the photovoltaic panel connection line correspond to those on the product socket, and the plug and socket should match.
• Check whether the photovoltaic panel connection line is broken or on open circuit phenomenon
Unable to Perform Photovoltaic Charging| • Check whether the AC icon button in the display is open.
• The circuit breakers at the side door of the product should all be turned on.
• The RESET button on the GFCI5‐20R socket should be on and a green flashing light should indicate it.
• Confirm whether the power of the load appliance is within the normal load range of the power station.
USB/DC No‐output| • Check whether the DC icon button on the display is open.
• Check whether the load connection line is on open circuit phenomenon.
• Check if the output interface is fully inserted and firmly connected.
After turning on the main  power switch of the power  station, the product cannot start normally and  the display screen doesn’t  work| In this case, it should be considered that the product battery may be out of power, the internal reverse controller cannot be started, and the battery enters a state of power loss  sleep. You can first access the mains to charge the product and activate it. When the  battery is fully‐charged, it can be used.
Unable to Connect the Expandable Battery| • The power switch of the expandable battery should be on.
• The specifications, models and parameters of the expandable battery must be consistent with the host battery.
• Check whether the plug of the expansion connection line is completely inserted into the expansion socket.
• Measure and exclude whether the expansion line has an open circuit phenomenon.
Why does the output shut off when the battery
power is 10%?| The product is set to turn off the output when the battery power is ≤10%. This is to protect the battery cell from over‐ischarge. When this situation occurs, the battery should be charged immediately